Electrochemical Detection of Pb(II) Using A Pencil Electrode with Square Wave Anodic Stripping Voltammetry Method

<p class="Abstract"><span lang="EN-US">This work describes a simple and inexpensive Pb(II) determination by a pencil electrode using the square wave anodic stripping voltammetry (SWASV) method. This research was applied using a batch cell system on 10 mL of 0.1 M acet...

Full description

Saved in:
Bibliographic Details
Main Authors: Muhammad Zamhari, Muhamad Aditya Hidayah, Gerda Pintoko Tunjungsari, Endaruji Sedyadi
Format: Article
Language:Indonesian
Published: Universitas Sultan Ageng Tirtayasa 2022-07-01
Series:EduChemia
Subjects:
Online Access:https://jurnal.untirta.ac.id/index.php/EduChemia/article/view/14756
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1846172402934874112
author Muhammad Zamhari
Muhamad Aditya Hidayah
Gerda Pintoko Tunjungsari
Endaruji Sedyadi
author_facet Muhammad Zamhari
Muhamad Aditya Hidayah
Gerda Pintoko Tunjungsari
Endaruji Sedyadi
author_sort Muhammad Zamhari
collection DOAJ
description <p class="Abstract"><span lang="EN-US">This work describes a simple and inexpensive Pb(II) determination by a pencil electrode using the square wave anodic stripping voltammetry (SWASV) method. This research was applied using a batch cell system on 10 mL of 0.1 M acetate buffer pH 4.5. The precision was performed with repeatability and reproducibility in Pb(II) concentrations of 0.</span><span lang="IN">2, </span><span lang="EN-US">0.</span><span lang="IN">4, </span><span lang="EN-US">0.</span><span lang="IN">6, </span><span lang="EN-US">and</span><span lang="EN-US">0.8</span><span lang="IN">µg mL<sup>-1</sup></span><span lang="EN-US">. Two linear ranges were obtained in the concentration of 0.1–1.0 and 2.0–8.0 µg mL<sup>-1</sup>. This method offers a detection limit of 0.07 µg mL<sup>-1</sup> and a quantification limit of 0.24 µg mL<sup>-1</sup>. The technique performed good repeatability (RSD= 7.28–9.53%) and good reproducibility (RSD=7.07–15.10%). The precisions are accepted according to the Association of Official Analytical Chemists (AOAC) standard (RSD repeatability &lt;11% and RSD reproducibility &lt;16% at a concentration of 1 µg mL<sup>-1</sup>). The method offered high operational stability up to 18 measurements (RSD=4.6%). The technique performs acceptable results with low random error in determining Pb(II).</span></p>
format Article
id doaj-art-95e8fdf148194cb5bad7f2f3c442e58a
institution Kabale University
issn 2502-4779
2502-4787
language Indonesian
publishDate 2022-07-01
publisher Universitas Sultan Ageng Tirtayasa
record_format Article
series EduChemia
spelling doaj-art-95e8fdf148194cb5bad7f2f3c442e58a2024-11-10T07:38:26ZindUniversitas Sultan Ageng TirtayasaEduChemia2502-47792502-47872022-07-017215016210.30870/educhemia.v7i2.147569607Electrochemical Detection of Pb(II) Using A Pencil Electrode with Square Wave Anodic Stripping Voltammetry MethodMuhammad Zamhari0Muhamad Aditya Hidayah1Gerda Pintoko Tunjungsari2Endaruji Sedyadi3Program Studi Pendidikan Kimia, Fakultas Ilmu Tarbiyah dan Keguruan, Universitas Islam Negeri Sunan KalijagaProgram Studi Pendidikan Kimia, Fakultas Ilmu Tarbiyah dan Keguruan, Universitas Islam Negeri Sunan KalijagaProgram Studi Pendidikan Kimia, Fakultas Ilmu Tarbiyah dan Keguruan, Universitas Islam Negeri Sunan KalijagaKimia, Fakultas Sains dan Teknologi, Universitas Islam Negeri Sunan Kalijaga<p class="Abstract"><span lang="EN-US">This work describes a simple and inexpensive Pb(II) determination by a pencil electrode using the square wave anodic stripping voltammetry (SWASV) method. This research was applied using a batch cell system on 10 mL of 0.1 M acetate buffer pH 4.5. The precision was performed with repeatability and reproducibility in Pb(II) concentrations of 0.</span><span lang="IN">2, </span><span lang="EN-US">0.</span><span lang="IN">4, </span><span lang="EN-US">0.</span><span lang="IN">6, </span><span lang="EN-US">and</span><span lang="EN-US">0.8</span><span lang="IN">µg mL<sup>-1</sup></span><span lang="EN-US">. Two linear ranges were obtained in the concentration of 0.1–1.0 and 2.0–8.0 µg mL<sup>-1</sup>. This method offers a detection limit of 0.07 µg mL<sup>-1</sup> and a quantification limit of 0.24 µg mL<sup>-1</sup>. The technique performed good repeatability (RSD= 7.28–9.53%) and good reproducibility (RSD=7.07–15.10%). The precisions are accepted according to the Association of Official Analytical Chemists (AOAC) standard (RSD repeatability &lt;11% and RSD reproducibility &lt;16% at a concentration of 1 µg mL<sup>-1</sup>). The method offered high operational stability up to 18 measurements (RSD=4.6%). The technique performs acceptable results with low random error in determining Pb(II).</span></p>https://jurnal.untirta.ac.id/index.php/EduChemia/article/view/14756pencil electrodesquare wave anodic stripping voltammetrylead
spellingShingle Muhammad Zamhari
Muhamad Aditya Hidayah
Gerda Pintoko Tunjungsari
Endaruji Sedyadi
Electrochemical Detection of Pb(II) Using A Pencil Electrode with Square Wave Anodic Stripping Voltammetry Method
EduChemia
pencil electrode
square wave anodic stripping voltammetry
lead
title Electrochemical Detection of Pb(II) Using A Pencil Electrode with Square Wave Anodic Stripping Voltammetry Method
title_full Electrochemical Detection of Pb(II) Using A Pencil Electrode with Square Wave Anodic Stripping Voltammetry Method
title_fullStr Electrochemical Detection of Pb(II) Using A Pencil Electrode with Square Wave Anodic Stripping Voltammetry Method
title_full_unstemmed Electrochemical Detection of Pb(II) Using A Pencil Electrode with Square Wave Anodic Stripping Voltammetry Method
title_short Electrochemical Detection of Pb(II) Using A Pencil Electrode with Square Wave Anodic Stripping Voltammetry Method
title_sort electrochemical detection of pb ii using a pencil electrode with square wave anodic stripping voltammetry method
topic pencil electrode
square wave anodic stripping voltammetry
lead
url https://jurnal.untirta.ac.id/index.php/EduChemia/article/view/14756
work_keys_str_mv AT muhammadzamhari electrochemicaldetectionofpbiiusingapencilelectrodewithsquarewaveanodicstrippingvoltammetrymethod
AT muhamadadityahidayah electrochemicaldetectionofpbiiusingapencilelectrodewithsquarewaveanodicstrippingvoltammetrymethod
AT gerdapintokotunjungsari electrochemicaldetectionofpbiiusingapencilelectrodewithsquarewaveanodicstrippingvoltammetrymethod
AT endarujisedyadi electrochemicaldetectionofpbiiusingapencilelectrodewithsquarewaveanodicstrippingvoltammetrymethod