Expulsion of Pore Water from MCM-41 and SBA-16 and the Enthalpy Change of Melting of Water

Expulsion of pore water from the cylindrical pores of MCM-41 and cage-like pores of SBA-16 was studied for the cooling process. It was observed in MCM-41 just above the capillary full filling. In SBA-16 samples, it only appeared for the fully hydrated sample exposed to the saturated vapour pressure,...

Full description

Saved in:
Bibliographic Details
Main Authors: S. Kittaka, T. Urabe, I. Tominaga
Format: Article
Language:English
Published: SAGE Publishing 2015-11-01
Series:Adsorption Science & Technology
Online Access:https://doi.org/10.1260/0263-6174.33.9.749
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Expulsion of pore water from the cylindrical pores of MCM-41 and cage-like pores of SBA-16 was studied for the cooling process. It was observed in MCM-41 just above the capillary full filling. In SBA-16 samples, it only appeared for the fully hydrated sample exposed to the saturated vapour pressure, P 0 . When the pore remained hydrated below P 0 , expulsion of water was not observed. This is explained by the fact that expanded water fills the outermost vacant spherical pores at the particle surface. When an SBA-16 particle was fully wetted with liquid water, the freezing temperature of the pore water decreased slightly. This was caused by the pressure increase derived from occlusion of pore water with surrounding frozen ice. This form of water occlusion should be common in nature at low temperatures (biological cells, liposomes, porous stone, etc.) and was clearly identified in a well-defined porous system.
ISSN:0263-6174
2048-4038