Comparison of 3D-navigation and fluoroscopic guidance in percutaneous pedicle screw placement for traumatic fractures of the thoracolumbar junction
Introduction: Fractures of the thoracolumbar junction are the most common vertebral fractures and can require surgical treatment. Several studies have shown that the accuracy of pedicle screw placement can be improved by the use of 3D-navigation. Still only few studies have focused on the use of nav...
Saved in:
Main Authors: | , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Elsevier
2024-01-01
|
Series: | Brain and Spine |
Subjects: | |
Online Access: | http://www.sciencedirect.com/science/article/pii/S2772529424000250 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
_version_ | 1846121988628676608 |
---|---|
author | Fenna Brunken Eric Mandelka Benno Bullert Paul Alfred Gruetzner Sven Y. Vetter Jula Gierse |
author_facet | Fenna Brunken Eric Mandelka Benno Bullert Paul Alfred Gruetzner Sven Y. Vetter Jula Gierse |
author_sort | Fenna Brunken |
collection | DOAJ |
description | Introduction: Fractures of the thoracolumbar junction are the most common vertebral fractures and can require surgical treatment. Several studies have shown that the accuracy of pedicle screw placement can be improved by the use of 3D-navigation. Still only few studies have focused on the use of navigation in traumatic spine injuries. Research question: The aim of this study was to compare the screw placement accuracy and radiation exposure for 3D-navigated and fluoroscopy-guided percutaneous pedicle screw placement in traumatic fractures of the thoracolumbar junction. Materials and methods: In this single-center study 25 patients undergoing 3D-navigated percutaneous pedicle screw placement for traumatic fractures of the thoracolumbar junction (T12-L2) were compared to a control group of 25 patients using fluoroscopy. Screw accuracy was determined in postoperative CT-scans using the Gertzbein-Robbins classification system. Additionally, duration of surgery, dose area product, fluoroscopy time and intraoperative complications were compared between the groups. Results: The accuracy of 3D-navigated percutaneous pedicle screw placement was 92.66 % while an accuracy of 88.08 % was achieved using standard fluoroscopy (p = 0.19). The fluoroscopy time was significantly less in the navigation group compared to the control group (p = 0.0002). There were no significant differences in radiation exposure, duration of surgery or intraoperative complications between the groups. Discussion and conclusion: The results suggest that 3D-navigation facilitates higher accuracy in percutaneous pedicle screw placement of traumatic fractures of the thoracolumbar junction, although limitations should be considered. In this study 3D-navigation did not increase fluoroscopy time, while radiation exposure and surgery time were comparable. |
format | Article |
id | doaj-art-82917a0b15c74b7e946c1543c67c06ad |
institution | Kabale University |
issn | 2772-5294 |
language | English |
publishDate | 2024-01-01 |
publisher | Elsevier |
record_format | Article |
series | Brain and Spine |
spelling | doaj-art-82917a0b15c74b7e946c1543c67c06ad2024-12-15T06:18:13ZengElsevierBrain and Spine2772-52942024-01-014102769Comparison of 3D-navigation and fluoroscopic guidance in percutaneous pedicle screw placement for traumatic fractures of the thoracolumbar junctionFenna Brunken0Eric Mandelka1Benno Bullert2Paul Alfred Gruetzner3Sven Y. Vetter4Jula Gierse5Research Group Medical Imaging and Navigation in Trauma and Orthopedic Surgery (MINTOS), Department of Orthopedics and Trauma Surgery, BG Klinik Ludwigshafen, Ludwig-Guttmann-Str. 13, 67071, Ludwigshafen, Germany; Heidelberg University, Grabengasse 1, 69117 Heidelberg, GermanyResearch Group Medical Imaging and Navigation in Trauma and Orthopedic Surgery (MINTOS), Department of Orthopedics and Trauma Surgery, BG Klinik Ludwigshafen, Ludwig-Guttmann-Str. 13, 67071, Ludwigshafen, Germany; Heidelberg University, Grabengasse 1, 69117 Heidelberg, GermanyResearch Group Medical Imaging and Navigation in Trauma and Orthopedic Surgery (MINTOS), Department of Orthopedics and Trauma Surgery, BG Klinik Ludwigshafen, Ludwig-Guttmann-Str. 13, 67071, Ludwigshafen, Germany; Heidelberg University, Grabengasse 1, 69117 Heidelberg, GermanyResearch Group Medical Imaging and Navigation in Trauma and Orthopedic Surgery (MINTOS), Department of Orthopedics and Trauma Surgery, BG Klinik Ludwigshafen, Ludwig-Guttmann-Str. 13, 67071, Ludwigshafen, Germany; Heidelberg University, Grabengasse 1, 69117 Heidelberg, GermanyResearch Group Medical Imaging and Navigation in Trauma and Orthopedic Surgery (MINTOS), Department of Orthopedics and Trauma Surgery, BG Klinik Ludwigshafen, Ludwig-Guttmann-Str. 13, 67071, Ludwigshafen, Germany; Heidelberg University, Grabengasse 1, 69117 Heidelberg, GermanyResearch Group Medical Imaging and Navigation in Trauma and Orthopedic Surgery (MINTOS), Department of Orthopedics and Trauma Surgery, BG Klinik Ludwigshafen, Ludwig-Guttmann-Str. 13, 67071, Ludwigshafen, Germany; Heidelberg University, Grabengasse 1, 69117 Heidelberg, Germany; Corresponding author. Research Group Medical Imaging and Navigation in Trauma and Orthopedic Surgery (MINTOS), Department of Orthopedics and Trauma Surgery, BG Klinik Ludwigshafen, Ludwig-Guttmann-Str. 13, 67071, Ludwigshafen, Germany.Introduction: Fractures of the thoracolumbar junction are the most common vertebral fractures and can require surgical treatment. Several studies have shown that the accuracy of pedicle screw placement can be improved by the use of 3D-navigation. Still only few studies have focused on the use of navigation in traumatic spine injuries. Research question: The aim of this study was to compare the screw placement accuracy and radiation exposure for 3D-navigated and fluoroscopy-guided percutaneous pedicle screw placement in traumatic fractures of the thoracolumbar junction. Materials and methods: In this single-center study 25 patients undergoing 3D-navigated percutaneous pedicle screw placement for traumatic fractures of the thoracolumbar junction (T12-L2) were compared to a control group of 25 patients using fluoroscopy. Screw accuracy was determined in postoperative CT-scans using the Gertzbein-Robbins classification system. Additionally, duration of surgery, dose area product, fluoroscopy time and intraoperative complications were compared between the groups. Results: The accuracy of 3D-navigated percutaneous pedicle screw placement was 92.66 % while an accuracy of 88.08 % was achieved using standard fluoroscopy (p = 0.19). The fluoroscopy time was significantly less in the navigation group compared to the control group (p = 0.0002). There were no significant differences in radiation exposure, duration of surgery or intraoperative complications between the groups. Discussion and conclusion: The results suggest that 3D-navigation facilitates higher accuracy in percutaneous pedicle screw placement of traumatic fractures of the thoracolumbar junction, although limitations should be considered. In this study 3D-navigation did not increase fluoroscopy time, while radiation exposure and surgery time were comparable.http://www.sciencedirect.com/science/article/pii/S2772529424000250Spinal navigationIntraoperative 3D-imagingPedicle screw accuracyPercutaneous pedicle screw placement |
spellingShingle | Fenna Brunken Eric Mandelka Benno Bullert Paul Alfred Gruetzner Sven Y. Vetter Jula Gierse Comparison of 3D-navigation and fluoroscopic guidance in percutaneous pedicle screw placement for traumatic fractures of the thoracolumbar junction Brain and Spine Spinal navigation Intraoperative 3D-imaging Pedicle screw accuracy Percutaneous pedicle screw placement |
title | Comparison of 3D-navigation and fluoroscopic guidance in percutaneous pedicle screw placement for traumatic fractures of the thoracolumbar junction |
title_full | Comparison of 3D-navigation and fluoroscopic guidance in percutaneous pedicle screw placement for traumatic fractures of the thoracolumbar junction |
title_fullStr | Comparison of 3D-navigation and fluoroscopic guidance in percutaneous pedicle screw placement for traumatic fractures of the thoracolumbar junction |
title_full_unstemmed | Comparison of 3D-navigation and fluoroscopic guidance in percutaneous pedicle screw placement for traumatic fractures of the thoracolumbar junction |
title_short | Comparison of 3D-navigation and fluoroscopic guidance in percutaneous pedicle screw placement for traumatic fractures of the thoracolumbar junction |
title_sort | comparison of 3d navigation and fluoroscopic guidance in percutaneous pedicle screw placement for traumatic fractures of the thoracolumbar junction |
topic | Spinal navigation Intraoperative 3D-imaging Pedicle screw accuracy Percutaneous pedicle screw placement |
url | http://www.sciencedirect.com/science/article/pii/S2772529424000250 |
work_keys_str_mv | AT fennabrunken comparisonof3dnavigationandfluoroscopicguidanceinpercutaneouspediclescrewplacementfortraumaticfracturesofthethoracolumbarjunction AT ericmandelka comparisonof3dnavigationandfluoroscopicguidanceinpercutaneouspediclescrewplacementfortraumaticfracturesofthethoracolumbarjunction AT bennobullert comparisonof3dnavigationandfluoroscopicguidanceinpercutaneouspediclescrewplacementfortraumaticfracturesofthethoracolumbarjunction AT paulalfredgruetzner comparisonof3dnavigationandfluoroscopicguidanceinpercutaneouspediclescrewplacementfortraumaticfracturesofthethoracolumbarjunction AT svenyvetter comparisonof3dnavigationandfluoroscopicguidanceinpercutaneouspediclescrewplacementfortraumaticfracturesofthethoracolumbarjunction AT julagierse comparisonof3dnavigationandfluoroscopicguidanceinpercutaneouspediclescrewplacementfortraumaticfracturesofthethoracolumbarjunction |