Results of eye lens doses control of medical personnel in St. Petersburg

Results of individual monitoring for personnel of X-ray surgical teams in several clinics of St. Petersburg are presented and analyzed. Measurements of the operational quantities – individual dose equivalents Hp (3) and Hp (10) were performed by thermoluminescent dosimetry method. Dosimeters designe...

Full description

Saved in:
Bibliographic Details
Main Authors: Ekaterina N. Shleenkova, Vladislav Yu. Golikov, Georgy N. Kaidanovsky, Stepan Yu. Bazhin, Vladimir A. Ilyin
Format: Article
Language:English
Published: Saint-Petersburg Research Institute of Radiation Hygiene after Professor P.V. Ramzaev 2020-01-01
Series:Радиационная гигиена
Subjects:
Online Access:https://www.radhyg.ru/jour/article/view/655
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849240308548632576
author Ekaterina N. Shleenkova
Vladislav Yu. Golikov
Georgy N. Kaidanovsky
Stepan Yu. Bazhin
Vladimir A. Ilyin
author_facet Ekaterina N. Shleenkova
Vladislav Yu. Golikov
Georgy N. Kaidanovsky
Stepan Yu. Bazhin
Vladimir A. Ilyin
author_sort Ekaterina N. Shleenkova
collection DOAJ
description Results of individual monitoring for personnel of X-ray surgical teams in several clinics of St. Petersburg are presented and analyzed. Measurements of the operational quantities – individual dose equivalents Hp (3) and Hp (10) were performed by thermoluminescent dosimetry method. Dosimeters designed to measure Hp (3) were located in the operators forehead area, and to determine Hp (10) both above the operator ‘s individual protective apron in the collar or chest area and under the protective apron in the chest area. The results of 34 measurements of the annual values of Hp (3) and Hp (10) measured above the apron and 24 values of Hp (10) measured below the apron were processed and analyzed. The results after the statistical treatment show that the probability of exceeding the annual values of Hp (3) in the personnel of X-ray surgical teams of the new dose limit 20 mSv is small, less than 1%. Exceeding the current dose limit of the equivalent exposure dose of the lens of the eye (150 mSv) is hardly possible at all under normal conditions. The best solution for evaluating the radiation dose of the lens of the eye is to measure the individual equivalent of the dose Hp (3), using a suitably calibrated TL-dosimeter (thermoluminescent dosimeter) located near the worker’s eyes. However, this additional dosimeter is only necessary when the values of eye lens equivalent dose can approach the new value of dose limit of 20 mSv. According to the results of the study, it is possible to introduce such an additional dosimeter if the annual value of Hp (10) recorded by the dosimeter located above the protective apron is more than 10 mSv.
format Article
id doaj-art-85250d3ba0584c9fa68cace52d3b8e3e
institution Kabale University
issn 1998-426X
language English
publishDate 2020-01-01
publisher Saint-Petersburg Research Institute of Radiation Hygiene after Professor P.V. Ramzaev
record_format Article
series Радиационная гигиена
spelling doaj-art-85250d3ba0584c9fa68cace52d3b8e3e2025-08-20T04:00:39ZengSaint-Petersburg Research Institute of Radiation Hygiene after Professor P.V. RamzaevРадиационная гигиена1998-426X2020-01-01124293610.21514/1998-426X-2019-12-4-29-36617Results of eye lens doses control of medical personnel in St. PetersburgEkaterina N. Shleenkova0Vladislav Yu. Golikov1Georgy N. Kaidanovsky2Stepan Yu. Bazhin3Vladimir A. Ilyin4Saint-Petersburg Research Institute of Radiation Hygiene after Professor P.V. Ramzaev, Federal Service for Surveillance on Consumer Rights Protection and Human Well-BeingSaint-Petersburg Research Institute of Radiation Hygiene after Professor P.V. Ramzaev, Federal Service for Surveillance on Consumer Rights Protection and Human Well-BeingSaint-Petersburg Research Institute of Radiation Hygiene after Professor P.V. Ramzaev, Federal Service for Surveillance on Consumer Rights Protection and Human Well-BeingSaint-Petersburg Research Institute of Radiation Hygiene after Professor P.V. Ramzaev, Federal Service for Surveillance on Consumer Rights Protection and Human Well-BeingSaint-Petersburg Research Institute of Radiation Hygiene after Professor P.V. Ramzaev, Federal Service for Surveillance on Consumer Rights Protection and Human Well-BeingResults of individual monitoring for personnel of X-ray surgical teams in several clinics of St. Petersburg are presented and analyzed. Measurements of the operational quantities – individual dose equivalents Hp (3) and Hp (10) were performed by thermoluminescent dosimetry method. Dosimeters designed to measure Hp (3) were located in the operators forehead area, and to determine Hp (10) both above the operator ‘s individual protective apron in the collar or chest area and under the protective apron in the chest area. The results of 34 measurements of the annual values of Hp (3) and Hp (10) measured above the apron and 24 values of Hp (10) measured below the apron were processed and analyzed. The results after the statistical treatment show that the probability of exceeding the annual values of Hp (3) in the personnel of X-ray surgical teams of the new dose limit 20 mSv is small, less than 1%. Exceeding the current dose limit of the equivalent exposure dose of the lens of the eye (150 mSv) is hardly possible at all under normal conditions. The best solution for evaluating the radiation dose of the lens of the eye is to measure the individual equivalent of the dose Hp (3), using a suitably calibrated TL-dosimeter (thermoluminescent dosimeter) located near the worker’s eyes. However, this additional dosimeter is only necessary when the values of eye lens equivalent dose can approach the new value of dose limit of 20 mSv. According to the results of the study, it is possible to introduce such an additional dosimeter if the annual value of Hp (10) recorded by the dosimeter located above the protective apron is more than 10 mSv.https://www.radhyg.ru/jour/article/view/655individual dose monitoringeye lens equivalent doseindividual dose equivalent
spellingShingle Ekaterina N. Shleenkova
Vladislav Yu. Golikov
Georgy N. Kaidanovsky
Stepan Yu. Bazhin
Vladimir A. Ilyin
Results of eye lens doses control of medical personnel in St. Petersburg
Радиационная гигиена
individual dose monitoring
eye lens equivalent dose
individual dose equivalent
title Results of eye lens doses control of medical personnel in St. Petersburg
title_full Results of eye lens doses control of medical personnel in St. Petersburg
title_fullStr Results of eye lens doses control of medical personnel in St. Petersburg
title_full_unstemmed Results of eye lens doses control of medical personnel in St. Petersburg
title_short Results of eye lens doses control of medical personnel in St. Petersburg
title_sort results of eye lens doses control of medical personnel in st petersburg
topic individual dose monitoring
eye lens equivalent dose
individual dose equivalent
url https://www.radhyg.ru/jour/article/view/655
work_keys_str_mv AT ekaterinanshleenkova resultsofeyelensdosescontrolofmedicalpersonnelinstpetersburg
AT vladislavyugolikov resultsofeyelensdosescontrolofmedicalpersonnelinstpetersburg
AT georgynkaidanovsky resultsofeyelensdosescontrolofmedicalpersonnelinstpetersburg
AT stepanyubazhin resultsofeyelensdosescontrolofmedicalpersonnelinstpetersburg
AT vladimirailyin resultsofeyelensdosescontrolofmedicalpersonnelinstpetersburg