Disturbance Observer Based on Fixed Time Sliding Mode Control and Optimal State Observer for Three-Phase Three-Level T-Type Inverters

This paper presents the advanced control method together with the disturbance rejection method with the aims to obtain the low of total harmonic distortion (THD). The expectation of the paper is that the output voltage is satisfied the requirements of the EN 62040 with the THD is less than 5&#x0...

Full description

Saved in:
Bibliographic Details
Main Authors: Anh Tuan Duong, Thanh Long Pham, Van Nam Giap, Phuong Vu
Format: Article
Language:English
Published: IEEE 2023-01-01
Series:IEEE Access
Subjects:
Online Access:https://ieeexplore.ieee.org/document/10138894/
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849737187939057664
author Anh Tuan Duong
Thanh Long Pham
Van Nam Giap
Phuong Vu
author_facet Anh Tuan Duong
Thanh Long Pham
Van Nam Giap
Phuong Vu
author_sort Anh Tuan Duong
collection DOAJ
description This paper presents the advanced control method together with the disturbance rejection method with the aims to obtain the low of total harmonic distortion (THD). The expectation of the paper is that the output voltage is satisfied the requirements of the EN 62040 with the THD is less than 5%. Therefore, this paper proposes a new disturbance observer (DOB) without the requirement of the information of the first derivative disturbance for the three phase three level (TPTL) T-type inverter system. The proposed DOB is based on the information of the measurable states, which are used such an inversed model of T-type inverter to find the information of real disturbance. First, the DOB was designed based on the given measured and estimated states. However, to design the DOB, the state observer is required. Therefore, second, the state observer (SOB) was designed based on linear matrix inequality (LMI) to identify the optimal poles of the state-tracking error function. Third, the estimated states were used to construct the fixed time (FT) sliding mode control (SMC) to control the T-type inverter system. Fourth, the Lyapunov condition was used to verify the correction of the proposed method. The performance of the proposed control strategy is validated by simulations and experiments during steady-state, transients caused by load change, and unbalanced grid conditions. The estimated states precisely tracked the measured states. The output signals precisely converged to the predefined trajectories in a predefined time and the tracking errors are small. The obtained results showed that the proposed control method provided excellent steady-state and good performances with low THD in the line currents, zero steady-state error in the output voltage, and a very fast dynamic response.
format Article
id doaj-art-a19d097c534c48d38a88b993947e5f9c
institution DOAJ
issn 2169-3536
language English
publishDate 2023-01-01
publisher IEEE
record_format Article
series IEEE Access
spelling doaj-art-a19d097c534c48d38a88b993947e5f9c2025-08-20T03:07:01ZengIEEEIEEE Access2169-35362023-01-0111620916210810.1109/ACCESS.2023.328167210138894Disturbance Observer Based on Fixed Time Sliding Mode Control and Optimal State Observer for Three-Phase Three-Level T-Type InvertersAnh Tuan Duong0Thanh Long Pham1Van Nam Giap2https://orcid.org/0000-0003-0670-874XPhuong Vu3School of Electrical and Electronic Engineering, Hanoi University of Science and Technology, Hanoi, VietnamSchool of Electrical and Electronic Engineering, Hanoi University of Science and Technology, Hanoi, VietnamSchool of Electrical and Electronic Engineering, Hanoi University of Science and Technology, Hanoi, VietnamSchool of Electrical and Electronic Engineering, Hanoi University of Science and Technology, Hanoi, VietnamThis paper presents the advanced control method together with the disturbance rejection method with the aims to obtain the low of total harmonic distortion (THD). The expectation of the paper is that the output voltage is satisfied the requirements of the EN 62040 with the THD is less than 5%. Therefore, this paper proposes a new disturbance observer (DOB) without the requirement of the information of the first derivative disturbance for the three phase three level (TPTL) T-type inverter system. The proposed DOB is based on the information of the measurable states, which are used such an inversed model of T-type inverter to find the information of real disturbance. First, the DOB was designed based on the given measured and estimated states. However, to design the DOB, the state observer is required. Therefore, second, the state observer (SOB) was designed based on linear matrix inequality (LMI) to identify the optimal poles of the state-tracking error function. Third, the estimated states were used to construct the fixed time (FT) sliding mode control (SMC) to control the T-type inverter system. Fourth, the Lyapunov condition was used to verify the correction of the proposed method. The performance of the proposed control strategy is validated by simulations and experiments during steady-state, transients caused by load change, and unbalanced grid conditions. The estimated states precisely tracked the measured states. The output signals precisely converged to the predefined trajectories in a predefined time and the tracking errors are small. The obtained results showed that the proposed control method provided excellent steady-state and good performances with low THD in the line currents, zero steady-state error in the output voltage, and a very fast dynamic response.https://ieeexplore.ieee.org/document/10138894/Three-level T-type invertersliding mode controlstate observerlinear matrix inequalitydisturbance observer
spellingShingle Anh Tuan Duong
Thanh Long Pham
Van Nam Giap
Phuong Vu
Disturbance Observer Based on Fixed Time Sliding Mode Control and Optimal State Observer for Three-Phase Three-Level T-Type Inverters
IEEE Access
Three-level T-type inverter
sliding mode control
state observer
linear matrix inequality
disturbance observer
title Disturbance Observer Based on Fixed Time Sliding Mode Control and Optimal State Observer for Three-Phase Three-Level T-Type Inverters
title_full Disturbance Observer Based on Fixed Time Sliding Mode Control and Optimal State Observer for Three-Phase Three-Level T-Type Inverters
title_fullStr Disturbance Observer Based on Fixed Time Sliding Mode Control and Optimal State Observer for Three-Phase Three-Level T-Type Inverters
title_full_unstemmed Disturbance Observer Based on Fixed Time Sliding Mode Control and Optimal State Observer for Three-Phase Three-Level T-Type Inverters
title_short Disturbance Observer Based on Fixed Time Sliding Mode Control and Optimal State Observer for Three-Phase Three-Level T-Type Inverters
title_sort disturbance observer based on fixed time sliding mode control and optimal state observer for three phase three level t type inverters
topic Three-level T-type inverter
sliding mode control
state observer
linear matrix inequality
disturbance observer
url https://ieeexplore.ieee.org/document/10138894/
work_keys_str_mv AT anhtuanduong disturbanceobserverbasedonfixedtimeslidingmodecontrolandoptimalstateobserverforthreephasethreelevelttypeinverters
AT thanhlongpham disturbanceobserverbasedonfixedtimeslidingmodecontrolandoptimalstateobserverforthreephasethreelevelttypeinverters
AT vannamgiap disturbanceobserverbasedonfixedtimeslidingmodecontrolandoptimalstateobserverforthreephasethreelevelttypeinverters
AT phuongvu disturbanceobserverbasedonfixedtimeslidingmodecontrolandoptimalstateobserverforthreephasethreelevelttypeinverters