A non-metallic PEEK topology optimization reconstruction implant for large mandibular continuity defects, validated using the MANDYBILATOR apparatus

Abstract In cases of large mandibular continuity defects resulting from malignancy resection, the current standard of care involves using patient-specific/custom titanium reconstruction plates along with autogenous grafts (fibula, scapula, or iliac crest segments). However, when grafts are not feasi...

Full description

Saved in:
Bibliographic Details
Main Authors: Bram B. J. Merema, Frederik K. L. Spijkervet, Joep Kraeima, Max J. H. Witjes
Format: Article
Language:English
Published: Nature Portfolio 2025-01-01
Series:Scientific Reports
Online Access:https://doi.org/10.1038/s41598-024-82964-w
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1841559592424701952
author Bram B. J. Merema
Frederik K. L. Spijkervet
Joep Kraeima
Max J. H. Witjes
author_facet Bram B. J. Merema
Frederik K. L. Spijkervet
Joep Kraeima
Max J. H. Witjes
author_sort Bram B. J. Merema
collection DOAJ
description Abstract In cases of large mandibular continuity defects resulting from malignancy resection, the current standard of care involves using patient-specific/custom titanium reconstruction plates along with autogenous grafts (fibula, scapula, or iliac crest segments). However, when grafts are not feasible or desired, only the reconstruction plate is used to bridge the gap. Unfortunately, metal osteosynthesis and reconstruction plates, including titanium, exhibit adverse effects such as stress-shielding and limitations in accurate postoperative irradiation (especially with proton-beam therapy). To address these issues, in this study we explore, develop and validate a non-metallic solution: a topology-optimized polyetheretherketone (PEEK) load-bearing implant for large non-grafted mandibular continuity defects. In order to thoroughly validate the developed PEEK reconstruction, a dedicated MANDYBILATOR testing apparatus was developed. Using the MANDYBILATOR finite element analysis results of the implant were confirmed and the PEEK implant was mechanically validated for both static and dynamic loading. Results show that the PEEK reconstructed mandible is comparably strong as the unreconstructed mandible and is unlikely to fail due to fatigue. Our PEEK implant design has the mechanical potential to act as a substitute for the current titanium plates used in the reconstruction of continuity defects of the mandible. This may potentially lead to optimised patient-specific reconstructions, with the implants matching the bone’s stiffness and possessing radiolucent properties which are useful for radiographic follow-ups and radiotherapy. Furthermore, the addition of the dynamic/cyclic MANDYBILATOR apparatus allows for more realistic application of the in-vivo loading of the mandible and can provide added insights in biomechanical behaviour of the mandible.
format Article
id doaj-art-3fdcb12b72b247e6b66cbf6c41e03756
institution Kabale University
issn 2045-2322
language English
publishDate 2025-01-01
publisher Nature Portfolio
record_format Article
series Scientific Reports
spelling doaj-art-3fdcb12b72b247e6b66cbf6c41e037562025-01-05T12:20:06ZengNature PortfolioScientific Reports2045-23222025-01-0115111410.1038/s41598-024-82964-wA non-metallic PEEK topology optimization reconstruction implant for large mandibular continuity defects, validated using the MANDYBILATOR apparatusBram B. J. Merema0Frederik K. L. Spijkervet1Joep Kraeima2Max J. H. Witjes3Department of Oral and Maxillofacial Surgery, University Medical Center Groningen, University of GroningenDepartment of Oral and Maxillofacial Surgery, University Medical Center Groningen, University of GroningenDepartment of Oral and Maxillofacial Surgery, University Medical Center Groningen, University of GroningenDepartment of Oral and Maxillofacial Surgery, University Medical Center Groningen, University of GroningenAbstract In cases of large mandibular continuity defects resulting from malignancy resection, the current standard of care involves using patient-specific/custom titanium reconstruction plates along with autogenous grafts (fibula, scapula, or iliac crest segments). However, when grafts are not feasible or desired, only the reconstruction plate is used to bridge the gap. Unfortunately, metal osteosynthesis and reconstruction plates, including titanium, exhibit adverse effects such as stress-shielding and limitations in accurate postoperative irradiation (especially with proton-beam therapy). To address these issues, in this study we explore, develop and validate a non-metallic solution: a topology-optimized polyetheretherketone (PEEK) load-bearing implant for large non-grafted mandibular continuity defects. In order to thoroughly validate the developed PEEK reconstruction, a dedicated MANDYBILATOR testing apparatus was developed. Using the MANDYBILATOR finite element analysis results of the implant were confirmed and the PEEK implant was mechanically validated for both static and dynamic loading. Results show that the PEEK reconstructed mandible is comparably strong as the unreconstructed mandible and is unlikely to fail due to fatigue. Our PEEK implant design has the mechanical potential to act as a substitute for the current titanium plates used in the reconstruction of continuity defects of the mandible. This may potentially lead to optimised patient-specific reconstructions, with the implants matching the bone’s stiffness and possessing radiolucent properties which are useful for radiographic follow-ups and radiotherapy. Furthermore, the addition of the dynamic/cyclic MANDYBILATOR apparatus allows for more realistic application of the in-vivo loading of the mandible and can provide added insights in biomechanical behaviour of the mandible.https://doi.org/10.1038/s41598-024-82964-w
spellingShingle Bram B. J. Merema
Frederik K. L. Spijkervet
Joep Kraeima
Max J. H. Witjes
A non-metallic PEEK topology optimization reconstruction implant for large mandibular continuity defects, validated using the MANDYBILATOR apparatus
Scientific Reports
title A non-metallic PEEK topology optimization reconstruction implant for large mandibular continuity defects, validated using the MANDYBILATOR apparatus
title_full A non-metallic PEEK topology optimization reconstruction implant for large mandibular continuity defects, validated using the MANDYBILATOR apparatus
title_fullStr A non-metallic PEEK topology optimization reconstruction implant for large mandibular continuity defects, validated using the MANDYBILATOR apparatus
title_full_unstemmed A non-metallic PEEK topology optimization reconstruction implant for large mandibular continuity defects, validated using the MANDYBILATOR apparatus
title_short A non-metallic PEEK topology optimization reconstruction implant for large mandibular continuity defects, validated using the MANDYBILATOR apparatus
title_sort non metallic peek topology optimization reconstruction implant for large mandibular continuity defects validated using the mandybilator apparatus
url https://doi.org/10.1038/s41598-024-82964-w
work_keys_str_mv AT brambjmerema anonmetallicpeektopologyoptimizationreconstructionimplantforlargemandibularcontinuitydefectsvalidatedusingthemandybilatorapparatus
AT frederikklspijkervet anonmetallicpeektopologyoptimizationreconstructionimplantforlargemandibularcontinuitydefectsvalidatedusingthemandybilatorapparatus
AT joepkraeima anonmetallicpeektopologyoptimizationreconstructionimplantforlargemandibularcontinuitydefectsvalidatedusingthemandybilatorapparatus
AT maxjhwitjes anonmetallicpeektopologyoptimizationreconstructionimplantforlargemandibularcontinuitydefectsvalidatedusingthemandybilatorapparatus
AT brambjmerema nonmetallicpeektopologyoptimizationreconstructionimplantforlargemandibularcontinuitydefectsvalidatedusingthemandybilatorapparatus
AT frederikklspijkervet nonmetallicpeektopologyoptimizationreconstructionimplantforlargemandibularcontinuitydefectsvalidatedusingthemandybilatorapparatus
AT joepkraeima nonmetallicpeektopologyoptimizationreconstructionimplantforlargemandibularcontinuitydefectsvalidatedusingthemandybilatorapparatus
AT maxjhwitjes nonmetallicpeektopologyoptimizationreconstructionimplantforlargemandibularcontinuitydefectsvalidatedusingthemandybilatorapparatus