Experimental Testing of Aramid Composite Applied in Ballistic Armour using Ultrasonic IR Thermography
Reference samples, in which artificial discontinuities (defects) are fabricated, are used to verify non-destructive testing procedures. Artificial discontinuities are known defects of reference samples and enable verification the possibilities of using the chosen NDT method for the identification of...
Saved in:
| Main Authors: | , |
|---|---|
| Format: | Article |
| Language: | English |
| Published: |
Military University of Technology, Warsaw
2019-06-01
|
| Series: | Problemy Mechatroniki |
| Subjects: | |
| Online Access: | http://promechjournal.pl/gicid/01.3001.0013.2117 |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
| _version_ | 1846144301291012096 |
|---|---|
| author | Monika PRACHT Waldemar ŚWIDERSKI |
| author_facet | Monika PRACHT Waldemar ŚWIDERSKI |
| author_sort | Monika PRACHT |
| collection | DOAJ |
| description | Reference samples, in which artificial discontinuities (defects) are fabricated, are used to verify non-destructive testing procedures. Artificial discontinuities are known defects of reference samples and enable verification the possibilities of using the chosen NDT method for the identification of location and depth of discontinuities. In thermographic methods the tests of reference samples also allow (helps) to determine the required thermal stimulation source parameters of the tested sample. This paper presents the results of experimental testing of defects detection in a multi-layer aramid composite used in light ballistic armour using ultrasonic infrared thermography. Samples of the aramid composite included artificial defects and were tested using different ultrasonic frequencies. The tests of the same samples were carried out with optical thermography and X-ray method and their results were compared to those determined with ultrasonic IR thermography. |
| format | Article |
| id | doaj-art-944f67c3898c473d88eea4315965d6f6 |
| institution | Kabale University |
| issn | 2081-5891 |
| language | English |
| publishDate | 2019-06-01 |
| publisher | Military University of Technology, Warsaw |
| record_format | Article |
| series | Problemy Mechatroniki |
| spelling | doaj-art-944f67c3898c473d88eea4315965d6f62024-12-02T07:56:11ZengMilitary University of Technology, WarsawProblemy Mechatroniki2081-58912019-06-01102798810.5604/01.3001.0013.211701.3001.0013.2117Experimental Testing of Aramid Composite Applied in Ballistic Armour using Ultrasonic IR ThermographyMonika PRACHT0Waldemar ŚWIDERSKI1Military Institute of Armament Technology, Zielonka, PolandMilitary Institute of Armament Technology, Zielonka, PolandReference samples, in which artificial discontinuities (defects) are fabricated, are used to verify non-destructive testing procedures. Artificial discontinuities are known defects of reference samples and enable verification the possibilities of using the chosen NDT method for the identification of location and depth of discontinuities. In thermographic methods the tests of reference samples also allow (helps) to determine the required thermal stimulation source parameters of the tested sample. This paper presents the results of experimental testing of defects detection in a multi-layer aramid composite used in light ballistic armour using ultrasonic infrared thermography. Samples of the aramid composite included artificial defects and were tested using different ultrasonic frequencies. The tests of the same samples were carried out with optical thermography and X-ray method and their results were compared to those determined with ultrasonic IR thermography.http://promechjournal.pl/gicid/01.3001.0013.2117ballistic armourIR thermographyultrasoundscomposite materials |
| spellingShingle | Monika PRACHT Waldemar ŚWIDERSKI Experimental Testing of Aramid Composite Applied in Ballistic Armour using Ultrasonic IR Thermography Problemy Mechatroniki ballistic armour IR thermography ultrasounds composite materials |
| title | Experimental Testing of Aramid Composite Applied in Ballistic Armour using Ultrasonic IR Thermography |
| title_full | Experimental Testing of Aramid Composite Applied in Ballistic Armour using Ultrasonic IR Thermography |
| title_fullStr | Experimental Testing of Aramid Composite Applied in Ballistic Armour using Ultrasonic IR Thermography |
| title_full_unstemmed | Experimental Testing of Aramid Composite Applied in Ballistic Armour using Ultrasonic IR Thermography |
| title_short | Experimental Testing of Aramid Composite Applied in Ballistic Armour using Ultrasonic IR Thermography |
| title_sort | experimental testing of aramid composite applied in ballistic armour using ultrasonic ir thermography |
| topic | ballistic armour IR thermography ultrasounds composite materials |
| url | http://promechjournal.pl/gicid/01.3001.0013.2117 |
| work_keys_str_mv | AT monikapracht experimentaltestingofaramidcompositeappliedinballisticarmourusingultrasonicirthermography AT waldemarswiderski experimentaltestingofaramidcompositeappliedinballisticarmourusingultrasonicirthermography |