Mechanical evaluation of mandibular fractures stabilized with absorbable implants or intraoral splints in cats

IntroductionThe goal of this cadaver study in cats was to compare the mechanical properties of intact mandibles (C) with mandibles whose simulated fracture was located between the third and fourth premolar teeth and repaired with four possible treatments: (1) Stout multiple loop interdental wiring p...

Full description

Saved in:
Bibliographic Details
Main Authors: Ana C. Castejon-Gonzalez, Chet S. Friday, Michael W. Hast, Alexander M. Reiter
Format: Article
Language:English
Published: Frontiers Media S.A. 2025-01-01
Series:Frontiers in Veterinary Science
Subjects:
Online Access:https://www.frontiersin.org/articles/10.3389/fvets.2024.1525586/full
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1841525311116673024
author Ana C. Castejon-Gonzalez
Chet S. Friday
Michael W. Hast
Michael W. Hast
Alexander M. Reiter
author_facet Ana C. Castejon-Gonzalez
Chet S. Friday
Michael W. Hast
Michael W. Hast
Alexander M. Reiter
author_sort Ana C. Castejon-Gonzalez
collection DOAJ
description IntroductionThe goal of this cadaver study in cats was to compare the mechanical properties of intact mandibles (C) with mandibles whose simulated fracture was located between the third and fourth premolar teeth and repaired with four possible treatments: (1) Stout multiple loop interdental wiring plus bis-acryl composite intraoral splint (S); (2) modified Risdon interdental wiring plus bis-acryl composite intraoral splint (R); (3) ultrasound-aided absorbable fixation plate (P); and (4) ultrasound-aided absorbable fixation mesh (M).Materials and methodsThirty feline mandibles were randomly assigned to the control and treatment groups. Mandibles were loaded by cantilever bending on the canine tooth, first in non-destructive cyclic loading followed by destructive ramp-to-failure loading.ResultsCyclic loading showed no differences between the treatment groups in angular deflection (a measure of sample flexion under non-destructive loads); however, the R group had significantly higher angular deflection than the C group. In destructive testing, no differences in mechanical properties were found between the treatment groups; however, all treatment groups demonstrated significantly lower maximum bending moment, bending stiffness, energy to failure, and maximum force when compared to the control group. The main mode of failure of the intraoral splint groups (S and R) was fracture of the bis-acryl composite (50%), and the main mode of failure of the absorbable fixation groups (P and M) was fracture of the pins (91.7%).DiscussionIntraoral splint and absorbable fixation methods have low strength and stiffness. The four treatments tested provided similar stabilization of mandibular fractures located between the third and fourth premolar teeth.
format Article
id doaj-art-952f0b87e81b46789e5c8ee3e3fee5ed
institution Kabale University
issn 2297-1769
language English
publishDate 2025-01-01
publisher Frontiers Media S.A.
record_format Article
series Frontiers in Veterinary Science
spelling doaj-art-952f0b87e81b46789e5c8ee3e3fee5ed2025-01-17T15:31:55ZengFrontiers Media S.A.Frontiers in Veterinary Science2297-17692025-01-011110.3389/fvets.2024.15255861525586Mechanical evaluation of mandibular fractures stabilized with absorbable implants or intraoral splints in catsAna C. Castejon-Gonzalez0Chet S. Friday1Michael W. Hast2Michael W. Hast3Alexander M. Reiter4Department of Clinical Sciences and Advanced Medicine, School of Veterinary Medicine, University of Pennsylvania, Philadelphia, PA, United StatesDepartment of Orthopaedic Surgery, University of Pennsylvania, Philadelphia, PA, United StatesDepartment of Orthopaedic Surgery, University of Pennsylvania, Philadelphia, PA, United StatesDepartment of Mechanical Engineering, University of Delaware, Newark, DE, United StatesDepartment of Clinical Sciences and Advanced Medicine, School of Veterinary Medicine, University of Pennsylvania, Philadelphia, PA, United StatesIntroductionThe goal of this cadaver study in cats was to compare the mechanical properties of intact mandibles (C) with mandibles whose simulated fracture was located between the third and fourth premolar teeth and repaired with four possible treatments: (1) Stout multiple loop interdental wiring plus bis-acryl composite intraoral splint (S); (2) modified Risdon interdental wiring plus bis-acryl composite intraoral splint (R); (3) ultrasound-aided absorbable fixation plate (P); and (4) ultrasound-aided absorbable fixation mesh (M).Materials and methodsThirty feline mandibles were randomly assigned to the control and treatment groups. Mandibles were loaded by cantilever bending on the canine tooth, first in non-destructive cyclic loading followed by destructive ramp-to-failure loading.ResultsCyclic loading showed no differences between the treatment groups in angular deflection (a measure of sample flexion under non-destructive loads); however, the R group had significantly higher angular deflection than the C group. In destructive testing, no differences in mechanical properties were found between the treatment groups; however, all treatment groups demonstrated significantly lower maximum bending moment, bending stiffness, energy to failure, and maximum force when compared to the control group. The main mode of failure of the intraoral splint groups (S and R) was fracture of the bis-acryl composite (50%), and the main mode of failure of the absorbable fixation groups (P and M) was fracture of the pins (91.7%).DiscussionIntraoral splint and absorbable fixation methods have low strength and stiffness. The four treatments tested provided similar stabilization of mandibular fractures located between the third and fourth premolar teeth.https://www.frontiersin.org/articles/10.3389/fvets.2024.1525586/fullfelinemandibular fractureabsorbable plateabsorbable meshmechanical testingdeflection angle
spellingShingle Ana C. Castejon-Gonzalez
Chet S. Friday
Michael W. Hast
Michael W. Hast
Alexander M. Reiter
Mechanical evaluation of mandibular fractures stabilized with absorbable implants or intraoral splints in cats
Frontiers in Veterinary Science
feline
mandibular fracture
absorbable plate
absorbable mesh
mechanical testing
deflection angle
title Mechanical evaluation of mandibular fractures stabilized with absorbable implants or intraoral splints in cats
title_full Mechanical evaluation of mandibular fractures stabilized with absorbable implants or intraoral splints in cats
title_fullStr Mechanical evaluation of mandibular fractures stabilized with absorbable implants or intraoral splints in cats
title_full_unstemmed Mechanical evaluation of mandibular fractures stabilized with absorbable implants or intraoral splints in cats
title_short Mechanical evaluation of mandibular fractures stabilized with absorbable implants or intraoral splints in cats
title_sort mechanical evaluation of mandibular fractures stabilized with absorbable implants or intraoral splints in cats
topic feline
mandibular fracture
absorbable plate
absorbable mesh
mechanical testing
deflection angle
url https://www.frontiersin.org/articles/10.3389/fvets.2024.1525586/full
work_keys_str_mv AT anaccastejongonzalez mechanicalevaluationofmandibularfracturesstabilizedwithabsorbableimplantsorintraoralsplintsincats
AT chetsfriday mechanicalevaluationofmandibularfracturesstabilizedwithabsorbableimplantsorintraoralsplintsincats
AT michaelwhast mechanicalevaluationofmandibularfracturesstabilizedwithabsorbableimplantsorintraoralsplintsincats
AT michaelwhast mechanicalevaluationofmandibularfracturesstabilizedwithabsorbableimplantsorintraoralsplintsincats
AT alexandermreiter mechanicalevaluationofmandibularfracturesstabilizedwithabsorbableimplantsorintraoralsplintsincats