Diagnostic Value of Micropure Imaging Combined with Strain Elastography in Correcting Artificial Intelligence S-Detect Technology for Benign and Malignant Breast Complex Cystic and Solid Masses
ObjectiveTo explore the diagnostic value of micropure imaging (MI) combined with strain elastography (SE) in correcting artificial intelligence (AI) S-Detect technology for benign and malignant breast complex cystic and solid masses. MethodsThe S-Detect diagnosis results were corrected based on the...
Saved in:
| Main Authors: | , , |
|---|---|
| Format: | Article |
| Language: | zho |
| Published: |
Editorial Office of Chinese Journal of Medical Instrumentation
2024-07-01
|
| Series: | Zhongguo yiliao qixie zazhi |
| Subjects: | |
| Online Access: | https://zgylqxzz.xml-journal.net/article/doi/10.12455/j.issn.1671-7104.230710 |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
| _version_ | 1846163563400396800 |
|---|---|
| author | Jie YUAN Cheng WANG Yingfen DA |
| author_facet | Jie YUAN Cheng WANG Yingfen DA |
| author_sort | Jie YUAN |
| collection | DOAJ |
| description | ObjectiveTo explore the diagnostic value of micropure imaging (MI) combined with strain elastography (SE) in correcting artificial intelligence (AI) S-Detect technology for benign and malignant breast complex cystic and solid masses. MethodsThe S-Detect diagnosis results were corrected based on the manifestations of MI and SE of the 145 breast complex cystic and solid masses. Postoperative pathological results were used as the gold standard to calculate the diagnostic sensitivity, specificity, and accuracy before and after correction. Additionally, receiver operating characteristic (ROC) curves were drawn for both groups, and the areas under the curves were compared. ResultsThere were 80 benign and 65 malignant pathological results. After the correction of S-Detect, the diagnostic sensitivity, specificity, and accuracy, as well as the areas under the ROC curves, were all improved compared to before the correction. ConclusionCombining MI and SE to correct the diagnostic results of S-Detect can help improve the diagnostic efficacy of breast complex cystic and solid masses. |
| format | Article |
| id | doaj-art-879cfe41c8494ea39089b4801e28f347 |
| institution | Kabale University |
| issn | 1671-7104 |
| language | zho |
| publishDate | 2024-07-01 |
| publisher | Editorial Office of Chinese Journal of Medical Instrumentation |
| record_format | Article |
| series | Zhongguo yiliao qixie zazhi |
| spelling | doaj-art-879cfe41c8494ea39089b4801e28f3472024-11-19T06:09:14ZzhoEditorial Office of Chinese Journal of Medical InstrumentationZhongguo yiliao qixie zazhi1671-71042024-07-0148442642910.12455/j.issn.1671-7104.2307102023-0710Diagnostic Value of Micropure Imaging Combined with Strain Elastography in Correcting Artificial Intelligence S-Detect Technology for Benign and Malignant Breast Complex Cystic and Solid MassesJie YUAN0Cheng WANG1Yingfen DA2Department of Ultrasound, Huangpu Branch of Shanghai Ninth People's Hospital Affiliated to Shanghai Jiao Tong University School of Medicine, Shanghai, 200011Department of Breast Surgery, Huangpu Branch of Shanghai Ninth People's Hospital Affiliated to Shanghai Jiao Tong University School of Medicine, Shanghai, 200011Department of Ultrasound, Huangpu Branch of Shanghai Ninth People's Hospital Affiliated to Shanghai Jiao Tong University School of Medicine, Shanghai, 200011ObjectiveTo explore the diagnostic value of micropure imaging (MI) combined with strain elastography (SE) in correcting artificial intelligence (AI) S-Detect technology for benign and malignant breast complex cystic and solid masses. MethodsThe S-Detect diagnosis results were corrected based on the manifestations of MI and SE of the 145 breast complex cystic and solid masses. Postoperative pathological results were used as the gold standard to calculate the diagnostic sensitivity, specificity, and accuracy before and after correction. Additionally, receiver operating characteristic (ROC) curves were drawn for both groups, and the areas under the curves were compared. ResultsThere were 80 benign and 65 malignant pathological results. After the correction of S-Detect, the diagnostic sensitivity, specificity, and accuracy, as well as the areas under the ROC curves, were all improved compared to before the correction. ConclusionCombining MI and SE to correct the diagnostic results of S-Detect can help improve the diagnostic efficacy of breast complex cystic and solid masses.https://zgylqxzz.xml-journal.net/article/doi/10.12455/j.issn.1671-7104.230710ultrasonographybreast complex cystic and solid massesartificial intelligences-detect technologymicropure imagingstrain elastography |
| spellingShingle | Jie YUAN Cheng WANG Yingfen DA Diagnostic Value of Micropure Imaging Combined with Strain Elastography in Correcting Artificial Intelligence S-Detect Technology for Benign and Malignant Breast Complex Cystic and Solid Masses Zhongguo yiliao qixie zazhi ultrasonography breast complex cystic and solid masses artificial intelligence s-detect technology micropure imaging strain elastography |
| title | Diagnostic Value of Micropure Imaging Combined with Strain Elastography in Correcting Artificial Intelligence S-Detect Technology for Benign and Malignant Breast Complex Cystic and Solid Masses |
| title_full | Diagnostic Value of Micropure Imaging Combined with Strain Elastography in Correcting Artificial Intelligence S-Detect Technology for Benign and Malignant Breast Complex Cystic and Solid Masses |
| title_fullStr | Diagnostic Value of Micropure Imaging Combined with Strain Elastography in Correcting Artificial Intelligence S-Detect Technology for Benign and Malignant Breast Complex Cystic and Solid Masses |
| title_full_unstemmed | Diagnostic Value of Micropure Imaging Combined with Strain Elastography in Correcting Artificial Intelligence S-Detect Technology for Benign and Malignant Breast Complex Cystic and Solid Masses |
| title_short | Diagnostic Value of Micropure Imaging Combined with Strain Elastography in Correcting Artificial Intelligence S-Detect Technology for Benign and Malignant Breast Complex Cystic and Solid Masses |
| title_sort | diagnostic value of micropure imaging combined with strain elastography in correcting artificial intelligence s detect technology for benign and malignant breast complex cystic and solid masses |
| topic | ultrasonography breast complex cystic and solid masses artificial intelligence s-detect technology micropure imaging strain elastography |
| url | https://zgylqxzz.xml-journal.net/article/doi/10.12455/j.issn.1671-7104.230710 |
| work_keys_str_mv | AT jieyuan diagnosticvalueofmicropureimagingcombinedwithstrainelastographyincorrectingartificialintelligencesdetecttechnologyforbenignandmalignantbreastcomplexcysticandsolidmasses AT chengwang diagnosticvalueofmicropureimagingcombinedwithstrainelastographyincorrectingartificialintelligencesdetecttechnologyforbenignandmalignantbreastcomplexcysticandsolidmasses AT yingfenda diagnosticvalueofmicropureimagingcombinedwithstrainelastographyincorrectingartificialintelligencesdetecttechnologyforbenignandmalignantbreastcomplexcysticandsolidmasses |