Operation monitoring platform of relay protection equipment at distribution network side under the background of new power system

Abstract The new power system puts forward higher requirements for the functionality, real-time performance and reliability of relay protection equipment. Therefore, this paper designs a monitoring platform for the operation of relay protection equipment at distribution network side under the backgr...

Full description

Saved in:
Bibliographic Details
Main Authors: Qingsheng Li, Yu Zhang, Zhaofeng Zhang, Zhen Li
Format: Article
Language:English
Published: SpringerOpen 2024-12-01
Series:Energy Informatics
Subjects:
Online Access:https://doi.org/10.1186/s42162-024-00440-1
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1841559076284137472
author Qingsheng Li
Yu Zhang
Zhaofeng Zhang
Zhen Li
author_facet Qingsheng Li
Yu Zhang
Zhaofeng Zhang
Zhen Li
author_sort Qingsheng Li
collection DOAJ
description Abstract The new power system puts forward higher requirements for the functionality, real-time performance and reliability of relay protection equipment. Therefore, this paper designs a monitoring platform for the operation of relay protection equipment at distribution network side under the background of new power system. The platform obtains the running state of relay protection equipment by establishing simulation models of different types of relay protection equipment on the distribution network side. The fault time, fault type and current action of relay protection equipment at distribution network side are analyzed to realize the monitoring of operation state. At the same time, the visual representation method of monitoring data based on three-dimensional parallel scattergram and human-computer interaction is adopted for human-computer interaction, and the electromechanical protection device is controlled to realize current quick-break protection and overcurrent protection. The experimental results show that the platform can effectively monitor the operation of relay protection equipment on the distribution network side in real time and accurately judge the action of the equipment, and the application effect is good.
format Article
id doaj-art-840e2fc47a5946f2b2a032dc9e8f8ea4
institution Kabale University
issn 2520-8942
language English
publishDate 2024-12-01
publisher SpringerOpen
record_format Article
series Energy Informatics
spelling doaj-art-840e2fc47a5946f2b2a032dc9e8f8ea42025-01-05T12:48:07ZengSpringerOpenEnergy Informatics2520-89422024-12-017112410.1186/s42162-024-00440-1Operation monitoring platform of relay protection equipment at distribution network side under the background of new power systemQingsheng Li0Yu Zhang1Zhaofeng Zhang2Zhen Li3Power Grid Planning Research Center of Guizhou Power GridPower Grid Planning Research Center of Guizhou Power GridPower Grid Planning Research Center of Guizhou Power GridPower Grid Planning Research Center of Guizhou Power GridAbstract The new power system puts forward higher requirements for the functionality, real-time performance and reliability of relay protection equipment. Therefore, this paper designs a monitoring platform for the operation of relay protection equipment at distribution network side under the background of new power system. The platform obtains the running state of relay protection equipment by establishing simulation models of different types of relay protection equipment on the distribution network side. The fault time, fault type and current action of relay protection equipment at distribution network side are analyzed to realize the monitoring of operation state. At the same time, the visual representation method of monitoring data based on three-dimensional parallel scattergram and human-computer interaction is adopted for human-computer interaction, and the electromechanical protection device is controlled to realize current quick-break protection and overcurrent protection. The experimental results show that the platform can effectively monitor the operation of relay protection equipment on the distribution network side in real time and accurately judge the action of the equipment, and the application effect is good.https://doi.org/10.1186/s42162-024-00440-1New power systemDistribution network sideRelay protection equipmentOperation monitoringRunning stateVisualization
spellingShingle Qingsheng Li
Yu Zhang
Zhaofeng Zhang
Zhen Li
Operation monitoring platform of relay protection equipment at distribution network side under the background of new power system
Energy Informatics
New power system
Distribution network side
Relay protection equipment
Operation monitoring
Running state
Visualization
title Operation monitoring platform of relay protection equipment at distribution network side under the background of new power system
title_full Operation monitoring platform of relay protection equipment at distribution network side under the background of new power system
title_fullStr Operation monitoring platform of relay protection equipment at distribution network side under the background of new power system
title_full_unstemmed Operation monitoring platform of relay protection equipment at distribution network side under the background of new power system
title_short Operation monitoring platform of relay protection equipment at distribution network side under the background of new power system
title_sort operation monitoring platform of relay protection equipment at distribution network side under the background of new power system
topic New power system
Distribution network side
Relay protection equipment
Operation monitoring
Running state
Visualization
url https://doi.org/10.1186/s42162-024-00440-1
work_keys_str_mv AT qingshengli operationmonitoringplatformofrelayprotectionequipmentatdistributionnetworksideunderthebackgroundofnewpowersystem
AT yuzhang operationmonitoringplatformofrelayprotectionequipmentatdistributionnetworksideunderthebackgroundofnewpowersystem
AT zhaofengzhang operationmonitoringplatformofrelayprotectionequipmentatdistributionnetworksideunderthebackgroundofnewpowersystem
AT zhenli operationmonitoringplatformofrelayprotectionequipmentatdistributionnetworksideunderthebackgroundofnewpowersystem