Evaluation the Effectiveness of Sayasept HI and Surfosept Instrument Disinfection Solutions on Rotary Files

Introduction: The present study was conducted with the aim of determining the effectiveness of Sayasept-HI and Surfosept-Instrument disinfectant solutions on dental equipment. Methods: In this laboratory study, 30 patients were selected and 4 rotary files were considered for each patient. The rotary...

Full description

Saved in:
Bibliographic Details
Main Authors: Mansoure Velayati Hoshang, Nazanin Ataee, Masoud Chaboksavar, Saleh Sabbaghi
Format: Article
Language:fas
Published: Shahid Sadoughi University of Medical Sciences 2024-12-01
Series:Majallah-i Dānishgāh-i ’Ulūm-i Pizishkī-i Shahīd Ṣadūqī Yazd
Subjects:
Online Access:http://jssu.ssu.ac.ir/article-1-6249-en.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1846129471783960576
author Mansoure Velayati Hoshang
Nazanin Ataee
Masoud Chaboksavar
Saleh Sabbaghi
author_facet Mansoure Velayati Hoshang
Nazanin Ataee
Masoud Chaboksavar
Saleh Sabbaghi
author_sort Mansoure Velayati Hoshang
collection DOAJ
description Introduction: The present study was conducted with the aim of determining the effectiveness of Sayasept-HI and Surfosept-Instrument disinfectant solutions on dental equipment. Methods: In this laboratory study, 30 patients were selected and 4 rotary files were considered for each patient. The rotary files that were infected with oral microflora were transferred to the laboratory, and in 4 separate categories, including the positive control as a control of contamination, disinfected by Deconex as a negative control, and disinfected by Sayasept-HI and Surfosept-instrument disinfectants. Then sampling of the surfaces of this tool was done by sterile cotton swap. Infected swaps were placed in thioglycolate enrichment medium. Turbidity measurement and then culture of the samples were done on blood agar, Eosin Methylene-Blue and chocolate agar culture media. After the heating time, the grown colonies were counted. The results were analyzed by Mann-Whitney test in SPSS version 16 statistical software. Results: The results showed that no bacterial growth was observed in the two test groups that contained antimicrobial solutions, but in the samples of the control group, the culture results were positive and there was a significant difference between the number of bacterial colonies before and after disinfection with each of the two disinfectant solutions was present (P<0.0001), but there was no difference in terms of disinfection between the two test solutions (P>0.05 ). Conclusion: Both surfosept Instrument and Sayasept HI solutions showed a significant effect in the amount of bacterial colony reduction compared to the control group, and without any superiority over each other, the ability to destroy the bacterial species of their effect spectrum and disinfect the equipment.
format Article
id doaj-art-7dfd15470fe348afa4c9a13c3843859c
institution Kabale University
issn 2228-5741
2228-5733
language fas
publishDate 2024-12-01
publisher Shahid Sadoughi University of Medical Sciences
record_format Article
series Majallah-i Dānishgāh-i ’Ulūm-i Pizishkī-i Shahīd Ṣadūqī Yazd
spelling doaj-art-7dfd15470fe348afa4c9a13c3843859c2024-12-10T05:29:14ZfasShahid Sadoughi University of Medical SciencesMajallah-i Dānishgāh-i ’Ulūm-i Pizishkī-i Shahīd Ṣadūqī Yazd2228-57412228-57332024-12-0132982128225Evaluation the Effectiveness of Sayasept HI and Surfosept Instrument Disinfection Solutions on Rotary FilesMansoure Velayati Hoshang0Nazanin Ataee1Masoud Chaboksavar2Saleh Sabbaghi3 Biology Department, Kavian Institute of Higher Education, Mashhad, Iran. Biology Department, Kavian Institute of Higher Education, Mashhad, Iran. Biology Department, Kavian Institute of Higher Education, Mashhad, Iran. Department of Endodontics, Faculty of Dentistry, Hamadan University of Medical Sciences, Iran. Introduction: The present study was conducted with the aim of determining the effectiveness of Sayasept-HI and Surfosept-Instrument disinfectant solutions on dental equipment. Methods: In this laboratory study, 30 patients were selected and 4 rotary files were considered for each patient. The rotary files that were infected with oral microflora were transferred to the laboratory, and in 4 separate categories, including the positive control as a control of contamination, disinfected by Deconex as a negative control, and disinfected by Sayasept-HI and Surfosept-instrument disinfectants. Then sampling of the surfaces of this tool was done by sterile cotton swap. Infected swaps were placed in thioglycolate enrichment medium. Turbidity measurement and then culture of the samples were done on blood agar, Eosin Methylene-Blue and chocolate agar culture media. After the heating time, the grown colonies were counted. The results were analyzed by Mann-Whitney test in SPSS version 16 statistical software. Results: The results showed that no bacterial growth was observed in the two test groups that contained antimicrobial solutions, but in the samples of the control group, the culture results were positive and there was a significant difference between the number of bacterial colonies before and after disinfection with each of the two disinfectant solutions was present (P<0.0001), but there was no difference in terms of disinfection between the two test solutions (P>0.05 ). Conclusion: Both surfosept Instrument and Sayasept HI solutions showed a significant effect in the amount of bacterial colony reduction compared to the control group, and without any superiority over each other, the ability to destroy the bacterial species of their effect spectrum and disinfect the equipment.http://jssu.ssu.ac.ir/article-1-6249-en.pdfsayasept hiantibacterialsurfosept instrumentrotary file
spellingShingle Mansoure Velayati Hoshang
Nazanin Ataee
Masoud Chaboksavar
Saleh Sabbaghi
Evaluation the Effectiveness of Sayasept HI and Surfosept Instrument Disinfection Solutions on Rotary Files
Majallah-i Dānishgāh-i ’Ulūm-i Pizishkī-i Shahīd Ṣadūqī Yazd
sayasept hi
antibacterial
surfosept instrument
rotary file
title Evaluation the Effectiveness of Sayasept HI and Surfosept Instrument Disinfection Solutions on Rotary Files
title_full Evaluation the Effectiveness of Sayasept HI and Surfosept Instrument Disinfection Solutions on Rotary Files
title_fullStr Evaluation the Effectiveness of Sayasept HI and Surfosept Instrument Disinfection Solutions on Rotary Files
title_full_unstemmed Evaluation the Effectiveness of Sayasept HI and Surfosept Instrument Disinfection Solutions on Rotary Files
title_short Evaluation the Effectiveness of Sayasept HI and Surfosept Instrument Disinfection Solutions on Rotary Files
title_sort evaluation the effectiveness of sayasept hi and surfosept instrument disinfection solutions on rotary files
topic sayasept hi
antibacterial
surfosept instrument
rotary file
url http://jssu.ssu.ac.ir/article-1-6249-en.pdf
work_keys_str_mv AT mansourevelayatihoshang evaluationtheeffectivenessofsayasepthiandsurfoseptinstrumentdisinfectionsolutionsonrotaryfiles
AT nazaninataee evaluationtheeffectivenessofsayasepthiandsurfoseptinstrumentdisinfectionsolutionsonrotaryfiles
AT masoudchaboksavar evaluationtheeffectivenessofsayasepthiandsurfoseptinstrumentdisinfectionsolutionsonrotaryfiles
AT salehsabbaghi evaluationtheeffectivenessofsayasepthiandsurfoseptinstrumentdisinfectionsolutionsonrotaryfiles