Dosimetric analysis of half-field-based VMAT with the deep inspiration breath-hold technique for left breast cancer patients following breast-conserving surgery

ObjectiveCompared the dosimetric characteristics of half-field-based VMAT and half-field-based IMRT for left breast cancer patients combined with deep inspiration breath-hold (DIBH) and free breathing (FB) techniques.MethodsTwenty-one left breast cancer patients were included. Each patient underwent...

Full description

Saved in:
Bibliographic Details
Main Authors: Weiwei Wu, Hui Yin, Zhiwei Liu, Lipeng Liu, Chengjian Xiao, Ying Xiao, Jinquan Ding, Qungui Zhang, Hailiang Guo
Format: Article
Language:English
Published: Frontiers Media S.A. 2024-11-01
Series:Frontiers in Oncology
Subjects:
Online Access:https://www.frontiersin.org/articles/10.3389/fonc.2024.1418723/full
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1846161484257689600
author Weiwei Wu
Hui Yin
Zhiwei Liu
Lipeng Liu
Chengjian Xiao
Ying Xiao
Jinquan Ding
Qungui Zhang
Hailiang Guo
author_facet Weiwei Wu
Hui Yin
Zhiwei Liu
Lipeng Liu
Chengjian Xiao
Ying Xiao
Jinquan Ding
Qungui Zhang
Hailiang Guo
author_sort Weiwei Wu
collection DOAJ
description ObjectiveCompared the dosimetric characteristics of half-field-based VMAT and half-field-based IMRT for left breast cancer patients combined with deep inspiration breath-hold (DIBH) and free breathing (FB) techniques.MethodsTwenty-one left breast cancer patients were included. Each patient underwent DIBH and FB CT scans, IMRT and VMAT plans in half-field beam mode for both breathing techniques, resulting in four plans: FB-IMRT (F-IMRT), FB-VMAT (F-VMAT), DIBH-IMRT (D-IMRT) and DIBH-VMAT (D-VMAT). The conformity index (CI), homogeneity index (HI), and the doses received at the heart, left anterior descending (LAD), left lung, right breast, and right lung, were compared among plans.The correlation between the difference in the volume of lung_L (ΔLVL) and the difference in the mean dose (ΔDmean) of lung_L under the DIBH and FB plans, the correlation between the difference in the heart-chest distance (ΔHCD) and the ΔDmean of the heart,LAD under the DIBH and FB plans.ResultsThe D-VMAT plan lower lung_L V5 than both the F-IMRT and F-VMAT plans (p<0.05), The D-VMAT plan lower values for V10, V20, V30, and Dmean than did the other plans (p < 0.05). For the heart, the D-VMAT plan lower V5, V10, V20, and Dmean values than did the other plans (p < 0.05). The D1% and Dmax of the heart and the Dmax and Dmean of the LAD obtained with the D-VMAT plan were lower than those obtained with the F-IMRT and F-VMAT plans (p < 0.05). ΔHCD exhibited correlation with the ΔDmean of the LAD between the D-VMAT and F-IMRT plans and between the D-VMAT and F-VMAT plans (R = -0.765 and -0.774, respectively, p = 0.000).Conclusionthe D-VMAT plan offered enhanced protection for OARs. The integration of the DIBH technique with half-field and VMAT technology in the D-VMAT plan offers a superior dose distribution.
format Article
id doaj-art-9e0d11c0457a4dbca47d298039e2f4ab
institution Kabale University
issn 2234-943X
language English
publishDate 2024-11-01
publisher Frontiers Media S.A.
record_format Article
series Frontiers in Oncology
spelling doaj-art-9e0d11c0457a4dbca47d298039e2f4ab2024-11-21T06:23:38ZengFrontiers Media S.A.Frontiers in Oncology2234-943X2024-11-011410.3389/fonc.2024.14187231418723Dosimetric analysis of half-field-based VMAT with the deep inspiration breath-hold technique for left breast cancer patients following breast-conserving surgeryWeiwei Wu0Hui Yin1Zhiwei Liu2Lipeng Liu3Chengjian Xiao4Ying Xiao5Jinquan Ding6Qungui Zhang7Hailiang Guo8Center of Radiation Oncology, Ganzhou Cancer Hospital, Ganzhou, Jiangxi, ChinaMedical Imaging Department, Ganzhou Cancer Hospital, Ganzhou, Jiangxi, ChinaCenter of Radiation Oncology, Ganzhou Cancer Hospital, Ganzhou, Jiangxi, ChinaCenter of Radiation Oncology, Ganzhou Cancer Hospital, Ganzhou, Jiangxi, ChinaCenter of Radiation Oncology, Ganzhou Cancer Hospital, Ganzhou, Jiangxi, ChinaCenter of Radiation Oncology, Ganzhou Cancer Hospital, Ganzhou, Jiangxi, ChinaCenter of Radiation Oncology, Ganzhou Cancer Hospital, Ganzhou, Jiangxi, ChinaCenter of Radiation Oncology, Ganzhou Cancer Hospital, Ganzhou, Jiangxi, ChinaDepartment of Oncology, the First Affiliated Hospital of Gannan Medical University, Ganzhou, Jiangxi, ChinaObjectiveCompared the dosimetric characteristics of half-field-based VMAT and half-field-based IMRT for left breast cancer patients combined with deep inspiration breath-hold (DIBH) and free breathing (FB) techniques.MethodsTwenty-one left breast cancer patients were included. Each patient underwent DIBH and FB CT scans, IMRT and VMAT plans in half-field beam mode for both breathing techniques, resulting in four plans: FB-IMRT (F-IMRT), FB-VMAT (F-VMAT), DIBH-IMRT (D-IMRT) and DIBH-VMAT (D-VMAT). The conformity index (CI), homogeneity index (HI), and the doses received at the heart, left anterior descending (LAD), left lung, right breast, and right lung, were compared among plans.The correlation between the difference in the volume of lung_L (ΔLVL) and the difference in the mean dose (ΔDmean) of lung_L under the DIBH and FB plans, the correlation between the difference in the heart-chest distance (ΔHCD) and the ΔDmean of the heart,LAD under the DIBH and FB plans.ResultsThe D-VMAT plan lower lung_L V5 than both the F-IMRT and F-VMAT plans (p<0.05), The D-VMAT plan lower values for V10, V20, V30, and Dmean than did the other plans (p < 0.05). For the heart, the D-VMAT plan lower V5, V10, V20, and Dmean values than did the other plans (p < 0.05). The D1% and Dmax of the heart and the Dmax and Dmean of the LAD obtained with the D-VMAT plan were lower than those obtained with the F-IMRT and F-VMAT plans (p < 0.05). ΔHCD exhibited correlation with the ΔDmean of the LAD between the D-VMAT and F-IMRT plans and between the D-VMAT and F-VMAT plans (R = -0.765 and -0.774, respectively, p = 0.000).Conclusionthe D-VMAT plan offered enhanced protection for OARs. The integration of the DIBH technique with half-field and VMAT technology in the D-VMAT plan offers a superior dose distribution.https://www.frontiersin.org/articles/10.3389/fonc.2024.1418723/fulldeep inspiration breath-holdinghalf beamVMATbreast cancerdosimetry
spellingShingle Weiwei Wu
Hui Yin
Zhiwei Liu
Lipeng Liu
Chengjian Xiao
Ying Xiao
Jinquan Ding
Qungui Zhang
Hailiang Guo
Dosimetric analysis of half-field-based VMAT with the deep inspiration breath-hold technique for left breast cancer patients following breast-conserving surgery
Frontiers in Oncology
deep inspiration breath-holding
half beam
VMAT
breast cancer
dosimetry
title Dosimetric analysis of half-field-based VMAT with the deep inspiration breath-hold technique for left breast cancer patients following breast-conserving surgery
title_full Dosimetric analysis of half-field-based VMAT with the deep inspiration breath-hold technique for left breast cancer patients following breast-conserving surgery
title_fullStr Dosimetric analysis of half-field-based VMAT with the deep inspiration breath-hold technique for left breast cancer patients following breast-conserving surgery
title_full_unstemmed Dosimetric analysis of half-field-based VMAT with the deep inspiration breath-hold technique for left breast cancer patients following breast-conserving surgery
title_short Dosimetric analysis of half-field-based VMAT with the deep inspiration breath-hold technique for left breast cancer patients following breast-conserving surgery
title_sort dosimetric analysis of half field based vmat with the deep inspiration breath hold technique for left breast cancer patients following breast conserving surgery
topic deep inspiration breath-holding
half beam
VMAT
breast cancer
dosimetry
url https://www.frontiersin.org/articles/10.3389/fonc.2024.1418723/full
work_keys_str_mv AT weiweiwu dosimetricanalysisofhalffieldbasedvmatwiththedeepinspirationbreathholdtechniqueforleftbreastcancerpatientsfollowingbreastconservingsurgery
AT huiyin dosimetricanalysisofhalffieldbasedvmatwiththedeepinspirationbreathholdtechniqueforleftbreastcancerpatientsfollowingbreastconservingsurgery
AT zhiweiliu dosimetricanalysisofhalffieldbasedvmatwiththedeepinspirationbreathholdtechniqueforleftbreastcancerpatientsfollowingbreastconservingsurgery
AT lipengliu dosimetricanalysisofhalffieldbasedvmatwiththedeepinspirationbreathholdtechniqueforleftbreastcancerpatientsfollowingbreastconservingsurgery
AT chengjianxiao dosimetricanalysisofhalffieldbasedvmatwiththedeepinspirationbreathholdtechniqueforleftbreastcancerpatientsfollowingbreastconservingsurgery
AT yingxiao dosimetricanalysisofhalffieldbasedvmatwiththedeepinspirationbreathholdtechniqueforleftbreastcancerpatientsfollowingbreastconservingsurgery
AT jinquanding dosimetricanalysisofhalffieldbasedvmatwiththedeepinspirationbreathholdtechniqueforleftbreastcancerpatientsfollowingbreastconservingsurgery
AT qunguizhang dosimetricanalysisofhalffieldbasedvmatwiththedeepinspirationbreathholdtechniqueforleftbreastcancerpatientsfollowingbreastconservingsurgery
AT hailiangguo dosimetricanalysisofhalffieldbasedvmatwiththedeepinspirationbreathholdtechniqueforleftbreastcancerpatientsfollowingbreastconservingsurgery