Fit accuracy and fracture resistance evaluation of advanced lithium disilicate crowns (in- vitro study)

Abstract Background Increasing demand for durable and aesthetically pleasing dental restorations, including laminates, inlays, onlays, and crowns, has led to advancements in all-ceramic systems, particularly with the development of advanced lithium disilicate materials. However, limited data on the...

Full description

Saved in:
Bibliographic Details
Main Authors: Amro Khalil Fayed, Amir Shoukry Azer, Rewaa Gaber AboElhassan
Format: Article
Language:English
Published: BMC 2025-01-01
Series:BMC Oral Health
Subjects:
Online Access:https://doi.org/10.1186/s12903-024-05325-z
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1841544235614994432
author Amro Khalil Fayed
Amir Shoukry Azer
Rewaa Gaber AboElhassan
author_facet Amro Khalil Fayed
Amir Shoukry Azer
Rewaa Gaber AboElhassan
author_sort Amro Khalil Fayed
collection DOAJ
description Abstract Background Increasing demand for durable and aesthetically pleasing dental restorations, including laminates, inlays, onlays, and crowns, has led to advancements in all-ceramic systems, particularly with the development of advanced lithium disilicate materials. However, limited data on the fit accuracy and fracture resistance of these materials restricts their wider application in clinical restorative practices. Aim of the study This in vitro study aims to compare the marginal and internal fit, assess the fracture resistance, and evaluate the failure modes of crowns fabricated from advanced and conventional lithium disilicate materials. Materials and methods Thirty two (n = 32) crowns were fabricated and categorized into two groups based on the material used: Group (CT), where crowns were milled from CEREC Tessera (n = 16), and Group (EM), where crowns were milled from IPS e.max CAD (n = 16) using a CAD/CAM system. The marginal and internal fit were assessed digitally via a triple scan protocol. All samples were subjected to a fracture resistance test with a universal testing machine, followed by an analysis of failure modes under a stereomicroscope. Results In the evaluation of marginal, internal and total gaps, CEREC Tessera (CT) showed slightly better fit with lower gap values compared to e.max CAD (EM). However, an independent samples t-test indicated no statistically significant differences between the two groups (p = 0.141, p = 0.471). For fracture resistance (N), the CT group demonstrated higher values than the EM group; however, the independent samples t-test indicated no statistically significant difference (p = 0.053). Additionally, the Chi-squared test with Monte Carlo correction revealed no statistically significant differences in the modes of fracture between the two groups (p = 0.484). Conclusion Considering the limitations of this study, advanced lithium disilicate crowns demonstrated better results in terms of marginal fit, internal adaptation, and fracture resistance compared to traditional lithium disilicate crowns; however, the differences were not statistically significant. Both materials exhibited comparable fracture patterns.
format Article
id doaj-art-653773c2fab145518171890176e8bdf4
institution Kabale University
issn 1472-6831
language English
publishDate 2025-01-01
publisher BMC
record_format Article
series BMC Oral Health
spelling doaj-art-653773c2fab145518171890176e8bdf42025-01-12T12:42:08ZengBMCBMC Oral Health1472-68312025-01-0125111210.1186/s12903-024-05325-zFit accuracy and fracture resistance evaluation of advanced lithium disilicate crowns (in- vitro study)Amro Khalil Fayed0Amir Shoukry Azer1Rewaa Gaber AboElhassan2Division of Fixed Prosthodontics, Conservative Dentistry Department, Faculty of Dentistry, Alexandria UniversityDivision of Fixed Prosthodontics, Conservative Dentistry Department, Faculty of Dentistry, Alexandria UniversityDivision of Fixed Prosthodontics, Conservative Dentistry Department, Faculty of Dentistry, Alexandria UniversityAbstract Background Increasing demand for durable and aesthetically pleasing dental restorations, including laminates, inlays, onlays, and crowns, has led to advancements in all-ceramic systems, particularly with the development of advanced lithium disilicate materials. However, limited data on the fit accuracy and fracture resistance of these materials restricts their wider application in clinical restorative practices. Aim of the study This in vitro study aims to compare the marginal and internal fit, assess the fracture resistance, and evaluate the failure modes of crowns fabricated from advanced and conventional lithium disilicate materials. Materials and methods Thirty two (n = 32) crowns were fabricated and categorized into two groups based on the material used: Group (CT), where crowns were milled from CEREC Tessera (n = 16), and Group (EM), where crowns were milled from IPS e.max CAD (n = 16) using a CAD/CAM system. The marginal and internal fit were assessed digitally via a triple scan protocol. All samples were subjected to a fracture resistance test with a universal testing machine, followed by an analysis of failure modes under a stereomicroscope. Results In the evaluation of marginal, internal and total gaps, CEREC Tessera (CT) showed slightly better fit with lower gap values compared to e.max CAD (EM). However, an independent samples t-test indicated no statistically significant differences between the two groups (p = 0.141, p = 0.471). For fracture resistance (N), the CT group demonstrated higher values than the EM group; however, the independent samples t-test indicated no statistically significant difference (p = 0.053). Additionally, the Chi-squared test with Monte Carlo correction revealed no statistically significant differences in the modes of fracture between the two groups (p = 0.484). Conclusion Considering the limitations of this study, advanced lithium disilicate crowns demonstrated better results in terms of marginal fit, internal adaptation, and fracture resistance compared to traditional lithium disilicate crowns; however, the differences were not statistically significant. Both materials exhibited comparable fracture patterns.https://doi.org/10.1186/s12903-024-05325-zCrownsMarginal adaptationInternal fitFracture resistanceCEREC tesseraIPS e.max Cad
spellingShingle Amro Khalil Fayed
Amir Shoukry Azer
Rewaa Gaber AboElhassan
Fit accuracy and fracture resistance evaluation of advanced lithium disilicate crowns (in- vitro study)
BMC Oral Health
Crowns
Marginal adaptation
Internal fit
Fracture resistance
CEREC tessera
IPS e.max Cad
title Fit accuracy and fracture resistance evaluation of advanced lithium disilicate crowns (in- vitro study)
title_full Fit accuracy and fracture resistance evaluation of advanced lithium disilicate crowns (in- vitro study)
title_fullStr Fit accuracy and fracture resistance evaluation of advanced lithium disilicate crowns (in- vitro study)
title_full_unstemmed Fit accuracy and fracture resistance evaluation of advanced lithium disilicate crowns (in- vitro study)
title_short Fit accuracy and fracture resistance evaluation of advanced lithium disilicate crowns (in- vitro study)
title_sort fit accuracy and fracture resistance evaluation of advanced lithium disilicate crowns in vitro study
topic Crowns
Marginal adaptation
Internal fit
Fracture resistance
CEREC tessera
IPS e.max Cad
url https://doi.org/10.1186/s12903-024-05325-z
work_keys_str_mv AT amrokhalilfayed fitaccuracyandfractureresistanceevaluationofadvancedlithiumdisilicatecrownsinvitrostudy
AT amirshoukryazer fitaccuracyandfractureresistanceevaluationofadvancedlithiumdisilicatecrownsinvitrostudy
AT rewaagaberaboelhassan fitaccuracyandfractureresistanceevaluationofadvancedlithiumdisilicatecrownsinvitrostudy