DSTATCOM-BASED 15 LEVEL ASYMMETRICAL MULTILEVEL INVERTER FOR IMPROVING POWER QUALITY

This study suggests an asymmetric multilevel inverter based on DSTATCOM that employs SVPWM techniques to produce higher output levels. There are two steps in the suggested inverter. One full bridge and two half bridges make up the inverter's main stage. A full bridge converter had four switche...

Full description

Saved in:
Bibliographic Details
Main Authors: Panneerselvam Sundaramoorthi, Govindasamy Saravana Venkatesh
Format: Article
Language:English
Published: Lublin University of Technology 2024-12-01
Series:Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska
Subjects:
Online Access:https://ph.pollub.pl/index.php/iapgos/article/view/6355
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1846113006821310464
author Panneerselvam Sundaramoorthi
Govindasamy Saravana Venkatesh
author_facet Panneerselvam Sundaramoorthi
Govindasamy Saravana Venkatesh
author_sort Panneerselvam Sundaramoorthi
collection DOAJ
description This study suggests an asymmetric multilevel inverter based on DSTATCOM that employs SVPWM techniques to produce higher output levels. There are two steps in the suggested inverter. One full bridge and two half bridges make up the inverter's main stage. A full bridge converter had four switches and a single DC source, while half bridges have separate DC sources with a voltage ratio of 1:3:3. Every cell has a fixed neutral point and is connected in a cascaded fashion. The inverter's performance is not improved by setting the DC source values equally. A folded cascaded H-bridge circuit running at a line frequency makes up the second circuit. Control plan PWM's space vector modulation was used to verify the suggested topology. Each control scheme's specific methodology as well as switching pulses are covered in great detail. In MATLAB/Simulink, the suggested system has been simulated with an output voltage of 350 V and an output current of roughly 3.5 A.
format Article
id doaj-art-85149c46d9fc42aeadcab377d5e54adb
institution Kabale University
issn 2083-0157
2391-6761
language English
publishDate 2024-12-01
publisher Lublin University of Technology
record_format Article
series Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska
spelling doaj-art-85149c46d9fc42aeadcab377d5e54adb2024-12-22T09:02:19ZengLublin University of TechnologyInformatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska2083-01572391-67612024-12-0114410.35784/iapgos.6355DSTATCOM-BASED 15 LEVEL ASYMMETRICAL MULTILEVEL INVERTER FOR IMPROVING POWER QUALITYPanneerselvam Sundaramoorthi0https://orcid.org/0000-0002-9321-140XGovindasamy Saravana Venkatesh1https://orcid.org/0000-0002-0154-2974Periyar Maniammai Institute of Science and Technology, Research ScholarPeriyar Maniammai Institute of Science and Technology, Department of Electrical and Electronics Engineering This study suggests an asymmetric multilevel inverter based on DSTATCOM that employs SVPWM techniques to produce higher output levels. There are two steps in the suggested inverter. One full bridge and two half bridges make up the inverter's main stage. A full bridge converter had four switches and a single DC source, while half bridges have separate DC sources with a voltage ratio of 1:3:3. Every cell has a fixed neutral point and is connected in a cascaded fashion. The inverter's performance is not improved by setting the DC source values equally. A folded cascaded H-bridge circuit running at a line frequency makes up the second circuit. Control plan PWM's space vector modulation was used to verify the suggested topology. Each control scheme's specific methodology as well as switching pulses are covered in great detail. In MATLAB/Simulink, the suggested system has been simulated with an output voltage of 350 V and an output current of roughly 3.5 A. https://ph.pollub.pl/index.php/iapgos/article/view/6355DSTATCOMTHD reductionPWM schememulticarrier PWM schemeSVPWM scheme
spellingShingle Panneerselvam Sundaramoorthi
Govindasamy Saravana Venkatesh
DSTATCOM-BASED 15 LEVEL ASYMMETRICAL MULTILEVEL INVERTER FOR IMPROVING POWER QUALITY
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska
DSTATCOM
THD reduction
PWM scheme
multicarrier PWM scheme
SVPWM scheme
title DSTATCOM-BASED 15 LEVEL ASYMMETRICAL MULTILEVEL INVERTER FOR IMPROVING POWER QUALITY
title_full DSTATCOM-BASED 15 LEVEL ASYMMETRICAL MULTILEVEL INVERTER FOR IMPROVING POWER QUALITY
title_fullStr DSTATCOM-BASED 15 LEVEL ASYMMETRICAL MULTILEVEL INVERTER FOR IMPROVING POWER QUALITY
title_full_unstemmed DSTATCOM-BASED 15 LEVEL ASYMMETRICAL MULTILEVEL INVERTER FOR IMPROVING POWER QUALITY
title_short DSTATCOM-BASED 15 LEVEL ASYMMETRICAL MULTILEVEL INVERTER FOR IMPROVING POWER QUALITY
title_sort dstatcom based 15 level asymmetrical multilevel inverter for improving power quality
topic DSTATCOM
THD reduction
PWM scheme
multicarrier PWM scheme
SVPWM scheme
url https://ph.pollub.pl/index.php/iapgos/article/view/6355
work_keys_str_mv AT panneerselvamsundaramoorthi dstatcombased15levelasymmetricalmultilevelinverterforimprovingpowerquality
AT govindasamysaravanavenkatesh dstatcombased15levelasymmetricalmultilevelinverterforimprovingpowerquality