Establishment of a method for detecting the potency of recombinant human coagulation factor Ⅶa for injection

[Objective] To establish a method for detecting the potency of recombinant human coagulation factor Ⅶa for injection. [Methods] By adding the sample and factor Ⅶ deficient plasma to the sample cup and activating the reaction with prothrombin time assay reagent (PT reagent), the coagulation time of t...

Full description

Saved in:
Bibliographic Details
Main Authors: WU Rong, WANG Liping, LANG Jinye, ZHU Yue, ZHOU Jing, LIU Xun, NI Jing, ZHOU Shunbo, DING Yaling
Format: Article
Language:zho
Published: Institute of Blood Transfusion of Chinese Academy of Medical Sciences 2025-03-01
Series:Zhongguo shuxue zazhi
Subjects:
Online Access:https://www.cjbt.cn/thesisDetails#10.13303/j.cjbt.issn.1004-549x.2025.03.017&lang=en
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:[Objective] To establish a method for detecting the potency of recombinant human coagulation factor Ⅶa for injection. [Methods] By adding the sample and factor Ⅶ deficient plasma to the sample cup and activating the reaction with prothrombin time assay reagent (PT reagent), the coagulation time of the sample was determined by the change in magnetic bead swing amplitude in the sample cup. The logarithm of coagulation time was inversely proportional to the logarithm of human factor Ⅶa potency. [Results] Under the experimental conditions, the specificity of the methodology was evaluated through spiked recovery, and the recovery rates ranged from 90.0% to 110.0%. Within the range from 0.125 to 1.000 IU/mL, there was a good linear response between the potency and coagulation time of the standard and sample, with correlation coefficients r>0.99. As for the accuracy and repeatability, the recovery rates of various concentrations detected in the stock solution were 101.0%, 100.0% and 112.0%, respectively, with RSD values of 2.6%, 4.0% and 0.0%, respectively. The recovery rates of various concentrations in finished product testing were 104.0%, 94.7% and 112.0%, respectively, with RSD values of 1.9%, 2.4% and 0.0%, respectively. As for the intermediate precision, the RSD were 4.5% and 3.7%, respectively. After treated with sample diluent, the sample was tested at room temperature for 6 hours and still exhibited relatively stable biological activity. [Conclusion] This detection method is accurate, stable, easy to operate and highly automated, and is suitable for detecting the potency of recombinant human coagulation factor Ⅶa for Injection.
ISSN:1004-549X