High-Sensitivity Flow Cytometry for the Reliable Detection of Measurable Residual Disease in Hematological Malignancies in Clinical Laboratories

Background: Monitoring of measurable residual disease (MRD) requires highly sensitive flow cytometry protocols to provide an accurate prediction of shorter progression-free survival. High assay sensitivity generally requires rapid processing to avoid cell loss from small bone marrow sample volumes,...

Full description

Saved in:
Bibliographic Details
Main Authors: María Beatriz Álvarez Flores, María Sopeña Corvinos, Raquel Guillén Santos, Fernando Cava Valenciano
Format: Article
Language:English
Published: MDPI AG 2024-12-01
Series:Diseases
Subjects:
Online Access:https://www.mdpi.com/2079-9721/12/12/338
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1846105001636659200
author María Beatriz Álvarez Flores
María Sopeña Corvinos
Raquel Guillén Santos
Fernando Cava Valenciano
author_facet María Beatriz Álvarez Flores
María Sopeña Corvinos
Raquel Guillén Santos
Fernando Cava Valenciano
author_sort María Beatriz Álvarez Flores
collection DOAJ
description Background: Monitoring of measurable residual disease (MRD) requires highly sensitive flow cytometry protocols to provide an accurate prediction of shorter progression-free survival. High assay sensitivity generally requires rapid processing to avoid cell loss from small bone marrow sample volumes, but this requirement conflicts with the need in most clinical cytometry laboratories for long processing and acquisition times, especially when multiple MRD studies coincide on the same day. Methods: The proposed protocol was applied to 226 human bone marrow and 45 peripheral blood samples submitted for the study of MRD or the detection of rare cells. Samples were processed within 24 h of extraction and acquired with an eight-color flow cytometer. Results: The FACSLyse-Bulk protocol allows for the labelling of millions of cells in under 90 min in small sample volumes without affecting the FSC/SSC pattern or antigen expression, and it also allows antigens to be fixed to the membrane, thus avoiding the capping phenomenon. Conclusions: The proposed protocol would allow clinical flow cytometry laboratories to perform MRD studies in house and easily achieve a limit of detection and limit of quantification <0.001%, thus avoiding the need to outsource analysis to specialized cytometry laboratories.
format Article
id doaj-art-8027f0fb1f9b4f5b87fd3d7be07d1f53
institution Kabale University
issn 2079-9721
language English
publishDate 2024-12-01
publisher MDPI AG
record_format Article
series Diseases
spelling doaj-art-8027f0fb1f9b4f5b87fd3d7be07d1f532024-12-27T14:21:24ZengMDPI AGDiseases2079-97212024-12-01121233810.3390/diseases12120338High-Sensitivity Flow Cytometry for the Reliable Detection of Measurable Residual Disease in Hematological Malignancies in Clinical LaboratoriesMaría Beatriz Álvarez Flores0María Sopeña Corvinos1Raquel Guillén Santos2Fernando Cava Valenciano3Centro Nacional de Investigaciones Cardiovasculares Carlos III, 28029 Madrid, SpainURSalud Laboratory, Hospital Universitario Infanta Sofia, 28702 Madrid, SpainURSalud Laboratory, Hospital Universitario Infanta Sofia, 28702 Madrid, SpainURSalud Laboratory, Hospital Universitario Infanta Sofia, 28702 Madrid, SpainBackground: Monitoring of measurable residual disease (MRD) requires highly sensitive flow cytometry protocols to provide an accurate prediction of shorter progression-free survival. High assay sensitivity generally requires rapid processing to avoid cell loss from small bone marrow sample volumes, but this requirement conflicts with the need in most clinical cytometry laboratories for long processing and acquisition times, especially when multiple MRD studies coincide on the same day. Methods: The proposed protocol was applied to 226 human bone marrow and 45 peripheral blood samples submitted for the study of MRD or the detection of rare cells. Samples were processed within 24 h of extraction and acquired with an eight-color flow cytometer. Results: The FACSLyse-Bulk protocol allows for the labelling of millions of cells in under 90 min in small sample volumes without affecting the FSC/SSC pattern or antigen expression, and it also allows antigens to be fixed to the membrane, thus avoiding the capping phenomenon. Conclusions: The proposed protocol would allow clinical flow cytometry laboratories to perform MRD studies in house and easily achieve a limit of detection and limit of quantification <0.001%, thus avoiding the need to outsource analysis to specialized cytometry laboratories.https://www.mdpi.com/2079-9721/12/12/338measurable residual diseasehematologyleukemialymphomaflow cytometrylimit of detection
spellingShingle María Beatriz Álvarez Flores
María Sopeña Corvinos
Raquel Guillén Santos
Fernando Cava Valenciano
High-Sensitivity Flow Cytometry for the Reliable Detection of Measurable Residual Disease in Hematological Malignancies in Clinical Laboratories
Diseases
measurable residual disease
hematology
leukemia
lymphoma
flow cytometry
limit of detection
title High-Sensitivity Flow Cytometry for the Reliable Detection of Measurable Residual Disease in Hematological Malignancies in Clinical Laboratories
title_full High-Sensitivity Flow Cytometry for the Reliable Detection of Measurable Residual Disease in Hematological Malignancies in Clinical Laboratories
title_fullStr High-Sensitivity Flow Cytometry for the Reliable Detection of Measurable Residual Disease in Hematological Malignancies in Clinical Laboratories
title_full_unstemmed High-Sensitivity Flow Cytometry for the Reliable Detection of Measurable Residual Disease in Hematological Malignancies in Clinical Laboratories
title_short High-Sensitivity Flow Cytometry for the Reliable Detection of Measurable Residual Disease in Hematological Malignancies in Clinical Laboratories
title_sort high sensitivity flow cytometry for the reliable detection of measurable residual disease in hematological malignancies in clinical laboratories
topic measurable residual disease
hematology
leukemia
lymphoma
flow cytometry
limit of detection
url https://www.mdpi.com/2079-9721/12/12/338
work_keys_str_mv AT mariabeatrizalvarezflores highsensitivityflowcytometryforthereliabledetectionofmeasurableresidualdiseaseinhematologicalmalignanciesinclinicallaboratories
AT mariasopenacorvinos highsensitivityflowcytometryforthereliabledetectionofmeasurableresidualdiseaseinhematologicalmalignanciesinclinicallaboratories
AT raquelguillensantos highsensitivityflowcytometryforthereliabledetectionofmeasurableresidualdiseaseinhematologicalmalignanciesinclinicallaboratories
AT fernandocavavalenciano highsensitivityflowcytometryforthereliabledetectionofmeasurableresidualdiseaseinhematologicalmalignanciesinclinicallaboratories