Strain energy density criterion as failure assessment for quasi-static uni-axial tensile load

Strain energy density is successfully used as criterion for failure assessment of brittle and quasi-brittle material behavior. This work investigates the possibility to use this method to predict the strength of V-notched specimens made of PMMA under static uniaxial tensile load. Samples are charact...

Full description

Saved in:
Bibliographic Details
Main Authors: Andrea Kusch, Simone Salamina, Daniele Crivelli, Filippo Berto
Format: Article
Language:English
Published: Gruppo Italiano Frattura 2021-07-01
Series:Fracture and Structural Integrity
Subjects:
Online Access:https://www.fracturae.com/index.php/fis/article/view/3104/3285
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1846092584936538112
author Andrea Kusch
Simone Salamina
Daniele Crivelli
Filippo Berto
author_facet Andrea Kusch
Simone Salamina
Daniele Crivelli
Filippo Berto
author_sort Andrea Kusch
collection DOAJ
description Strain energy density is successfully used as criterion for failure assessment of brittle and quasi-brittle material behavior. This work investigates the possibility to use this method to predict the strength of V-notched specimens made of PMMA under static uniaxial tensile load. Samples are characterized by a variability of notch root radii and notch opening angles. Notched specimens fail with a quasi-brittle behavior, albeit PMMA has a nonlinear stress strain curve at room temperature. The notch root radius has most influence on the strength of the specimen, whereas the angle is less relevant. The value of the strain energy density is computed by means of finite element analysis, the material is considered as linear elastic. Failure predictions, based on the critical value of the strain energy density in a well-defined volume surrounding the notch tip, show very good agreement (error minus 15%) with experimental data.
format Article
id doaj-art-86291eedf3484e1d8b342b79d04f29a1
institution Kabale University
issn 1971-8993
language English
publishDate 2021-07-01
publisher Gruppo Italiano Frattura
record_format Article
series Fracture and Structural Integrity
spelling doaj-art-86291eedf3484e1d8b342b79d04f29a12025-01-02T20:54:58ZengGruppo Italiano FratturaFracture and Structural Integrity1971-89932021-07-01155733134910.3221/IGF-ESIS.57.2410.3221/IGF-ESIS.57.24Strain energy density criterion as failure assessment for quasi-static uni-axial tensile loadAndrea KuschSimone SalaminaDaniele CrivelliFilippo BertoStrain energy density is successfully used as criterion for failure assessment of brittle and quasi-brittle material behavior. This work investigates the possibility to use this method to predict the strength of V-notched specimens made of PMMA under static uniaxial tensile load. Samples are characterized by a variability of notch root radii and notch opening angles. Notched specimens fail with a quasi-brittle behavior, albeit PMMA has a nonlinear stress strain curve at room temperature. The notch root radius has most influence on the strength of the specimen, whereas the angle is less relevant. The value of the strain energy density is computed by means of finite element analysis, the material is considered as linear elastic. Failure predictions, based on the critical value of the strain energy density in a well-defined volume surrounding the notch tip, show very good agreement (error minus 15%) with experimental data.https://www.fracturae.com/index.php/fis/article/view/3104/3285strain energy densityquasi-brittle materialpmmafailure assessment.
spellingShingle Andrea Kusch
Simone Salamina
Daniele Crivelli
Filippo Berto
Strain energy density criterion as failure assessment for quasi-static uni-axial tensile load
Fracture and Structural Integrity
strain energy density
quasi-brittle material
pmma
failure assessment.
title Strain energy density criterion as failure assessment for quasi-static uni-axial tensile load
title_full Strain energy density criterion as failure assessment for quasi-static uni-axial tensile load
title_fullStr Strain energy density criterion as failure assessment for quasi-static uni-axial tensile load
title_full_unstemmed Strain energy density criterion as failure assessment for quasi-static uni-axial tensile load
title_short Strain energy density criterion as failure assessment for quasi-static uni-axial tensile load
title_sort strain energy density criterion as failure assessment for quasi static uni axial tensile load
topic strain energy density
quasi-brittle material
pmma
failure assessment.
url https://www.fracturae.com/index.php/fis/article/view/3104/3285
work_keys_str_mv AT andreakusch strainenergydensitycriterionasfailureassessmentforquasistaticuniaxialtensileload
AT simonesalamina strainenergydensitycriterionasfailureassessmentforquasistaticuniaxialtensileload
AT danielecrivelli strainenergydensitycriterionasfailureassessmentforquasistaticuniaxialtensileload
AT filippoberto strainenergydensitycriterionasfailureassessmentforquasistaticuniaxialtensileload