Assessing PET performance, image quality, and attenuation correction in the presence of RF coils within a 9.4 T MRI for preclinical simultaneous imaging

Abstract Background This study evaluates the performance of a positron emission tomography (PET) insert combined with a 9.4 Tesla magnetic resonance (MR) imaging system using three different radiofrequency (RF) coils. The impact of the RF coils within the PET field of view (FoV) on key PET performan...

Full description

Saved in:
Bibliographic Details
Main Authors: Claudia Kuntner, Joachim Friske, Andrea Stessl, Martin Haas, Lara Luna Breyer, Thomas Wanek, Marcus Hacker, Thomas Helbich, Ivo Rausch
Format: Article
Language:English
Published: SpringerOpen 2025-07-01
Series:EJNMMI Physics
Subjects:
Online Access:https://doi.org/10.1186/s40658-025-00771-2
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849334413753581568
author Claudia Kuntner
Joachim Friske
Andrea Stessl
Martin Haas
Lara Luna Breyer
Thomas Wanek
Marcus Hacker
Thomas Helbich
Ivo Rausch
author_facet Claudia Kuntner
Joachim Friske
Andrea Stessl
Martin Haas
Lara Luna Breyer
Thomas Wanek
Marcus Hacker
Thomas Helbich
Ivo Rausch
author_sort Claudia Kuntner
collection DOAJ
description Abstract Background This study evaluates the performance of a positron emission tomography (PET) insert combined with a 9.4 Tesla magnetic resonance (MR) imaging system using three different radiofrequency (RF) coils. The impact of the RF coils within the PET field of view (FoV) on key PET performance parameters was carefully examined. Additionally, the accuracy of MR-based attenuation correction (AC) on the quantitative PET results was assessed. Procedures The performance of the PET scanner was assessed according to the NEMA NU 4-2008 standards, focusing on sensitivity, spatial resolution, noise-equivalent count (NEC) rate, and image quality metrics (homogeneity, spillover ratios, and recovery coefficients). These evaluations were conducted with three different RF coils within the PET FoV: a mouse-dedicated coil, a rat-dedicated coil (not optimized for PET), and a big-rat-dedicated coil. Quantitative testing of AC accuracy was also performed using homogeneously filled phantoms of varying sizes and activity levels, comparing images reconstructed with and without AC. Results The peak absolute sensitivity varied depending on the RF coil used, though spatial resolution was unaffected by the presence of the coils. The NEC curve for the mouse phantom peaked at 441.2 kcps at 29.3 MBq with the mouse-dedicated coil. For the rat phantom, NEC was only tested with the rat-dedicated coils, and the NEC peak reached 203.1 kcps at 27.5 MBq with the big-rat-dedicated coil. Activity concentrations in the NEMA image quality phantom were underestimated when standard MR-AC was applied, likely due to the absence of phantom walls in the generated µ-maps. However, for uniformly filled phantoms with wall thicknesses under 1 mm, standard MR-AC provided accurate quantification. Conclusions Overall, the presence of RF coils had only a minor effect on the performance of the PET/MR insert, with the most significant variation observed for the non-PET-optimized coil. Attenuation correction based on generated µ-maps performed well for phantoms with minimal wall thickness.
format Article
id doaj-art-58c9a9cd122a415b8be9f46dac3b05a5
institution Kabale University
issn 2197-7364
language English
publishDate 2025-07-01
publisher SpringerOpen
record_format Article
series EJNMMI Physics
spelling doaj-art-58c9a9cd122a415b8be9f46dac3b05a52025-08-20T03:45:35ZengSpringerOpenEJNMMI Physics2197-73642025-07-0112111710.1186/s40658-025-00771-2Assessing PET performance, image quality, and attenuation correction in the presence of RF coils within a 9.4 T MRI for preclinical simultaneous imagingClaudia Kuntner0Joachim Friske1Andrea Stessl2Martin Haas3Lara Luna Breyer4Thomas Wanek5Marcus Hacker6Thomas Helbich7Ivo Rausch8Preclinical Imaging Lab (PIL), Department of Biomedical Imaging and Image-guided Therapy, Medical University of ViennaPreclinical Imaging Lab (PIL), Department of Biomedical Imaging and Image-guided Therapy, Medical University of ViennaUniversity of Applied ScienceBruker BioSpin Preclinical Imaging Division, Imaging SoftwarePreclinical Imaging Lab (PIL), Department of Biomedical Imaging and Image-guided Therapy, Medical University of ViennaPreclinical Imaging Lab (PIL), Department of Biomedical Imaging and Image-guided Therapy, Medical University of ViennaResearch Platform Medical Imaging (RPMI), Medical University of ViennaResearch Platform Medical Imaging (RPMI), Medical University of ViennaResearch Platform Medical Imaging (RPMI), Medical University of ViennaAbstract Background This study evaluates the performance of a positron emission tomography (PET) insert combined with a 9.4 Tesla magnetic resonance (MR) imaging system using three different radiofrequency (RF) coils. The impact of the RF coils within the PET field of view (FoV) on key PET performance parameters was carefully examined. Additionally, the accuracy of MR-based attenuation correction (AC) on the quantitative PET results was assessed. Procedures The performance of the PET scanner was assessed according to the NEMA NU 4-2008 standards, focusing on sensitivity, spatial resolution, noise-equivalent count (NEC) rate, and image quality metrics (homogeneity, spillover ratios, and recovery coefficients). These evaluations were conducted with three different RF coils within the PET FoV: a mouse-dedicated coil, a rat-dedicated coil (not optimized for PET), and a big-rat-dedicated coil. Quantitative testing of AC accuracy was also performed using homogeneously filled phantoms of varying sizes and activity levels, comparing images reconstructed with and without AC. Results The peak absolute sensitivity varied depending on the RF coil used, though spatial resolution was unaffected by the presence of the coils. The NEC curve for the mouse phantom peaked at 441.2 kcps at 29.3 MBq with the mouse-dedicated coil. For the rat phantom, NEC was only tested with the rat-dedicated coils, and the NEC peak reached 203.1 kcps at 27.5 MBq with the big-rat-dedicated coil. Activity concentrations in the NEMA image quality phantom were underestimated when standard MR-AC was applied, likely due to the absence of phantom walls in the generated µ-maps. However, for uniformly filled phantoms with wall thicknesses under 1 mm, standard MR-AC provided accurate quantification. Conclusions Overall, the presence of RF coils had only a minor effect on the performance of the PET/MR insert, with the most significant variation observed for the non-PET-optimized coil. Attenuation correction based on generated µ-maps performed well for phantoms with minimal wall thickness.https://doi.org/10.1186/s40658-025-00771-2PETPerformanceNEMAQuantitationPET/MRAttenuation
spellingShingle Claudia Kuntner
Joachim Friske
Andrea Stessl
Martin Haas
Lara Luna Breyer
Thomas Wanek
Marcus Hacker
Thomas Helbich
Ivo Rausch
Assessing PET performance, image quality, and attenuation correction in the presence of RF coils within a 9.4 T MRI for preclinical simultaneous imaging
EJNMMI Physics
PET
Performance
NEMA
Quantitation
PET/MR
Attenuation
title Assessing PET performance, image quality, and attenuation correction in the presence of RF coils within a 9.4 T MRI for preclinical simultaneous imaging
title_full Assessing PET performance, image quality, and attenuation correction in the presence of RF coils within a 9.4 T MRI for preclinical simultaneous imaging
title_fullStr Assessing PET performance, image quality, and attenuation correction in the presence of RF coils within a 9.4 T MRI for preclinical simultaneous imaging
title_full_unstemmed Assessing PET performance, image quality, and attenuation correction in the presence of RF coils within a 9.4 T MRI for preclinical simultaneous imaging
title_short Assessing PET performance, image quality, and attenuation correction in the presence of RF coils within a 9.4 T MRI for preclinical simultaneous imaging
title_sort assessing pet performance image quality and attenuation correction in the presence of rf coils within a 9 4 t mri for preclinical simultaneous imaging
topic PET
Performance
NEMA
Quantitation
PET/MR
Attenuation
url https://doi.org/10.1186/s40658-025-00771-2
work_keys_str_mv AT claudiakuntner assessingpetperformanceimagequalityandattenuationcorrectioninthepresenceofrfcoilswithina94tmriforpreclinicalsimultaneousimaging
AT joachimfriske assessingpetperformanceimagequalityandattenuationcorrectioninthepresenceofrfcoilswithina94tmriforpreclinicalsimultaneousimaging
AT andreastessl assessingpetperformanceimagequalityandattenuationcorrectioninthepresenceofrfcoilswithina94tmriforpreclinicalsimultaneousimaging
AT martinhaas assessingpetperformanceimagequalityandattenuationcorrectioninthepresenceofrfcoilswithina94tmriforpreclinicalsimultaneousimaging
AT laralunabreyer assessingpetperformanceimagequalityandattenuationcorrectioninthepresenceofrfcoilswithina94tmriforpreclinicalsimultaneousimaging
AT thomaswanek assessingpetperformanceimagequalityandattenuationcorrectioninthepresenceofrfcoilswithina94tmriforpreclinicalsimultaneousimaging
AT marcushacker assessingpetperformanceimagequalityandattenuationcorrectioninthepresenceofrfcoilswithina94tmriforpreclinicalsimultaneousimaging
AT thomashelbich assessingpetperformanceimagequalityandattenuationcorrectioninthepresenceofrfcoilswithina94tmriforpreclinicalsimultaneousimaging
AT ivorausch assessingpetperformanceimagequalityandattenuationcorrectioninthepresenceofrfcoilswithina94tmriforpreclinicalsimultaneousimaging