Moderating the Soft Storey Impact in Multi-Storey Buildings: A Comparative Seismic Investigation

A storey with lateral stiffness less than 70% of the storey above or less than 80% of the average stiffness of the three storeys above is considered a soft storey. Ground-floor open-air buildings are frequently used for parking, particularly in metropolitan settings with considerable space limits. S...

Full description

Saved in:
Bibliographic Details
Main Authors: Shabla K, Chıtaranjan Pany, K.i. Praseeda
Format: Article
Language:English
Published: Yildiz Technical University 2024-12-01
Series:Journal of Sustainable Construction Materials and Technologies
Subjects:
Online Access:https://dergipark.org.tr/en/download/article-file/4467829
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1841559988020969472
author Shabla K
Chıtaranjan Pany
K.i. Praseeda
author_facet Shabla K
Chıtaranjan Pany
K.i. Praseeda
author_sort Shabla K
collection DOAJ
description A storey with lateral stiffness less than 70% of the storey above or less than 80% of the average stiffness of the three storeys above is considered a soft storey. Ground-floor open-air buildings are frequently used for parking, particularly in metropolitan settings with considerable space limits. Soft-story buildings with irregular stiffness tend to collapse more than conventional buildings. The study's main goal was to understand better the soft storey effect in multi-storey structures and how to mitigate it using strategies such as adding shear walls, bracings, viscous dampers, and stiffer columns. A G+14 storey building finite element model (FEM) has been established via ETABS software and performed Response Spectrum Analysis at three seismic zones-III, IV and V. To determine the best method for reducing the soft storey effect in buildings, an analysis is conducted taking into account many parameters, including storey shear, stiffness, storey drift, and storey displacement for the entire structure, as well as the responses at the soft storey level for different configurations. According to the findings, adding a shear wall to a soft-storey building increases storey shear while reducing maximum displacement and storey drift. The first floor of the structure (soft storey) exhibits the most significant reduction in displacement (79.29%) and storey drift (79.3%) when shear walls are incorporated at the corners. There is also a 33.11% increase in base shear at the first story level, and the structure's stiffness increases by 6.5 times compared to a soft storey building. Adding a shear wall reduces the soft storey building's maximum displacement and storey drift by 25.27% and 59.28%, respectively. The soft storey building's maximum storey shear rises by 33.38%. Regarding seismic performance, a soft-storey building with a shear wall performs better than other soft-storey mitigation techniques.
format Article
id doaj-art-8ed932460b694503bdb5bead962a5ab9
institution Kabale University
issn 2458-973X
language English
publishDate 2024-12-01
publisher Yildiz Technical University
record_format Article
series Journal of Sustainable Construction Materials and Technologies
spelling doaj-art-8ed932460b694503bdb5bead962a5ab92025-01-05T06:44:27ZengYildiz Technical UniversityJournal of Sustainable Construction Materials and Technologies2458-973X2024-12-019435536410.47481/jscmt.1607472252Moderating the Soft Storey Impact in Multi-Storey Buildings: A Comparative Seismic InvestigationShabla K0https://orcid.org/0009-0003-7627-2352Chıtaranjan Pany1https://orcid.org/0000-0001-8617-2134K.i. Praseeda2https://orcid.org/0000-0002-4980-403XDepartment of Civil Engineering, NSS College of Engineering PalakkadVikram Sarabhai Space Centre, Structural EngineeringDepartment of Civil Engineering, NSS College of Engineering PalakkadA storey with lateral stiffness less than 70% of the storey above or less than 80% of the average stiffness of the three storeys above is considered a soft storey. Ground-floor open-air buildings are frequently used for parking, particularly in metropolitan settings with considerable space limits. Soft-story buildings with irregular stiffness tend to collapse more than conventional buildings. The study's main goal was to understand better the soft storey effect in multi-storey structures and how to mitigate it using strategies such as adding shear walls, bracings, viscous dampers, and stiffer columns. A G+14 storey building finite element model (FEM) has been established via ETABS software and performed Response Spectrum Analysis at three seismic zones-III, IV and V. To determine the best method for reducing the soft storey effect in buildings, an analysis is conducted taking into account many parameters, including storey shear, stiffness, storey drift, and storey displacement for the entire structure, as well as the responses at the soft storey level for different configurations. According to the findings, adding a shear wall to a soft-storey building increases storey shear while reducing maximum displacement and storey drift. The first floor of the structure (soft storey) exhibits the most significant reduction in displacement (79.29%) and storey drift (79.3%) when shear walls are incorporated at the corners. There is also a 33.11% increase in base shear at the first story level, and the structure's stiffness increases by 6.5 times compared to a soft storey building. Adding a shear wall reduces the soft storey building's maximum displacement and storey drift by 25.27% and 59.28%, respectively. The soft storey building's maximum storey shear rises by 33.38%. Regarding seismic performance, a soft-storey building with a shear wall performs better than other soft-storey mitigation techniques.https://dergipark.org.tr/en/download/article-file/4467829bracingsresponse spectrumanalysisshear wallsoft storeystiffer columnsviscous damper
spellingShingle Shabla K
Chıtaranjan Pany
K.i. Praseeda
Moderating the Soft Storey Impact in Multi-Storey Buildings: A Comparative Seismic Investigation
Journal of Sustainable Construction Materials and Technologies
bracings
response spectrumanalysis
shear wall
soft storey
stiffer columns
viscous damper
title Moderating the Soft Storey Impact in Multi-Storey Buildings: A Comparative Seismic Investigation
title_full Moderating the Soft Storey Impact in Multi-Storey Buildings: A Comparative Seismic Investigation
title_fullStr Moderating the Soft Storey Impact in Multi-Storey Buildings: A Comparative Seismic Investigation
title_full_unstemmed Moderating the Soft Storey Impact in Multi-Storey Buildings: A Comparative Seismic Investigation
title_short Moderating the Soft Storey Impact in Multi-Storey Buildings: A Comparative Seismic Investigation
title_sort moderating the soft storey impact in multi storey buildings a comparative seismic investigation
topic bracings
response spectrumanalysis
shear wall
soft storey
stiffer columns
viscous damper
url https://dergipark.org.tr/en/download/article-file/4467829
work_keys_str_mv AT shablak moderatingthesoftstoreyimpactinmultistoreybuildingsacomparativeseismicinvestigation
AT chıtaranjanpany moderatingthesoftstoreyimpactinmultistoreybuildingsacomparativeseismicinvestigation
AT kipraseeda moderatingthesoftstoreyimpactinmultistoreybuildingsacomparativeseismicinvestigation