The practice of testing translucent facades for air and water permeability based on experience in Canada and the USA and the applicability of this experience to the realities of the Russian Federation

Introduction. Current article summarizes North American practices of standard test methods for exterior glazing applications, such as curtain walls, windows and compare these methods with practices exists in Russian Federation.Materials and methods. It was assumed analysis of the testing principles...

Full description

Saved in:
Bibliographic Details
Main Author: S. P. Mihhailenko
Format: Article
Language:English
Published: Moscow State University of Civil Engineering (MGSU) 2024-08-01
Series:Vestnik MGSU
Online Access:https://www.vestnikmgsu.ru/jour/article/view/347
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1841553445804310528
author S. P. Mihhailenko
author_facet S. P. Mihhailenko
author_sort S. P. Mihhailenko
collection DOAJ
description Introduction. Current article summarizes North American practices of standard test methods for exterior glazing applications, such as curtain walls, windows and compare these methods with practices exists in Russian Federation.Materials and methods. It was assumed analysis of the testing principles for curtain walls and windows in Canada and USA, based on the long-term experience of these works and their tests. This article also contains comparison with the existing testing methods in Russian Federation, based on the recently published GOST 70941–2023 “Translucent facade construction. Methods of determination of water permeability under natural conditions”. There is a description of the recommended equipment for testing in a lab and construction site.Results. The article describes required methods of testing, used equipment, safety rules during test development on construction site.Conclusions. The absence of the uniform construction site testing standard for the curtain wall and windows in the Russian Federation can create a situation very similar to that once arose in Vancouver, Canada in the beginning of 90th last century, when a lot of building facades starts leaking (leaky condo in Vancouver) and do not comply with the main purpose of the exterior skin of building — to separate exterior environment from interior and provide to public favorable conditions for living in the building. Unfortunately newly developed GOST 70941–2023 more looks like the description of the facades washing before occupancy, than provides engineering approaches for testing facades and determine resistance to withstand with applicable environmental loads on buildings (wind and rain). It is time, when it is necessary to develop uniform standard for all contractors, who builds curtain wall and windows and how these building skin structures suppose to prevent air or water leakage to the interior of the buildings.
format Article
id doaj-art-4dd3970757c24357b9ddd8623db8a84e
institution Kabale University
issn 1997-0935
2304-6600
language English
publishDate 2024-08-01
publisher Moscow State University of Civil Engineering (MGSU)
record_format Article
series Vestnik MGSU
spelling doaj-art-4dd3970757c24357b9ddd8623db8a84e2025-01-09T08:22:50ZengMoscow State University of Civil Engineering (MGSU)Vestnik MGSU1997-09352304-66002024-08-0119814011412164The practice of testing translucent facades for air and water permeability based on experience in Canada and the USA and the applicability of this experience to the realities of the Russian FederationS. P. MihhailenkoIntroduction. Current article summarizes North American practices of standard test methods for exterior glazing applications, such as curtain walls, windows and compare these methods with practices exists in Russian Federation.Materials and methods. It was assumed analysis of the testing principles for curtain walls and windows in Canada and USA, based on the long-term experience of these works and their tests. This article also contains comparison with the existing testing methods in Russian Federation, based on the recently published GOST 70941–2023 “Translucent facade construction. Methods of determination of water permeability under natural conditions”. There is a description of the recommended equipment for testing in a lab and construction site.Results. The article describes required methods of testing, used equipment, safety rules during test development on construction site.Conclusions. The absence of the uniform construction site testing standard for the curtain wall and windows in the Russian Federation can create a situation very similar to that once arose in Vancouver, Canada in the beginning of 90th last century, when a lot of building facades starts leaking (leaky condo in Vancouver) and do not comply with the main purpose of the exterior skin of building — to separate exterior environment from interior and provide to public favorable conditions for living in the building. Unfortunately newly developed GOST 70941–2023 more looks like the description of the facades washing before occupancy, than provides engineering approaches for testing facades and determine resistance to withstand with applicable environmental loads on buildings (wind and rain). It is time, when it is necessary to develop uniform standard for all contractors, who builds curtain wall and windows and how these building skin structures suppose to prevent air or water leakage to the interior of the buildings.https://www.vestnikmgsu.ru/jour/article/view/347
spellingShingle S. P. Mihhailenko
The practice of testing translucent facades for air and water permeability based on experience in Canada and the USA and the applicability of this experience to the realities of the Russian Federation
Vestnik MGSU
title The practice of testing translucent facades for air and water permeability based on experience in Canada and the USA and the applicability of this experience to the realities of the Russian Federation
title_full The practice of testing translucent facades for air and water permeability based on experience in Canada and the USA and the applicability of this experience to the realities of the Russian Federation
title_fullStr The practice of testing translucent facades for air and water permeability based on experience in Canada and the USA and the applicability of this experience to the realities of the Russian Federation
title_full_unstemmed The practice of testing translucent facades for air and water permeability based on experience in Canada and the USA and the applicability of this experience to the realities of the Russian Federation
title_short The practice of testing translucent facades for air and water permeability based on experience in Canada and the USA and the applicability of this experience to the realities of the Russian Federation
title_sort practice of testing translucent facades for air and water permeability based on experience in canada and the usa and the applicability of this experience to the realities of the russian federation
url https://www.vestnikmgsu.ru/jour/article/view/347
work_keys_str_mv AT spmihhailenko thepracticeoftestingtranslucentfacadesforairandwaterpermeabilitybasedonexperienceincanadaandtheusaandtheapplicabilityofthisexperiencetotherealitiesoftherussianfederation
AT spmihhailenko practiceoftestingtranslucentfacadesforairandwaterpermeabilitybasedonexperienceincanadaandtheusaandtheapplicabilityofthisexperiencetotherealitiesoftherussianfederation