Linearly concentrating solution favors efficient and precise determination of critical pitting chloride concentration

The critical pitting chloride concentration (CPCC) is an essential parameter for the safe service of structural alloys that sensitive to pitting corrosion. Precise lacking and time-consuming frustrates the traditional method (multiple tests), i.e., applies various solutions with different concentrat...

Full description

Saved in:
Bibliographic Details
Main Authors: Jia-Yi Gao, Yang Bai, Cheng-Ping Ye, Xian-Zong Wang
Format: Article
Language:English
Published: Elsevier 2025-01-01
Series:Electrochemistry Communications
Subjects:
Online Access:http://www.sciencedirect.com/science/article/pii/S1388248124002029
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:The critical pitting chloride concentration (CPCC) is an essential parameter for the safe service of structural alloys that sensitive to pitting corrosion. Precise lacking and time-consuming frustrates the traditional method (multiple tests), i.e., applies various solutions with different concentrations and then gradually approaches the real CPCC. Herein, a novel method (single test) was proposed to efficiently and precisely positioning CPCC, i.e., linearly increasing chloride concentration that realized by a peristaltic pump with a high precision drip rate of μL/min. Moreover, a non-linear sensitivity of CPCC to concentrating rate of chloride ion was revealed on CoCrFeNiAlx alloys and the possible mechanism is discussed.
ISSN:1388-2481