Research on IGBT Half-bridge Resonant Inverter

Using laser sweep frequency to start during series type IGBT half-bridge inverter working, the frequency reduces from 4000Hz gradually, and when the load frequency is lower than the natural resonant frequency, the inverter will be short-circuited in the state of capacitive working, which will destro...

Full description

Saved in:
Bibliographic Details
Main Authors: QI Xingkun, CAO Chungang
Format: Article
Language:zho
Published: Editorial Office of Control and Information Technology 2013-01-01
Series:Kongzhi Yu Xinxi Jishu
Subjects:
Online Access:http://ctet.csrzic.com/thesisDetails#10.13889/j.issn.2095-3631.2013.01.004
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Using laser sweep frequency to start during series type IGBT half-bridge inverter working, the frequency reduces from 4000Hz gradually, and when the load frequency is lower than the natural resonant frequency, the inverter will be short-circuited in the state of capacitive working, which will destroy the equipment. In order to avoid this event, a phase-locked loop control circuit was designed to ensure the inverter work in the emotional state,when the operating frequency was close to resonance frequency, the frequency would be locked in quasi-resonant state. Matlab / Simulink software is used to build simulation models to verify correctness of the design. Finally, the feasibility of the design is verified through prototype experiment, and the test results are analyzed.
ISSN:2096-5427