Research and Experiment on Energy-Conservation Cooling Technique in IDC
Beginning with Fourier Law and dealing with centralized and dispersive heat source in server with their merits, the architecture named parallel double-channels was proposed, which consist of “contact-type”and“non-contact-type”channels with significant difference on thermal resistance, and use the “h...
Saved in:
Main Author: | |
---|---|
Format: | Article |
Language: | zho |
Published: |
Beijing Xintong Media Co., Ltd
2014-08-01
|
Series: | Dianxin kexue |
Subjects: | |
Online Access: | http://www.telecomsci.com/zh/article/doi/10.3969/j.issn.1000-0801.2014.08.017/ |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
_version_ | 1841529347910926336 |
---|---|
author | Yongshuang, Qiu Wenbo Lin Yongshuang, Qiu Wenbo Lin |
author_facet | Yongshuang, Qiu Wenbo Lin Yongshuang, Qiu Wenbo Lin |
author_sort | Yongshuang, Qiu Wenbo Lin |
collection | DOAJ |
description | Beginning with Fourier Law and dealing with centralized and dispersive heat source in server with their merits, the architecture named parallel double-channels was proposed, which consist of “contact-type”and“non-contact-type”channels with significant difference on thermal resistance, and use the “heat pipe water cooling unit + cooling tower”contact-type-cooling-channel to remove the thermal current from the key-chips in server with high efficient. The verification experiment was organized,“the customized server with double-channels-cooling”was developed, and according to the experiment result, it is feasible to realize contact-type-cooling on the CPU in servers with natural cold source. |
format | Article |
id | doaj-art-916fe51cf0e241bdb16cc7feaed3e341 |
institution | Kabale University |
issn | 1000-0801 |
language | zho |
publishDate | 2014-08-01 |
publisher | Beijing Xintong Media Co., Ltd |
record_format | Article |
series | Dianxin kexue |
spelling | doaj-art-916fe51cf0e241bdb16cc7feaed3e3412025-01-15T03:19:26ZzhoBeijing Xintong Media Co., LtdDianxin kexue1000-08012014-08-013010611159620745Research and Experiment on Energy-Conservation Cooling Technique in IDCYongshuang, Qiu Wenbo LinYongshuang, Qiu Wenbo LinBeginning with Fourier Law and dealing with centralized and dispersive heat source in server with their merits, the architecture named parallel double-channels was proposed, which consist of “contact-type”and“non-contact-type”channels with significant difference on thermal resistance, and use the “heat pipe water cooling unit + cooling tower”contact-type-cooling-channel to remove the thermal current from the key-chips in server with high efficient. The verification experiment was organized,“the customized server with double-channels-cooling”was developed, and according to the experiment result, it is feasible to realize contact-type-cooling on the CPU in servers with natural cold source.http://www.telecomsci.com/zh/article/doi/10.3969/j.issn.1000-0801.2014.08.017/double-channels-coolingheat pipewater-coolinginternet data center45℃serverCPU |
spellingShingle | Yongshuang, Qiu Wenbo Lin Yongshuang, Qiu Wenbo Lin Research and Experiment on Energy-Conservation Cooling Technique in IDC Dianxin kexue double-channels-cooling heat pipe water-cooling internet data center 45℃ server CPU |
title | Research and Experiment on Energy-Conservation Cooling Technique in IDC |
title_full | Research and Experiment on Energy-Conservation Cooling Technique in IDC |
title_fullStr | Research and Experiment on Energy-Conservation Cooling Technique in IDC |
title_full_unstemmed | Research and Experiment on Energy-Conservation Cooling Technique in IDC |
title_short | Research and Experiment on Energy-Conservation Cooling Technique in IDC |
title_sort | research and experiment on energy conservation cooling technique in idc |
topic | double-channels-cooling heat pipe water-cooling internet data center 45℃ server CPU |
url | http://www.telecomsci.com/zh/article/doi/10.3969/j.issn.1000-0801.2014.08.017/ |
work_keys_str_mv | AT yongshuangqiuwenbolin researchandexperimentonenergyconservationcoolingtechniqueinidc AT yongshuangqiuwenbolin researchandexperimentonenergyconservationcoolingtechniqueinidc |