Comparison of Adaptation and Microleakage of CAD/CAM Restorations to Inlay Cavities Prepared by Using Different Finishing Methods

Purpose: To compare the adaptation and microleakage of CAD/CAM inlay restorations using conventional or ultrasonic finishing equipment and their combinations.Materials & Methods: Inlay cavities were prepared on 66 extracted human lower first molar teeth using one of...

Full description

Saved in:
Bibliographic Details
Main Authors: Ayben Şentürk, Mehmet Ali Kılıçarslan, Merve Çakırbay Tanış, Mert Ocak, İbrahim Berk Bellaz
Format: Article
Language:English
Published: Ankara University 2024-12-01
Series:European Annals of Dental Sciences
Online Access:https://dergipark.org.tr/en/doi/10.52037/eads.2024.0020
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1841525468478570496
author Ayben Şentürk
Mehmet Ali Kılıçarslan
Merve Çakırbay Tanış
Mert Ocak
İbrahim Berk Bellaz
author_facet Ayben Şentürk
Mehmet Ali Kılıçarslan
Merve Çakırbay Tanış
Mert Ocak
İbrahim Berk Bellaz
author_sort Ayben Şentürk
collection DOAJ
description Purpose: To compare the adaptation and microleakage of CAD/CAM inlay restorations using conventional or ultrasonic finishing equipment and their combinations.Materials & Methods: Inlay cavities were prepared on 66 extracted human lower first molar teeth using one of the following finishing methods: Group I: straight fissure diamond bur; Group II: fissure diamond bur and ultrasonic tip; Group III: 6º tapered conical diamond bur; Group IV: 6º tapered conical diamond bur and ultrasonic tip. Inlay restorations milled from feldspathic ceramic blocks were cemented with resin cement. Adaptation and microleakage of the restorations were evaluated by micro-CT. The adaptation of the restorations was evaluated in four areas and five determined points. The differences between the finishing methods were statistically evaluated at each measurement point.Results: The adaptation of the restorations differed between 1.07 and 330.71 µm. Statistical differences were observed in the marginal and internal adaptation of ceramic inlay restorations due to the finishing method used at some points of the ceramic and cavity interface. However, the microleakage values between the finishing methods did not show a statistical difference.Conclusion: According to the results of this study, the microleakage of the ceramic inlay restorations is not affected by the finishing method used. However, the adaptation of the restoration could be affected by the finishing method, depending on the area.Clinical Significance: Preparations for inlay restorations prepared with these special burrs and ultrasonic instruments created better marginal fit, which could result in more successful ceramic inlays.
format Article
id doaj-art-87ef35ac1e504ccbaad1b8307912426c
institution Kabale University
issn 2757-6744
language English
publishDate 2024-12-01
publisher Ankara University
record_format Article
series European Annals of Dental Sciences
spelling doaj-art-87ef35ac1e504ccbaad1b8307912426c2025-01-17T11:30:51ZengAnkara UniversityEuropean Annals of Dental Sciences2757-67442024-12-0151312112710.52037/eads.2024.0020 Comparison of Adaptation and Microleakage of CAD/CAM Restorations to Inlay Cavities Prepared by Using Different Finishing Methods Ayben Şentürk0https://orcid.org/0000-0002-1096-4810Mehmet Ali Kılıçarslan1https://orcid.org/0000-0002-8619-957XMerve Çakırbay Tanış2https://orcid.org/0000-0001-5698-8220Mert Ocak3İbrahim Berk Bellaz4https://orcid.org/0000-0001-5006-7893ANKARA UNIVERSITY, FACULTY OF DENTISTRY, DENTISTRY PR.ANKARA UNIVERSITY, FACULTY OF DENTISTRY, DENTISTRY PR.GAZI UNIVERSITY, FACULTY OF DENTISTRY, DENTISTRY PR.ANKARA UNIVERSITY, FACULTY OF DENTISTRYUSKUDAR UNIVERSITY, FACULTY OF DENTISTRY Purpose: To compare the adaptation and microleakage of CAD/CAM inlay restorations using conventional or ultrasonic finishing equipment and their combinations.Materials & Methods: Inlay cavities were prepared on 66 extracted human lower first molar teeth using one of the following finishing methods: Group I: straight fissure diamond bur; Group II: fissure diamond bur and ultrasonic tip; Group III: 6º tapered conical diamond bur; Group IV: 6º tapered conical diamond bur and ultrasonic tip. Inlay restorations milled from feldspathic ceramic blocks were cemented with resin cement. Adaptation and microleakage of the restorations were evaluated by micro-CT. The adaptation of the restorations was evaluated in four areas and five determined points. The differences between the finishing methods were statistically evaluated at each measurement point.Results: The adaptation of the restorations differed between 1.07 and 330.71 µm. Statistical differences were observed in the marginal and internal adaptation of ceramic inlay restorations due to the finishing method used at some points of the ceramic and cavity interface. However, the microleakage values between the finishing methods did not show a statistical difference.Conclusion: According to the results of this study, the microleakage of the ceramic inlay restorations is not affected by the finishing method used. However, the adaptation of the restoration could be affected by the finishing method, depending on the area.Clinical Significance: Preparations for inlay restorations prepared with these special burrs and ultrasonic instruments created better marginal fit, which could result in more successful ceramic inlays.https://dergipark.org.tr/en/doi/10.52037/eads.2024.0020
spellingShingle Ayben Şentürk
Mehmet Ali Kılıçarslan
Merve Çakırbay Tanış
Mert Ocak
İbrahim Berk Bellaz
Comparison of Adaptation and Microleakage of CAD/CAM Restorations to Inlay Cavities Prepared by Using Different Finishing Methods
European Annals of Dental Sciences
title Comparison of Adaptation and Microleakage of CAD/CAM Restorations to Inlay Cavities Prepared by Using Different Finishing Methods
title_full Comparison of Adaptation and Microleakage of CAD/CAM Restorations to Inlay Cavities Prepared by Using Different Finishing Methods
title_fullStr Comparison of Adaptation and Microleakage of CAD/CAM Restorations to Inlay Cavities Prepared by Using Different Finishing Methods
title_full_unstemmed Comparison of Adaptation and Microleakage of CAD/CAM Restorations to Inlay Cavities Prepared by Using Different Finishing Methods
title_short Comparison of Adaptation and Microleakage of CAD/CAM Restorations to Inlay Cavities Prepared by Using Different Finishing Methods
title_sort comparison of adaptation and microleakage of cad cam restorations to inlay cavities prepared by using different finishing methods
url https://dergipark.org.tr/en/doi/10.52037/eads.2024.0020
work_keys_str_mv AT aybensenturk comparisonofadaptationandmicroleakageofcadcamrestorationstoinlaycavitiespreparedbyusingdifferentfinishingmethods
AT mehmetalikılıcarslan comparisonofadaptationandmicroleakageofcadcamrestorationstoinlaycavitiespreparedbyusingdifferentfinishingmethods
AT mervecakırbaytanıs comparisonofadaptationandmicroleakageofcadcamrestorationstoinlaycavitiespreparedbyusingdifferentfinishingmethods
AT mertocak comparisonofadaptationandmicroleakageofcadcamrestorationstoinlaycavitiespreparedbyusingdifferentfinishingmethods
AT ibrahimberkbellaz comparisonofadaptationandmicroleakageofcadcamrestorationstoinlaycavitiespreparedbyusingdifferentfinishingmethods