Effect of Installation Error on the Load Sharing Characteristic of Power Three-branching Transmission

The power three- branching transmission system is constituted by the power double- branching transmission system and planetary gear train. In order to reveal the load distribution mechanism of power three- branching transmission system,the each gear torsion angle deformation coordination conditions,...

Full description

Saved in:
Bibliographic Details
Main Authors: Dong Hao, Wang Baobin, Fang Zhou, Zhao Xiaolong
Format: Article
Language:zho
Published: Editorial Office of Journal of Mechanical Transmission 2016-01-01
Series:Jixie chuandong
Subjects:
Online Access:http://www.jxcd.net.cn/thesisDetails#10.16578/j.issn.1004.2539.2016.05.001
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1841547910782648320
author Dong Hao
Wang Baobin
Fang Zhou
Zhao Xiaolong
author_facet Dong Hao
Wang Baobin
Fang Zhou
Zhao Xiaolong
author_sort Dong Hao
collection DOAJ
description The power three- branching transmission system is constituted by the power double- branching transmission system and planetary gear train. In order to reveal the load distribution mechanism of power three- branching transmission system,the each gear torsion angle deformation coordination conditions,moment balance condition and elastic support condition under the power flow closed- loop characteristics are established,the load sharing coefficient is obtained. The influence of the installation error,floating and torsional rigidity on the load sharing characteristic is analyzed. The results show that the installation error is the main factor affecting the load characteristics,and the larger the error,the lower the load performance. The load sharing coefficient fluctuates between 1. 04 and 0. 96 when the sun wheel and the inner ring are floating. The load distribution is within 5%,which can improve the performance of the load.
format Article
id doaj-art-4cd45f4b1c4f4aea91d350e6a1bf1f65
institution Kabale University
issn 1004-2539
language zho
publishDate 2016-01-01
publisher Editorial Office of Journal of Mechanical Transmission
record_format Article
series Jixie chuandong
spelling doaj-art-4cd45f4b1c4f4aea91d350e6a1bf1f652025-01-10T14:17:40ZzhoEditorial Office of Journal of Mechanical TransmissionJixie chuandong1004-25392016-01-01401429923827Effect of Installation Error on the Load Sharing Characteristic of Power Three-branching TransmissionDong HaoWang BaobinFang ZhouZhao XiaolongThe power three- branching transmission system is constituted by the power double- branching transmission system and planetary gear train. In order to reveal the load distribution mechanism of power three- branching transmission system,the each gear torsion angle deformation coordination conditions,moment balance condition and elastic support condition under the power flow closed- loop characteristics are established,the load sharing coefficient is obtained. The influence of the installation error,floating and torsional rigidity on the load sharing characteristic is analyzed. The results show that the installation error is the main factor affecting the load characteristics,and the larger the error,the lower the load performance. The load sharing coefficient fluctuates between 1. 04 and 0. 96 when the sun wheel and the inner ring are floating. The load distribution is within 5%,which can improve the performance of the load.http://www.jxcd.net.cn/thesisDetails#10.16578/j.issn.1004.2539.2016.05.001Installation errorPower three-branchingtransmission Deformationcompatibility FloatingLoad sharing
spellingShingle Dong Hao
Wang Baobin
Fang Zhou
Zhao Xiaolong
Effect of Installation Error on the Load Sharing Characteristic of Power Three-branching Transmission
Jixie chuandong
Installation error
Power three-branching
transmission Deformation
compatibility Floating
Load sharing
title Effect of Installation Error on the Load Sharing Characteristic of Power Three-branching Transmission
title_full Effect of Installation Error on the Load Sharing Characteristic of Power Three-branching Transmission
title_fullStr Effect of Installation Error on the Load Sharing Characteristic of Power Three-branching Transmission
title_full_unstemmed Effect of Installation Error on the Load Sharing Characteristic of Power Three-branching Transmission
title_short Effect of Installation Error on the Load Sharing Characteristic of Power Three-branching Transmission
title_sort effect of installation error on the load sharing characteristic of power three branching transmission
topic Installation error
Power three-branching
transmission Deformation
compatibility Floating
Load sharing
url http://www.jxcd.net.cn/thesisDetails#10.16578/j.issn.1004.2539.2016.05.001
work_keys_str_mv AT donghao effectofinstallationerrorontheloadsharingcharacteristicofpowerthreebranchingtransmission
AT wangbaobin effectofinstallationerrorontheloadsharingcharacteristicofpowerthreebranchingtransmission
AT fangzhou effectofinstallationerrorontheloadsharingcharacteristicofpowerthreebranchingtransmission
AT zhaoxiaolong effectofinstallationerrorontheloadsharingcharacteristicofpowerthreebranchingtransmission