Optimizing demand charge of data center base on PE method

Demand charge and energy charge are the two main components of data center electricity cost,previous re-searches have not take demand charge into consideration.PEDC algorithm was proposed by modeling time slot,work-load,service quality constraint and response time constraint.With PEDC algorithm peak...

Full description

Saved in:
Bibliographic Details
Main Authors: Yan HUANG, Peng WANG, Gao-hui XIE
Format: Article
Language:zho
Published: Editorial Department of Journal on Communications 2016-03-01
Series:Tongxin xuebao
Subjects:
Online Access:http://www.joconline.com.cn/zh/article/doi/10.11959/j.issn.1000-436x.2016056/
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1841539596489326592
author Yan HUANG
Peng WANG
Gao-hui XIE
author_facet Yan HUANG
Peng WANG
Gao-hui XIE
author_sort Yan HUANG
collection DOAJ
description Demand charge and energy charge are the two main components of data center electricity cost,previous re-searches have not take demand charge into consideration.PEDC algorithm was proposed by modeling time slot,work-load,service quality constraint and response time constraint.With PEDC algorithm peak power was decreased by partial execution on the condition of service quality constrai and response time constraint.PE method was executed in the heavy loaded time slots to reduce peak power so as to ize demand charge.Energy charge and total charge were also optimized.By comparing with four algorithms and with accurately predicted,PEDC algorithm can reduce elec-tricity cost by 5.9%~12.7% and improve cluster utilization 1.32 times.
format Article
id doaj-art-94ac251e19e04757a73f7a0e1484874f
institution Kabale University
issn 1000-436X
language zho
publishDate 2016-03-01
publisher Editorial Department of Journal on Communications
record_format Article
series Tongxin xuebao
spelling doaj-art-94ac251e19e04757a73f7a0e1484874f2025-01-14T06:55:02ZzhoEditorial Department of Journal on CommunicationsTongxin xuebao1000-436X2016-03-0137909759699784Optimizing demand charge of data center base on PE methodYan HUANGPeng WANGGao-hui XIEDemand charge and energy charge are the two main components of data center electricity cost,previous re-searches have not take demand charge into consideration.PEDC algorithm was proposed by modeling time slot,work-load,service quality constraint and response time constraint.With PEDC algorithm peak power was decreased by partial execution on the condition of service quality constrai and response time constraint.PE method was executed in the heavy loaded time slots to reduce peak power so as to ize demand charge.Energy charge and total charge were also optimized.By comparing with four algorithms and with accurately predicted,PEDC algorithm can reduce elec-tricity cost by 5.9%~12.7% and improve cluster utilization 1.32 times.http://www.joconline.com.cn/zh/article/doi/10.11959/j.issn.1000-436x.2016056/PE methoddemand chargeenergy chargeenergy cost optimization
spellingShingle Yan HUANG
Peng WANG
Gao-hui XIE
Optimizing demand charge of data center base on PE method
Tongxin xuebao
PE method
demand charge
energy charge
energy cost optimization
title Optimizing demand charge of data center base on PE method
title_full Optimizing demand charge of data center base on PE method
title_fullStr Optimizing demand charge of data center base on PE method
title_full_unstemmed Optimizing demand charge of data center base on PE method
title_short Optimizing demand charge of data center base on PE method
title_sort optimizing demand charge of data center base on pe method
topic PE method
demand charge
energy charge
energy cost optimization
url http://www.joconline.com.cn/zh/article/doi/10.11959/j.issn.1000-436x.2016056/
work_keys_str_mv AT yanhuang optimizingdemandchargeofdatacenterbaseonpemethod
AT pengwang optimizingdemandchargeofdatacenterbaseonpemethod
AT gaohuixie optimizingdemandchargeofdatacenterbaseonpemethod