Design of a Micro Scale Incinerator as a Solution for Handling Waste in Cisolok Village
The waste problem in Kampung Cigoler RW.03 Cisolok Village is increasingly worrying, with a volume reaching 659,08 kg/day. One of the proposed solutions is a micro-scale incinerator with the main components of a burner, combustion chamber, and filtration system using mineral rocks and activated carb...
Saved in:
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
EDP Sciences
2024-01-01
|
Series: | BIO Web of Conferences |
Online Access: | https://www.bio-conferences.org/articles/bioconf/pdf/2024/67/bioconf_icobeaf2024_02029.pdf |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
_version_ | 1841526742577053696 |
---|---|
author | Fahreza Oktava Adam Arisandi Moch Ichsan Rohman Fathur Akmal Islami Lazuardi |
author_facet | Fahreza Oktava Adam Arisandi Moch Ichsan Rohman Fathur Akmal Islami Lazuardi |
author_sort | Fahreza Oktava Adam |
collection | DOAJ |
description | The waste problem in Kampung Cigoler RW.03 Cisolok Village is increasingly worrying, with a volume reaching 659,08 kg/day. One of the proposed solutions is a micro-scale incinerator with the main components of a burner, combustion chamber, and filtration system using mineral rocks and activated carbon. The de- sign of this incinerator considers its strength and structural safety factors, to en- sure it can withstand operational loads. Analysis using Autodesk Inventor 2023 software and ASTM A36 material shows that the stress on the incinerator frame is far below the UTS and the material yield limit, indicating that the design is safe and able to withstand the load of components and waste being burned. FEA anal- ysis shows a von Mises stress distribution with a maximum stress of 8,8976 MPa, a maximum displacement of 0,039456 mm and a safety factor of 15ul. The design of this micro-scale incinerator is expected to be an innovative solution for waste management in Cisolok Village, with adequate safety factors based on structural analysis. The incinerator design is safe in terms of structural strength so that the manufacturing process can be carried out. The design that was created has also been calculated to be able to resolve 33,98% of daily waste production. |
format | Article |
id | doaj-art-566f7a058f4748c6978f4a84c09a73f0 |
institution | Kabale University |
issn | 2117-4458 |
language | English |
publishDate | 2024-01-01 |
publisher | EDP Sciences |
record_format | Article |
series | BIO Web of Conferences |
spelling | doaj-art-566f7a058f4748c6978f4a84c09a73f02025-01-16T11:19:46ZengEDP SciencesBIO Web of Conferences2117-44582024-01-011480202910.1051/bioconf/202414802029bioconf_icobeaf2024_02029Design of a Micro Scale Incinerator as a Solution for Handling Waste in Cisolok VillageFahreza Oktava Adam0Arisandi Moch Ichsan1Rohman Fathur2Akmal Islami Lazuardi3Department of Mechanical Engineering, Universitas Nusa PutraDepartment of Mechanical Engineering, Universitas Nusa PutraDepartment of Mechanical Engineering, Universitas Nusa PutraDepartment of Mechanical Engineering, Universitas Nusa PutraThe waste problem in Kampung Cigoler RW.03 Cisolok Village is increasingly worrying, with a volume reaching 659,08 kg/day. One of the proposed solutions is a micro-scale incinerator with the main components of a burner, combustion chamber, and filtration system using mineral rocks and activated carbon. The de- sign of this incinerator considers its strength and structural safety factors, to en- sure it can withstand operational loads. Analysis using Autodesk Inventor 2023 software and ASTM A36 material shows that the stress on the incinerator frame is far below the UTS and the material yield limit, indicating that the design is safe and able to withstand the load of components and waste being burned. FEA anal- ysis shows a von Mises stress distribution with a maximum stress of 8,8976 MPa, a maximum displacement of 0,039456 mm and a safety factor of 15ul. The design of this micro-scale incinerator is expected to be an innovative solution for waste management in Cisolok Village, with adequate safety factors based on structural analysis. The incinerator design is safe in terms of structural strength so that the manufacturing process can be carried out. The design that was created has also been calculated to be able to resolve 33,98% of daily waste production.https://www.bio-conferences.org/articles/bioconf/pdf/2024/67/bioconf_icobeaf2024_02029.pdf |
spellingShingle | Fahreza Oktava Adam Arisandi Moch Ichsan Rohman Fathur Akmal Islami Lazuardi Design of a Micro Scale Incinerator as a Solution for Handling Waste in Cisolok Village BIO Web of Conferences |
title | Design of a Micro Scale Incinerator as a Solution for Handling Waste in Cisolok Village |
title_full | Design of a Micro Scale Incinerator as a Solution for Handling Waste in Cisolok Village |
title_fullStr | Design of a Micro Scale Incinerator as a Solution for Handling Waste in Cisolok Village |
title_full_unstemmed | Design of a Micro Scale Incinerator as a Solution for Handling Waste in Cisolok Village |
title_short | Design of a Micro Scale Incinerator as a Solution for Handling Waste in Cisolok Village |
title_sort | design of a micro scale incinerator as a solution for handling waste in cisolok village |
url | https://www.bio-conferences.org/articles/bioconf/pdf/2024/67/bioconf_icobeaf2024_02029.pdf |
work_keys_str_mv | AT fahrezaoktavaadam designofamicroscaleincineratorasasolutionforhandlingwasteincisolokvillage AT arisandimochichsan designofamicroscaleincineratorasasolutionforhandlingwasteincisolokvillage AT rohmanfathur designofamicroscaleincineratorasasolutionforhandlingwasteincisolokvillage AT akmalislamilazuardi designofamicroscaleincineratorasasolutionforhandlingwasteincisolokvillage |