A portable analytical chemistry analyzer was used to make field assessments of wild harlequin ducks (Histrionicus histrionicus) in association with telemetry studies of winter survival in Prince William Sound, Alaska. We compared serum chemistry results obtained on-site with results from a tradition...

Full description

Saved in:
Bibliographic Details
Main Authors: Michael K. Stoskopf, Daniel M. Mulcahy, Daniel Esler
Format: Article
Language:English
Published: Wiley 2010-01-01
Series:Veterinary Medicine International
Online Access:http://dx.doi.org/10.4061/2010/418596
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832549570353037312
author Michael K. Stoskopf
Daniel M. Mulcahy
Daniel Esler
author_facet Michael K. Stoskopf
Daniel M. Mulcahy
Daniel Esler
author_sort Michael K. Stoskopf
collection DOAJ
description A portable analytical chemistry analyzer was used to make field assessments of wild harlequin ducks (Histrionicus histrionicus) in association with telemetry studies of winter survival in Prince William Sound, Alaska. We compared serum chemistry results obtained on-site with results from a traditional laboratory. Particular attention was paid to serum glucose and potassium concentrations as potential indicators of high-risk surgical candidates based on evaluation of the field data. The median differential for glucose values (N=82) between methods was 0.6 mmol/L (quartiles 0.3 and 0.9 mmol/L) with the median value higher when assayed on site. Analysis of potassium on site returned a median of 2.7 mmol/L (N=88 ; quartiles 2.4 and 3.0 mmol/L). Serum potassium values were too low for quantitation by the traditional laboratory. Changes in several serum chemistry values following a three-day storm during the study support the value of on site evaluation of serum potassium to identify presurgical patients with increased anesthetic risk.
format Article
id doaj-art-3df0596964cb4ee2a283fdaa12e6f60b
institution Kabale University
issn 2042-0048
language English
publishDate 2010-01-01
publisher Wiley
record_format Article
series Veterinary Medicine International
spelling doaj-art-3df0596964cb4ee2a283fdaa12e6f60b2025-02-03T06:10:52ZengWileyVeterinary Medicine International2042-00482010-01-01201010.4061/2010/418596418596Evaluation of a Portable Automated Serum Chemistry Analyzer for Field Assessment of Harlequin Ducks, Histrionicus histrionicusMichael K. Stoskopf0Daniel M. Mulcahy1Daniel Esler2Environmental Medicine Consortium and Department of Clinical Sciences, College of Veterinary Medicine, North Carolina State University, 4700 Hillsborough Street, Raleigh, NC 27606, USAU.S. Geological Survey, Alaska Science Center, 4210 University Drive, Anchorage, AK 99508, USAU.S. Geological Survey, Alaska Science Center, 4210 University Drive, Anchorage, AK 99508, USAA portable analytical chemistry analyzer was used to make field assessments of wild harlequin ducks (Histrionicus histrionicus) in association with telemetry studies of winter survival in Prince William Sound, Alaska. We compared serum chemistry results obtained on-site with results from a traditional laboratory. Particular attention was paid to serum glucose and potassium concentrations as potential indicators of high-risk surgical candidates based on evaluation of the field data. The median differential for glucose values (N=82) between methods was 0.6 mmol/L (quartiles 0.3 and 0.9 mmol/L) with the median value higher when assayed on site. Analysis of potassium on site returned a median of 2.7 mmol/L (N=88 ; quartiles 2.4 and 3.0 mmol/L). Serum potassium values were too low for quantitation by the traditional laboratory. Changes in several serum chemistry values following a three-day storm during the study support the value of on site evaluation of serum potassium to identify presurgical patients with increased anesthetic risk.http://dx.doi.org/10.4061/2010/418596
spellingShingle Michael K. Stoskopf
Daniel M. Mulcahy
Daniel Esler
Evaluation of a Portable Automated Serum Chemistry Analyzer for Field Assessment of Harlequin Ducks, Histrionicus histrionicus
Veterinary Medicine International
title Evaluation of a Portable Automated Serum Chemistry Analyzer for Field Assessment of Harlequin Ducks, Histrionicus histrionicus
title_full Evaluation of a Portable Automated Serum Chemistry Analyzer for Field Assessment of Harlequin Ducks, Histrionicus histrionicus
title_fullStr Evaluation of a Portable Automated Serum Chemistry Analyzer for Field Assessment of Harlequin Ducks, Histrionicus histrionicus
title_full_unstemmed Evaluation of a Portable Automated Serum Chemistry Analyzer for Field Assessment of Harlequin Ducks, Histrionicus histrionicus
title_short Evaluation of a Portable Automated Serum Chemistry Analyzer for Field Assessment of Harlequin Ducks, Histrionicus histrionicus
title_sort evaluation of a portable automated serum chemistry analyzer for field assessment of harlequin ducks histrionicus histrionicus
url http://dx.doi.org/10.4061/2010/418596
work_keys_str_mv AT michaelkstoskopf evaluationofaportableautomatedserumchemistryanalyzerforfieldassessmentofharlequinduckshistrionicushistrionicus
AT danielmmulcahy evaluationofaportableautomatedserumchemistryanalyzerforfieldassessmentofharlequinduckshistrionicushistrionicus
AT danielesler evaluationofaportableautomatedserumchemistryanalyzerforfieldassessmentofharlequinduckshistrionicushistrionicus