Linearly concentrating solution favors efficient and precise determination of critical pitting chloride concentration
The critical pitting chloride concentration (CPCC) is an essential parameter for the safe service of structural alloys that sensitive to pitting corrosion. Precise lacking and time-consuming frustrates the traditional method (multiple tests), i.e., applies various solutions with different concentrat...
Saved in:
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Elsevier
2025-01-01
|
Series: | Electrochemistry Communications |
Subjects: | |
Online Access: | http://www.sciencedirect.com/science/article/pii/S1388248124002029 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | The critical pitting chloride concentration (CPCC) is an essential parameter for the safe service of structural alloys that sensitive to pitting corrosion. Precise lacking and time-consuming frustrates the traditional method (multiple tests), i.e., applies various solutions with different concentrations and then gradually approaches the real CPCC. Herein, a novel method (single test) was proposed to efficiently and precisely positioning CPCC, i.e., linearly increasing chloride concentration that realized by a peristaltic pump with a high precision drip rate of μL/min. Moreover, a non-linear sensitivity of CPCC to concentrating rate of chloride ion was revealed on CoCrFeNiAlx alloys and the possible mechanism is discussed. |
---|---|
ISSN: | 1388-2481 |