On DIC measurements of Keff to verify if it is the FCG driving force

Redundant data obtained under quasi-constant { delta K, Kmax} loading conditions is used to verify if the effective stress intensity factor (SIF) range delta Keff delta Kmax delta Kop is indeed the fatigue crack driving force. The crack opening SIF Kop is measured along the entire crack path on DC(T...

Full description

Saved in:
Bibliographic Details
Main Authors: Jaime Tupiassú Pinho de Castro, Giancarlo Luis Gomez Gonzáles, Marco Antonio Meggiolaro, José Luiz de França Freire
Format: Article
Language:English
Published: Gruppo Italiano Frattura 2017-07-01
Series:Fracture and Structural Integrity
Subjects:
Online Access:http://www.gruppofrattura.it/pdf/rivista/numero41/numero_41_art_31.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1841564185879642112
author Jaime Tupiassú Pinho de Castro
Giancarlo Luis Gomez Gonzáles
Marco Antonio Meggiolaro
José Luiz de França Freire
author_facet Jaime Tupiassú Pinho de Castro
Giancarlo Luis Gomez Gonzáles
Marco Antonio Meggiolaro
José Luiz de França Freire
author_sort Jaime Tupiassú Pinho de Castro
collection DOAJ
description Redundant data obtained under quasi-constant { delta K, Kmax} loading conditions is used to verify if the effective stress intensity factor (SIF) range delta Keff delta Kmax delta Kop is indeed the fatigue crack driving force. The crack opening SIF Kop is measured along the entire crack path on DC(T) low carbon steel specimens by a series of strain gages bonded along the crack paths, by a strain gage bonded on their back faces, and by a digital image correlation technique. All such measurements showed a significant Kop decrease as the crack sizes increased, while the fatigue crack growth rates remained essentially constant both in the thin and thick specimens, a behavior that cannot be explained by delta Keff arguments.
format Article
id doaj-art-9ff5a31d21e241fc91e1567d807c932a
institution Kabale University
issn 1971-8993
1971-8993
language English
publishDate 2017-07-01
publisher Gruppo Italiano Frattura
record_format Article
series Fracture and Structural Integrity
spelling doaj-art-9ff5a31d21e241fc91e1567d807c932a2025-01-02T23:01:51ZengGruppo Italiano FratturaFracture and Structural Integrity1971-89931971-89932017-07-01114122723510.3221/IGF-ESIS.41.31On DIC measurements of Keff to verify if it is the FCG driving forceJaime Tupiassú Pinho de Castro0Giancarlo Luis Gomez Gonzáles1 Marco Antonio Meggiolaro2 José Luiz de França Freire 3Pontifical Catholic University of Rio de Janeiro, BrazilPontifical Catholic University of Rio de Janeiro, BrazilPontifical Catholic University of Rio de Janeiro, BrazilPontifical Catholic University of Rio de Janeiro, BrazilRedundant data obtained under quasi-constant { delta K, Kmax} loading conditions is used to verify if the effective stress intensity factor (SIF) range delta Keff delta Kmax delta Kop is indeed the fatigue crack driving force. The crack opening SIF Kop is measured along the entire crack path on DC(T) low carbon steel specimens by a series of strain gages bonded along the crack paths, by a strain gage bonded on their back faces, and by a digital image correlation technique. All such measurements showed a significant Kop decrease as the crack sizes increased, while the fatigue crack growth rates remained essentially constant both in the thin and thick specimens, a behavior that cannot be explained by delta Keff arguments.http://www.gruppofrattura.it/pdf/rivista/numero41/numero_41_art_31.pdfFatigue crack driving forcesopening load measurementsdelta Keff limitations.
spellingShingle Jaime Tupiassú Pinho de Castro
Giancarlo Luis Gomez Gonzáles
Marco Antonio Meggiolaro
José Luiz de França Freire
On DIC measurements of Keff to verify if it is the FCG driving force
Fracture and Structural Integrity
Fatigue crack driving forces
opening load measurements
delta Keff limitations.
title On DIC measurements of Keff to verify if it is the FCG driving force
title_full On DIC measurements of Keff to verify if it is the FCG driving force
title_fullStr On DIC measurements of Keff to verify if it is the FCG driving force
title_full_unstemmed On DIC measurements of Keff to verify if it is the FCG driving force
title_short On DIC measurements of Keff to verify if it is the FCG driving force
title_sort on dic measurements of keff to verify if it is the fcg driving force
topic Fatigue crack driving forces
opening load measurements
delta Keff limitations.
url http://www.gruppofrattura.it/pdf/rivista/numero41/numero_41_art_31.pdf
work_keys_str_mv AT jaimetupiassupinhodecastro ondicmeasurementsofkefftoverifyifitisthefcgdrivingforce
AT giancarloluisgomezgonzales ondicmeasurementsofkefftoverifyifitisthefcgdrivingforce
AT marcoantoniomeggiolaro ondicmeasurementsofkefftoverifyifitisthefcgdrivingforce
AT joseluizdefrancafreire ondicmeasurementsofkefftoverifyifitisthefcgdrivingforce