Research on Dry Chemical Detection TechnologyBased on Reflectance Photometry

In response to the issues of insufficient stability and accuracy in dry chemical detection using reflectance photometry, caused by the divergence and multiple internal reflections of the reflected light signal from the sample and the multilayer dry film test strip, a dry chemical reflectance photome...

Full description

Saved in:
Bibliographic Details
Main Authors: Tanghong LU, Juhua HUANG, Chunjiang HUANG, Shuaiding FENG, Lingfeng YOU
Format: Article
Language:zho
Published: Editorial Office of Chinese Journal of Medical Instrumentation 2024-03-01
Series:Zhongguo yiliao qixie zazhi
Subjects:
Online Access:https://zgylqxzz.xml-journal.net/article/doi/10.12455/j.issn.1671-7104.230331
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1846163540685094912
author Tanghong LU
Juhua HUANG
Chunjiang HUANG
Shuaiding FENG
Lingfeng YOU
author_facet Tanghong LU
Juhua HUANG
Chunjiang HUANG
Shuaiding FENG
Lingfeng YOU
author_sort Tanghong LU
collection DOAJ
description In response to the issues of insufficient stability and accuracy in dry chemical detection using reflectance photometry, caused by the divergence and multiple internal reflections of the reflected light signal from the sample and the multilayer dry film test strip, a dry chemical reflectance photometry detection system based on an integrating sphere is designed. Firstly, an integrating sphere device is incorporated to reduce signal divergence and loss, ensuring even detection of the sample's reflected light signal and improving detection stability. Secondly, Light Tools optical simulation analysis is performed, and an integrating sphere detection model is established. Thirdly, the Williams-Clapper equation is employed to correct the error in reflectance density caused by multiple internal reflections, enhancing detection accuracy. Experimental validation demonstrates that the developed integrating sphere-based dry chemical reflectance photometry detection system improves the stability and accuracy of the detection system.
format Article
id doaj-art-429f68e2e1f645e583870f52a9ff0e4b
institution Kabale University
issn 1671-7104
language zho
publishDate 2024-03-01
publisher Editorial Office of Chinese Journal of Medical Instrumentation
record_format Article
series Zhongguo yiliao qixie zazhi
spelling doaj-art-429f68e2e1f645e583870f52a9ff0e4b2024-11-19T06:08:36ZzhoEditorial Office of Chinese Journal of Medical InstrumentationZhongguo yiliao qixie zazhi1671-71042024-03-0148216016610.12455/j.issn.1671-7104.2303312023-0331Research on Dry Chemical Detection TechnologyBased on Reflectance PhotometryTanghong LU0Juhua HUANG1Chunjiang HUANG2Shuaiding FENG3Lingfeng YOU4Institute of Medical Devices, College of Advanced Manufacturing, Nanchang University, Nanchang, 330036Institute of Medical Devices, College of Advanced Manufacturing, Nanchang University, Nanchang, 330036Institute of Medical Devices, College of Advanced Manufacturing, Nanchang University, Nanchang, 330036Institute of Medical Devices, College of Advanced Manufacturing, Nanchang University, Nanchang, 330036Institute of Medical Devices, College of Advanced Manufacturing, Nanchang University, Nanchang, 330036In response to the issues of insufficient stability and accuracy in dry chemical detection using reflectance photometry, caused by the divergence and multiple internal reflections of the reflected light signal from the sample and the multilayer dry film test strip, a dry chemical reflectance photometry detection system based on an integrating sphere is designed. Firstly, an integrating sphere device is incorporated to reduce signal divergence and loss, ensuring even detection of the sample's reflected light signal and improving detection stability. Secondly, Light Tools optical simulation analysis is performed, and an integrating sphere detection model is established. Thirdly, the Williams-Clapper equation is employed to correct the error in reflectance density caused by multiple internal reflections, enhancing detection accuracy. Experimental validation demonstrates that the developed integrating sphere-based dry chemical reflectance photometry detection system improves the stability and accuracy of the detection system.https://zgylqxzz.xml-journal.net/article/doi/10.12455/j.issn.1671-7104.230331reflectance photometrymultiple internal reflectionsintegrating spherewilliams-clapper equation
spellingShingle Tanghong LU
Juhua HUANG
Chunjiang HUANG
Shuaiding FENG
Lingfeng YOU
Research on Dry Chemical Detection TechnologyBased on Reflectance Photometry
Zhongguo yiliao qixie zazhi
reflectance photometry
multiple internal reflections
integrating sphere
williams-clapper equation
title Research on Dry Chemical Detection TechnologyBased on Reflectance Photometry
title_full Research on Dry Chemical Detection TechnologyBased on Reflectance Photometry
title_fullStr Research on Dry Chemical Detection TechnologyBased on Reflectance Photometry
title_full_unstemmed Research on Dry Chemical Detection TechnologyBased on Reflectance Photometry
title_short Research on Dry Chemical Detection TechnologyBased on Reflectance Photometry
title_sort research on dry chemical detection technologybased on reflectance photometry
topic reflectance photometry
multiple internal reflections
integrating sphere
williams-clapper equation
url https://zgylqxzz.xml-journal.net/article/doi/10.12455/j.issn.1671-7104.230331
work_keys_str_mv AT tanghonglu researchondrychemicaldetectiontechnologybasedonreflectancephotometry
AT juhuahuang researchondrychemicaldetectiontechnologybasedonreflectancephotometry
AT chunjianghuang researchondrychemicaldetectiontechnologybasedonreflectancephotometry
AT shuaidingfeng researchondrychemicaldetectiontechnologybasedonreflectancephotometry
AT lingfengyou researchondrychemicaldetectiontechnologybasedonreflectancephotometry