Effect of plateletpheresis on donor variables and platelet yield using three different cell separators: Experience from tertiary care hospital

INTRODUCTION: Platelet collection by apheresis is common nowadays. Many cell separators are available in the market for the same. This study was conducted to study the effect of various donor factors on platelet yield and the effect of different cell separator variables on platelet yield. MATERIALS...

Full description

Saved in:
Bibliographic Details
Main Authors: Sarita Sharma, Sunita Bundas, Nippun Prinja, Amit Sharma, Rachna Narain
Format: Article
Language:English
Published: Wolters Kluwer Medknow Publications 2024-12-01
Series:Asian Journal of Transfusion Science
Subjects:
Online Access:https://journals.lww.com/10.4103/ajts.ajts_104_21
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1841554826317529088
author Sarita Sharma
Sunita Bundas
Nippun Prinja
Amit Sharma
Rachna Narain
author_facet Sarita Sharma
Sunita Bundas
Nippun Prinja
Amit Sharma
Rachna Narain
author_sort Sarita Sharma
collection DOAJ
description INTRODUCTION: Platelet collection by apheresis is common nowadays. Many cell separators are available in the market for the same. This study was conducted to study the effect of various donor factors on platelet yield and the effect of different cell separator variables on platelet yield. MATERIALS AND METHODS: This cross-sectional study was done on 600 healthy apheresis platelet donors from April 2016 to March 2017 using three different cell separators. Donor variables, pre, and post-plateletpheresis hematological parameters, machine variables, platelet yield were observed. RESULTS: Postprocedural decline in hematological variables was seen. A positive correlation was seen with pre-apheresis platelet count, blood volume processed, and product volume. Product volume obtained was highest with COM. TEC. Mean platelet yield was maximally seen in Amicus. CONCLUSION: Main predictors of platelet yield are platelet count and volume processed. Donors with lower hemoglobin had better yields. Higher platelet counts lead to better product hence platelet increment in the patient.
format Article
id doaj-art-7e582a8527ad4155864d7aa5b20f7b67
institution Kabale University
issn 0973-6247
1998-3565
language English
publishDate 2024-12-01
publisher Wolters Kluwer Medknow Publications
record_format Article
series Asian Journal of Transfusion Science
spelling doaj-art-7e582a8527ad4155864d7aa5b20f7b672025-01-08T09:08:32ZengWolters Kluwer Medknow PublicationsAsian Journal of Transfusion Science0973-62471998-35652024-12-0118225225610.4103/ajts.ajts_104_21Effect of plateletpheresis on donor variables and platelet yield using three different cell separators: Experience from tertiary care hospitalSarita SharmaSunita BundasNippun PrinjaAmit SharmaRachna NarainINTRODUCTION: Platelet collection by apheresis is common nowadays. Many cell separators are available in the market for the same. This study was conducted to study the effect of various donor factors on platelet yield and the effect of different cell separator variables on platelet yield. MATERIALS AND METHODS: This cross-sectional study was done on 600 healthy apheresis platelet donors from April 2016 to March 2017 using three different cell separators. Donor variables, pre, and post-plateletpheresis hematological parameters, machine variables, platelet yield were observed. RESULTS: Postprocedural decline in hematological variables was seen. A positive correlation was seen with pre-apheresis platelet count, blood volume processed, and product volume. Product volume obtained was highest with COM. TEC. Mean platelet yield was maximally seen in Amicus. CONCLUSION: Main predictors of platelet yield are platelet count and volume processed. Donors with lower hemoglobin had better yields. Higher platelet counts lead to better product hence platelet increment in the patient.https://journals.lww.com/10.4103/ajts.ajts_104_21cell separatordonor variableshematological parametersmachine variablesplatelet yield
spellingShingle Sarita Sharma
Sunita Bundas
Nippun Prinja
Amit Sharma
Rachna Narain
Effect of plateletpheresis on donor variables and platelet yield using three different cell separators: Experience from tertiary care hospital
Asian Journal of Transfusion Science
cell separator
donor variables
hematological parameters
machine variables
platelet yield
title Effect of plateletpheresis on donor variables and platelet yield using three different cell separators: Experience from tertiary care hospital
title_full Effect of plateletpheresis on donor variables and platelet yield using three different cell separators: Experience from tertiary care hospital
title_fullStr Effect of plateletpheresis on donor variables and platelet yield using three different cell separators: Experience from tertiary care hospital
title_full_unstemmed Effect of plateletpheresis on donor variables and platelet yield using three different cell separators: Experience from tertiary care hospital
title_short Effect of plateletpheresis on donor variables and platelet yield using three different cell separators: Experience from tertiary care hospital
title_sort effect of plateletpheresis on donor variables and platelet yield using three different cell separators experience from tertiary care hospital
topic cell separator
donor variables
hematological parameters
machine variables
platelet yield
url https://journals.lww.com/10.4103/ajts.ajts_104_21
work_keys_str_mv AT saritasharma effectofplateletpheresisondonorvariablesandplateletyieldusingthreedifferentcellseparatorsexperiencefromtertiarycarehospital
AT sunitabundas effectofplateletpheresisondonorvariablesandplateletyieldusingthreedifferentcellseparatorsexperiencefromtertiarycarehospital
AT nippunprinja effectofplateletpheresisondonorvariablesandplateletyieldusingthreedifferentcellseparatorsexperiencefromtertiarycarehospital
AT amitsharma effectofplateletpheresisondonorvariablesandplateletyieldusingthreedifferentcellseparatorsexperiencefromtertiarycarehospital
AT rachnanarain effectofplateletpheresisondonorvariablesandplateletyieldusingthreedifferentcellseparatorsexperiencefromtertiarycarehospital