PSO-GWO Optimized Fractional Order PID Based Hybrid Shunt Active Power Filter for Power Quality Improvements
This paper presents a Hybrid Shunt Active Power Filter (HSAPF) optimized by hybrid Particle Swarm Optimization-Grey Wolf Optimization (PSO-GWO) and Fractional Order Proportional-Integral-Derivative Controller (FOPIDC) for reactive power and harmonic compensation under balance and unbalance loading c...
Saved in:
Main Authors: | Alok Kumar Mishra, Soumya Ranjan Das, Prakash K. Ray, Ranjan Kumar Mallick, Asit Mohanty, Dillip K. Mishra |
---|---|
Format: | Article |
Language: | English |
Published: |
IEEE
2020-01-01
|
Series: | IEEE Access |
Subjects: | |
Online Access: | https://ieeexplore.ieee.org/document/9069960/ |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Similar Items
-
Maximizing Energy Output of Photovoltaic Systems: Hybrid PSO-GWO-CS Optimization Approach
by: Hassan S. Ahmed, et al.
Published: (2023-09-01) -
A Modified Grey Wolf Algorithm with Applications to Engineering
by: Vahid Mahboub
Published: (2024-04-01) -
Allocation of Series Capacitors Bank in Electric Power Distribution Systems
by: Patrick Michael Motta Correa, et al.
Published: (2025-02-01) -
Modelling and Extraction of Current Harmonic Components based on Instantaneous Power Theory for Shunt Active Filter under Weak Grid
by: Farzad Sajadi, et al.
Published: (2024-04-01) -
GENERALIZED DEFINITION OF THE APPARENT POWER AND ENERGY-EFFICIENT STRATEGIES OF ACTIVE FILTRATION IN THE REDUCED COORDINATE BASE OF A MULTIPHASE POWER SUPPLY SYSTEM
by: М.Ю. Артеменко, et al.
Published: (2025-01-01)