Research on IGBT Half-bridge Resonant Inverter

Using laser sweep frequency to start during series type IGBT half-bridge inverter working, the frequency reduces from 4000Hz gradually, and when the load frequency is lower than the natural resonant frequency, the inverter will be short-circuited in the state of capacitive working, which will destro...

Full description

Saved in:
Bibliographic Details
Main Authors: QI Xingkun, CAO Chungang
Format: Article
Language:zho
Published: Editorial Office of Control and Information Technology 2013-01-01
Series:Kongzhi Yu Xinxi Jishu
Subjects:
Online Access:http://ctet.csrzic.com/thesisDetails#10.13889/j.issn.2095-3631.2013.01.004
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849224741309644800
author QI Xingkun
CAO Chungang
author_facet QI Xingkun
CAO Chungang
author_sort QI Xingkun
collection DOAJ
description Using laser sweep frequency to start during series type IGBT half-bridge inverter working, the frequency reduces from 4000Hz gradually, and when the load frequency is lower than the natural resonant frequency, the inverter will be short-circuited in the state of capacitive working, which will destroy the equipment. In order to avoid this event, a phase-locked loop control circuit was designed to ensure the inverter work in the emotional state,when the operating frequency was close to resonance frequency, the frequency would be locked in quasi-resonant state. Matlab / Simulink software is used to build simulation models to verify correctness of the design. Finally, the feasibility of the design is verified through prototype experiment, and the test results are analyzed.
format Article
id doaj-art-894d90419d184f0da7e117ba5e983e45
institution Kabale University
issn 2096-5427
language zho
publishDate 2013-01-01
publisher Editorial Office of Control and Information Technology
record_format Article
series Kongzhi Yu Xinxi Jishu
spelling doaj-art-894d90419d184f0da7e117ba5e983e452025-08-25T06:55:50ZzhoEditorial Office of Control and Information TechnologyKongzhi Yu Xinxi Jishu2096-54272013-01-0130121582335294Research on IGBT Half-bridge Resonant InverterQI XingkunCAO ChungangUsing laser sweep frequency to start during series type IGBT half-bridge inverter working, the frequency reduces from 4000Hz gradually, and when the load frequency is lower than the natural resonant frequency, the inverter will be short-circuited in the state of capacitive working, which will destroy the equipment. In order to avoid this event, a phase-locked loop control circuit was designed to ensure the inverter work in the emotional state,when the operating frequency was close to resonance frequency, the frequency would be locked in quasi-resonant state. Matlab / Simulink software is used to build simulation models to verify correctness of the design. Finally, the feasibility of the design is verified through prototype experiment, and the test results are analyzed.http://ctet.csrzic.com/thesisDetails#10.13889/j.issn.2095-3631.2013.01.004half-bridge inverterPLLfrequency controlIGBT
spellingShingle QI Xingkun
CAO Chungang
Research on IGBT Half-bridge Resonant Inverter
Kongzhi Yu Xinxi Jishu
half-bridge inverter
PLL
frequency control
IGBT
title Research on IGBT Half-bridge Resonant Inverter
title_full Research on IGBT Half-bridge Resonant Inverter
title_fullStr Research on IGBT Half-bridge Resonant Inverter
title_full_unstemmed Research on IGBT Half-bridge Resonant Inverter
title_short Research on IGBT Half-bridge Resonant Inverter
title_sort research on igbt half bridge resonant inverter
topic half-bridge inverter
PLL
frequency control
IGBT
url http://ctet.csrzic.com/thesisDetails#10.13889/j.issn.2095-3631.2013.01.004
work_keys_str_mv AT qixingkun researchonigbthalfbridgeresonantinverter
AT caochungang researchonigbthalfbridgeresonantinverter