高层组合框架P-Δ效应的差分计算
高层组合框架在进行侧移计算时,由于其柱截面尺寸较小,应考虑其几何非线性的P—△效应的计算。本文提出了差分方法的简化方法,并与微分方法计算过程和结果进行了比较,结果说明该方法计算简捷明了,满足精度要求。