Strain Energy Density as Failure Criterion for Quasi-Static Uni-axial Tensile Loading

Strain energy density is successfully used as criterion for failure assessment of brittle and quasi-brittle material behavior. This work investigates the possibility to use this method to predict the strength of V-notched specimens made of PMMA under static uniaxial tensile load. Samples are char...

Full description

Saved in:
Bibliographic Details
Main Authors: Andrea Kusch, Simone Salamina, Daniele Crivelli, Filippo Berto
Format: Article
Language:English
Published: Gruppo Italiano Frattura 2021-06-01
Series:Fracture and Structural Integrity
Subjects:
Online Access:https://www.fracturae.com/index.php/fis/article/view/3104
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1846145546845159424
author Andrea Kusch
Simone Salamina
Daniele Crivelli
Filippo Berto
author_facet Andrea Kusch
Simone Salamina
Daniele Crivelli
Filippo Berto
author_sort Andrea Kusch
collection DOAJ
description Strain energy density is successfully used as criterion for failure assessment of brittle and quasi-brittle material behavior. This work investigates the possibility to use this method to predict the strength of V-notched specimens made of PMMA under static uniaxial tensile load. Samples are characterized by a variability of notch root radii and notch opening angles. Notched specimens fail with a quasi-brittle behavior, albeit PMMA has a nonlinear stress strain curve at room temperature. The notch root radius has most influence on the strength of the specimen, whereas the angle is less relevant. The value of the strain energy density is computed by means of finite element analysis, the material is considered as linear elastic. Failure prediction, based on the critical value of the strain energy density in a well-defined volume surrounding the notch tip, show very good agreement (error <15%) with experimental data.
format Article
id doaj-art-955b0dafe620498092eb9191c9e8e3e4
institution Kabale University
issn 1971-8993
language English
publishDate 2021-06-01
publisher Gruppo Italiano Frattura
record_format Article
series Fracture and Structural Integrity
spelling doaj-art-955b0dafe620498092eb9191c9e8e3e42024-12-02T05:48:14ZengGruppo Italiano FratturaFracture and Structural Integrity1971-89932021-06-011557Strain Energy Density as Failure Criterion for Quasi-Static Uni-axial Tensile LoadingAndrea Kusch0Simone Salamina1Daniele Crivelli2Filippo Berto3University of Applied Sciences and Arts of Southern Switzerland, Lugano, SwitzerlandUniversity of Applied Sciences and Arts of Southern Switzerland, Lugano, SwitzerlandUniversity of Applied Sciences and Arts of Southern Switzerland, Lugano, SwitzerlandNorwegian University of Science and Technology, NorwayStrain energy density is successfully used as criterion for failure assessment of brittle and quasi-brittle material behavior. This work investigates the possibility to use this method to predict the strength of V-notched specimens made of PMMA under static uniaxial tensile load. Samples are characterized by a variability of notch root radii and notch opening angles. Notched specimens fail with a quasi-brittle behavior, albeit PMMA has a nonlinear stress strain curve at room temperature. The notch root radius has most influence on the strength of the specimen, whereas the angle is less relevant. The value of the strain energy density is computed by means of finite element analysis, the material is considered as linear elastic. Failure prediction, based on the critical value of the strain energy density in a well-defined volume surrounding the notch tip, show very good agreement (error <15%) with experimental data.https://www.fracturae.com/index.php/fis/article/view/3104Strain energy densityQuasi-brittle materialPMMAFailure assessment
spellingShingle Andrea Kusch
Simone Salamina
Daniele Crivelli
Filippo Berto
Strain Energy Density as Failure Criterion for Quasi-Static Uni-axial Tensile Loading
Fracture and Structural Integrity
Strain energy density
Quasi-brittle material
PMMA
Failure assessment
title Strain Energy Density as Failure Criterion for Quasi-Static Uni-axial Tensile Loading
title_full Strain Energy Density as Failure Criterion for Quasi-Static Uni-axial Tensile Loading
title_fullStr Strain Energy Density as Failure Criterion for Quasi-Static Uni-axial Tensile Loading
title_full_unstemmed Strain Energy Density as Failure Criterion for Quasi-Static Uni-axial Tensile Loading
title_short Strain Energy Density as Failure Criterion for Quasi-Static Uni-axial Tensile Loading
title_sort strain energy density as failure criterion for quasi static uni axial tensile loading
topic Strain energy density
Quasi-brittle material
PMMA
Failure assessment
url https://www.fracturae.com/index.php/fis/article/view/3104
work_keys_str_mv AT andreakusch strainenergydensityasfailurecriterionforquasistaticuniaxialtensileloading
AT simonesalamina strainenergydensityasfailurecriterionforquasistaticuniaxialtensileloading
AT danielecrivelli strainenergydensityasfailurecriterionforquasistaticuniaxialtensileloading
AT filippoberto strainenergydensityasfailurecriterionforquasistaticuniaxialtensileloading