Analysis of Commutation Principle and Switching Loss for ANPC Three-level Topology

Aiming at the problem that the unbalanced loss of internal and external transistors in NPC three-level topology affects the output power of power module.This paper introduces two different control methods based on ANPC type three-level topology. According to two different control methods, the state...

Full description

Saved in:
Bibliographic Details
Main Authors: XIE Fei, ZHANG Honghao, ZHOU Xiaoyun
Format: Article
Language:zho
Published: Editorial Office of Control and Information Technology 2022-04-01
Series:Kongzhi Yu Xinxi Jishu
Subjects:
Online Access:http://ctet.csrzic.com/thesisDetails#10.13889/j.issn.2096-5427.2022.02.006
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849224959163891712
author XIE Fei
ZHANG Honghao
ZHOU Xiaoyun
author_facet XIE Fei
ZHANG Honghao
ZHOU Xiaoyun
author_sort XIE Fei
collection DOAJ
description Aiming at the problem that the unbalanced loss of internal and external transistors in NPC three-level topology affects the output power of power module.This paper introduces two different control methods based on ANPC type three-level topology. According to two different control methods, the state and commutation process of each switch device under rectifier and inverter conditions are analyzed in detail. Then, the current waveform flowing through each switch device is simulated according to two different control methods. Loss expression of each switch tube is deduced in detail in combination with the current simulation waveform of each switch device; through quantitative calculation and simulation analysis, the loss of each switching device under different control methods is obtained, and the calculation and simulation results are close, so the loss of each switching device under different control methods can be deduced through similar derivation method. Finally, by comparing loss data of various control strategies, it can be seen that compared with NPC topology three-level structure, ANPC topology combined with certain control algorithm can reduce the device loss to a certain extent, so as to improve the output efficiency of power module.
format Article
id doaj-art-7f12b8b098ce4e8aaae7bddf4d512e5b
institution Kabale University
issn 2096-5427
language zho
publishDate 2022-04-01
publisher Editorial Office of Control and Information Technology
record_format Article
series Kongzhi Yu Xinxi Jishu
spelling doaj-art-7f12b8b098ce4e8aaae7bddf4d512e5b2025-08-25T06:49:33ZzhoEditorial Office of Control and Information TechnologyKongzhi Yu Xinxi Jishu2096-54272022-04-01354225759731Analysis of Commutation Principle and Switching Loss for ANPC Three-level TopologyXIE FeiZHANG HonghaoZHOU XiaoyunAiming at the problem that the unbalanced loss of internal and external transistors in NPC three-level topology affects the output power of power module.This paper introduces two different control methods based on ANPC type three-level topology. According to two different control methods, the state and commutation process of each switch device under rectifier and inverter conditions are analyzed in detail. Then, the current waveform flowing through each switch device is simulated according to two different control methods. Loss expression of each switch tube is deduced in detail in combination with the current simulation waveform of each switch device; through quantitative calculation and simulation analysis, the loss of each switching device under different control methods is obtained, and the calculation and simulation results are close, so the loss of each switching device under different control methods can be deduced through similar derivation method. Finally, by comparing loss data of various control strategies, it can be seen that compared with NPC topology three-level structure, ANPC topology combined with certain control algorithm can reduce the device loss to a certain extent, so as to improve the output efficiency of power module.http://ctet.csrzic.com/thesisDetails#10.13889/j.issn.2096-5427.2022.02.006ANPC three-level topologycommutation pathswitching losssimulation analysis
spellingShingle XIE Fei
ZHANG Honghao
ZHOU Xiaoyun
Analysis of Commutation Principle and Switching Loss for ANPC Three-level Topology
Kongzhi Yu Xinxi Jishu
ANPC three-level topology
commutation path
switching loss
simulation analysis
title Analysis of Commutation Principle and Switching Loss for ANPC Three-level Topology
title_full Analysis of Commutation Principle and Switching Loss for ANPC Three-level Topology
title_fullStr Analysis of Commutation Principle and Switching Loss for ANPC Three-level Topology
title_full_unstemmed Analysis of Commutation Principle and Switching Loss for ANPC Three-level Topology
title_short Analysis of Commutation Principle and Switching Loss for ANPC Three-level Topology
title_sort analysis of commutation principle and switching loss for anpc three level topology
topic ANPC three-level topology
commutation path
switching loss
simulation analysis
url http://ctet.csrzic.com/thesisDetails#10.13889/j.issn.2096-5427.2022.02.006
work_keys_str_mv AT xiefei analysisofcommutationprincipleandswitchinglossforanpcthreeleveltopology
AT zhanghonghao analysisofcommutationprincipleandswitchinglossforanpcthreeleveltopology
AT zhouxiaoyun analysisofcommutationprincipleandswitchinglossforanpcthreeleveltopology