Mechanical evaluation of mandibular fractures stabilized with absorbable implants or intraoral splints in cats
IntroductionThe goal of this cadaver study in cats was to compare the mechanical properties of intact mandibles (C) with mandibles whose simulated fracture was located between the third and fourth premolar teeth and repaired with four possible treatments: (1) Stout multiple loop interdental wiring p...
Saved in:
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Frontiers Media S.A.
2025-01-01
|
Series: | Frontiers in Veterinary Science |
Subjects: | |
Online Access: | https://www.frontiersin.org/articles/10.3389/fvets.2024.1525586/full |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
_version_ | 1841525311116673024 |
---|---|
author | Ana C. Castejon-Gonzalez Chet S. Friday Michael W. Hast Michael W. Hast Alexander M. Reiter |
author_facet | Ana C. Castejon-Gonzalez Chet S. Friday Michael W. Hast Michael W. Hast Alexander M. Reiter |
author_sort | Ana C. Castejon-Gonzalez |
collection | DOAJ |
description | IntroductionThe goal of this cadaver study in cats was to compare the mechanical properties of intact mandibles (C) with mandibles whose simulated fracture was located between the third and fourth premolar teeth and repaired with four possible treatments: (1) Stout multiple loop interdental wiring plus bis-acryl composite intraoral splint (S); (2) modified Risdon interdental wiring plus bis-acryl composite intraoral splint (R); (3) ultrasound-aided absorbable fixation plate (P); and (4) ultrasound-aided absorbable fixation mesh (M).Materials and methodsThirty feline mandibles were randomly assigned to the control and treatment groups. Mandibles were loaded by cantilever bending on the canine tooth, first in non-destructive cyclic loading followed by destructive ramp-to-failure loading.ResultsCyclic loading showed no differences between the treatment groups in angular deflection (a measure of sample flexion under non-destructive loads); however, the R group had significantly higher angular deflection than the C group. In destructive testing, no differences in mechanical properties were found between the treatment groups; however, all treatment groups demonstrated significantly lower maximum bending moment, bending stiffness, energy to failure, and maximum force when compared to the control group. The main mode of failure of the intraoral splint groups (S and R) was fracture of the bis-acryl composite (50%), and the main mode of failure of the absorbable fixation groups (P and M) was fracture of the pins (91.7%).DiscussionIntraoral splint and absorbable fixation methods have low strength and stiffness. The four treatments tested provided similar stabilization of mandibular fractures located between the third and fourth premolar teeth. |
format | Article |
id | doaj-art-952f0b87e81b46789e5c8ee3e3fee5ed |
institution | Kabale University |
issn | 2297-1769 |
language | English |
publishDate | 2025-01-01 |
publisher | Frontiers Media S.A. |
record_format | Article |
series | Frontiers in Veterinary Science |
spelling | doaj-art-952f0b87e81b46789e5c8ee3e3fee5ed2025-01-17T15:31:55ZengFrontiers Media S.A.Frontiers in Veterinary Science2297-17692025-01-011110.3389/fvets.2024.15255861525586Mechanical evaluation of mandibular fractures stabilized with absorbable implants or intraoral splints in catsAna C. Castejon-Gonzalez0Chet S. Friday1Michael W. Hast2Michael W. Hast3Alexander M. Reiter4Department of Clinical Sciences and Advanced Medicine, School of Veterinary Medicine, University of Pennsylvania, Philadelphia, PA, United StatesDepartment of Orthopaedic Surgery, University of Pennsylvania, Philadelphia, PA, United StatesDepartment of Orthopaedic Surgery, University of Pennsylvania, Philadelphia, PA, United StatesDepartment of Mechanical Engineering, University of Delaware, Newark, DE, United StatesDepartment of Clinical Sciences and Advanced Medicine, School of Veterinary Medicine, University of Pennsylvania, Philadelphia, PA, United StatesIntroductionThe goal of this cadaver study in cats was to compare the mechanical properties of intact mandibles (C) with mandibles whose simulated fracture was located between the third and fourth premolar teeth and repaired with four possible treatments: (1) Stout multiple loop interdental wiring plus bis-acryl composite intraoral splint (S); (2) modified Risdon interdental wiring plus bis-acryl composite intraoral splint (R); (3) ultrasound-aided absorbable fixation plate (P); and (4) ultrasound-aided absorbable fixation mesh (M).Materials and methodsThirty feline mandibles were randomly assigned to the control and treatment groups. Mandibles were loaded by cantilever bending on the canine tooth, first in non-destructive cyclic loading followed by destructive ramp-to-failure loading.ResultsCyclic loading showed no differences between the treatment groups in angular deflection (a measure of sample flexion under non-destructive loads); however, the R group had significantly higher angular deflection than the C group. In destructive testing, no differences in mechanical properties were found between the treatment groups; however, all treatment groups demonstrated significantly lower maximum bending moment, bending stiffness, energy to failure, and maximum force when compared to the control group. The main mode of failure of the intraoral splint groups (S and R) was fracture of the bis-acryl composite (50%), and the main mode of failure of the absorbable fixation groups (P and M) was fracture of the pins (91.7%).DiscussionIntraoral splint and absorbable fixation methods have low strength and stiffness. The four treatments tested provided similar stabilization of mandibular fractures located between the third and fourth premolar teeth.https://www.frontiersin.org/articles/10.3389/fvets.2024.1525586/fullfelinemandibular fractureabsorbable plateabsorbable meshmechanical testingdeflection angle |
spellingShingle | Ana C. Castejon-Gonzalez Chet S. Friday Michael W. Hast Michael W. Hast Alexander M. Reiter Mechanical evaluation of mandibular fractures stabilized with absorbable implants or intraoral splints in cats Frontiers in Veterinary Science feline mandibular fracture absorbable plate absorbable mesh mechanical testing deflection angle |
title | Mechanical evaluation of mandibular fractures stabilized with absorbable implants or intraoral splints in cats |
title_full | Mechanical evaluation of mandibular fractures stabilized with absorbable implants or intraoral splints in cats |
title_fullStr | Mechanical evaluation of mandibular fractures stabilized with absorbable implants or intraoral splints in cats |
title_full_unstemmed | Mechanical evaluation of mandibular fractures stabilized with absorbable implants or intraoral splints in cats |
title_short | Mechanical evaluation of mandibular fractures stabilized with absorbable implants or intraoral splints in cats |
title_sort | mechanical evaluation of mandibular fractures stabilized with absorbable implants or intraoral splints in cats |
topic | feline mandibular fracture absorbable plate absorbable mesh mechanical testing deflection angle |
url | https://www.frontiersin.org/articles/10.3389/fvets.2024.1525586/full |
work_keys_str_mv | AT anaccastejongonzalez mechanicalevaluationofmandibularfracturesstabilizedwithabsorbableimplantsorintraoralsplintsincats AT chetsfriday mechanicalevaluationofmandibularfracturesstabilizedwithabsorbableimplantsorintraoralsplintsincats AT michaelwhast mechanicalevaluationofmandibularfracturesstabilizedwithabsorbableimplantsorintraoralsplintsincats AT michaelwhast mechanicalevaluationofmandibularfracturesstabilizedwithabsorbableimplantsorintraoralsplintsincats AT alexandermreiter mechanicalevaluationofmandibularfracturesstabilizedwithabsorbableimplantsorintraoralsplintsincats |