Design of a Micro Scale Incinerator as a Solution for Handling Waste in Cisolok Village

The waste problem in Kampung Cigoler RW.03 Cisolok Village is increasingly worrying, with a volume reaching 659,08 kg/day. One of the proposed solutions is a micro-scale incinerator with the main components of a burner, combustion chamber, and filtration system using mineral rocks and activated carb...

Full description

Saved in:
Bibliographic Details
Main Authors: Fahreza Oktava Adam, Arisandi Moch Ichsan, Rohman Fathur, Akmal Islami Lazuardi
Format: Article
Language:English
Published: EDP Sciences 2024-01-01
Series:BIO Web of Conferences
Online Access:https://www.bio-conferences.org/articles/bioconf/pdf/2024/67/bioconf_icobeaf2024_02029.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1841526742577053696
author Fahreza Oktava Adam
Arisandi Moch Ichsan
Rohman Fathur
Akmal Islami Lazuardi
author_facet Fahreza Oktava Adam
Arisandi Moch Ichsan
Rohman Fathur
Akmal Islami Lazuardi
author_sort Fahreza Oktava Adam
collection DOAJ
description The waste problem in Kampung Cigoler RW.03 Cisolok Village is increasingly worrying, with a volume reaching 659,08 kg/day. One of the proposed solutions is a micro-scale incinerator with the main components of a burner, combustion chamber, and filtration system using mineral rocks and activated carbon. The de- sign of this incinerator considers its strength and structural safety factors, to en- sure it can withstand operational loads. Analysis using Autodesk Inventor 2023 software and ASTM A36 material shows that the stress on the incinerator frame is far below the UTS and the material yield limit, indicating that the design is safe and able to withstand the load of components and waste being burned. FEA anal- ysis shows a von Mises stress distribution with a maximum stress of 8,8976 MPa, a maximum displacement of 0,039456 mm and a safety factor of 15ul. The design of this micro-scale incinerator is expected to be an innovative solution for waste management in Cisolok Village, with adequate safety factors based on structural analysis. The incinerator design is safe in terms of structural strength so that the manufacturing process can be carried out. The design that was created has also been calculated to be able to resolve 33,98% of daily waste production.
format Article
id doaj-art-566f7a058f4748c6978f4a84c09a73f0
institution Kabale University
issn 2117-4458
language English
publishDate 2024-01-01
publisher EDP Sciences
record_format Article
series BIO Web of Conferences
spelling doaj-art-566f7a058f4748c6978f4a84c09a73f02025-01-16T11:19:46ZengEDP SciencesBIO Web of Conferences2117-44582024-01-011480202910.1051/bioconf/202414802029bioconf_icobeaf2024_02029Design of a Micro Scale Incinerator as a Solution for Handling Waste in Cisolok VillageFahreza Oktava Adam0Arisandi Moch Ichsan1Rohman Fathur2Akmal Islami Lazuardi3Department of Mechanical Engineering, Universitas Nusa PutraDepartment of Mechanical Engineering, Universitas Nusa PutraDepartment of Mechanical Engineering, Universitas Nusa PutraDepartment of Mechanical Engineering, Universitas Nusa PutraThe waste problem in Kampung Cigoler RW.03 Cisolok Village is increasingly worrying, with a volume reaching 659,08 kg/day. One of the proposed solutions is a micro-scale incinerator with the main components of a burner, combustion chamber, and filtration system using mineral rocks and activated carbon. The de- sign of this incinerator considers its strength and structural safety factors, to en- sure it can withstand operational loads. Analysis using Autodesk Inventor 2023 software and ASTM A36 material shows that the stress on the incinerator frame is far below the UTS and the material yield limit, indicating that the design is safe and able to withstand the load of components and waste being burned. FEA anal- ysis shows a von Mises stress distribution with a maximum stress of 8,8976 MPa, a maximum displacement of 0,039456 mm and a safety factor of 15ul. The design of this micro-scale incinerator is expected to be an innovative solution for waste management in Cisolok Village, with adequate safety factors based on structural analysis. The incinerator design is safe in terms of structural strength so that the manufacturing process can be carried out. The design that was created has also been calculated to be able to resolve 33,98% of daily waste production.https://www.bio-conferences.org/articles/bioconf/pdf/2024/67/bioconf_icobeaf2024_02029.pdf
spellingShingle Fahreza Oktava Adam
Arisandi Moch Ichsan
Rohman Fathur
Akmal Islami Lazuardi
Design of a Micro Scale Incinerator as a Solution for Handling Waste in Cisolok Village
BIO Web of Conferences
title Design of a Micro Scale Incinerator as a Solution for Handling Waste in Cisolok Village
title_full Design of a Micro Scale Incinerator as a Solution for Handling Waste in Cisolok Village
title_fullStr Design of a Micro Scale Incinerator as a Solution for Handling Waste in Cisolok Village
title_full_unstemmed Design of a Micro Scale Incinerator as a Solution for Handling Waste in Cisolok Village
title_short Design of a Micro Scale Incinerator as a Solution for Handling Waste in Cisolok Village
title_sort design of a micro scale incinerator as a solution for handling waste in cisolok village
url https://www.bio-conferences.org/articles/bioconf/pdf/2024/67/bioconf_icobeaf2024_02029.pdf
work_keys_str_mv AT fahrezaoktavaadam designofamicroscaleincineratorasasolutionforhandlingwasteincisolokvillage
AT arisandimochichsan designofamicroscaleincineratorasasolutionforhandlingwasteincisolokvillage
AT rohmanfathur designofamicroscaleincineratorasasolutionforhandlingwasteincisolokvillage
AT akmalislamilazuardi designofamicroscaleincineratorasasolutionforhandlingwasteincisolokvillage