New Method To Prevent Contamination In Minimal Invasive Surgery: Usage Of Endoprotector
Objective: To reveal the use of a material called endoprotector designed to prevent contamination in minimally invasive abdominopelvic surgery. Methods: Endoprotector is formed by giving a circular shape to the transparent polyurethane material and passing around it in the form of a pürse-string wi...
Saved in:
Main Authors: | , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Galenos Publishing House
2025-01-01
|
Series: | Gazi Medical Journal |
Subjects: | |
Online Access: | https://gazimedj.com/articles/new-method-to-prevent-contamination-in-minimal-invasive-surgery-usage-of-endoprotector/doi/gmj.2024.3939 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
_version_ | 1841543448839061504 |
---|---|
author | Betül Güzelyüz Server Sezgin Uludağ Engin Hatipoğlu Egemen Özdemir Sefa Ergün Kemal Selçuk Şengün |
author_facet | Betül Güzelyüz Server Sezgin Uludağ Engin Hatipoğlu Egemen Özdemir Sefa Ergün Kemal Selçuk Şengün |
author_sort | Betül Güzelyüz |
collection | DOAJ |
description | Objective: To reveal the use of a material called endoprotector designed to prevent contamination in minimally invasive abdominopelvic surgery.
Methods: Endoprotector is formed by giving a circular shape to the transparent polyurethane material and passing around it in the form of a pürse-string with a surgical suture. This material, which is used in minimally invasive surgeries by inserting it into the abdomen through a trocar hole and laying it on the floor of the operating area, has been in the patent process.
Results: It is characteristic that it is a new product, called endoprotector, and the use of a laparoscopic protective drape is a new technique. At the end of the procedure, the extension of the suture shrinks by pulling from the trocar, and the formed pouch is taken out of the abdomen together with the trocar. Difficulty in removing the trocar from within is the only known shortcoming of the technique.
Conclusion: Endoprotector is designed to prevent contamination in minimally invasive surgery. It reduces peritonitis and intra-abdominal infections, the need for irrigation, and the use of drains, thus shortening postoperative ileus and hospital stay; and predicted to reduce outcomes such as tumor implantation. |
format | Article |
id | doaj-art-2ee792c25d4141368401d91e5df5c5d5 |
institution | Kabale University |
issn | 2147-2092 |
language | English |
publishDate | 2025-01-01 |
publisher | Galenos Publishing House |
record_format | Article |
series | Gazi Medical Journal |
spelling | doaj-art-2ee792c25d4141368401d91e5df5c5d52025-01-13T11:17:15ZengGalenos Publishing HouseGazi Medical Journal2147-20922025-01-013611410.12996/gmj.2024.3939New Method To Prevent Contamination In Minimal Invasive Surgery: Usage Of EndoprotectorBetül Güzelyüz0https://orcid.org/0000-0002-9092-1705Server Sezgin Uludağ1https://orcid.org/0000-0002-0563-3769Engin Hatipoğlu2https://orcid.org/0000-0002-6824-455XEgemen Özdemir3https://orcid.org/0000-0002-8022-8245Sefa Ergün4https://orcid.org/0000-0002-0315-8044Kemal Selçuk Şengün5https://orcid.org/0009-0005-5438-9132Afşin State Hospital, Clinic of General Surgery, Kahramanmaraş, TürkiyeDepartment of General Surgery, İstanbul University-Cerrahpasa, Cerrahpasa Faculty of Medicine, İstanbul, TürkiyeDepartment of General Surgery, İstanbul University-Cerrahpasa, Cerrahpasa Faculty of Medicine, İstanbul, TürkiyeDepartment of General Surgery, İstanbul University-Cerrahpasa, Cerrahpasa Faculty of Medicine, İstanbul, TürkiyeDepartment of General Surgery, İstanbul University-Cerrahpasa, Cerrahpasa Faculty of Medicine, İstanbul, TürkiyeTosya State Hospital, Clinic of General Surgery, Kastamonu, TürkiyeObjective: To reveal the use of a material called endoprotector designed to prevent contamination in minimally invasive abdominopelvic surgery. Methods: Endoprotector is formed by giving a circular shape to the transparent polyurethane material and passing around it in the form of a pürse-string with a surgical suture. This material, which is used in minimally invasive surgeries by inserting it into the abdomen through a trocar hole and laying it on the floor of the operating area, has been in the patent process. Results: It is characteristic that it is a new product, called endoprotector, and the use of a laparoscopic protective drape is a new technique. At the end of the procedure, the extension of the suture shrinks by pulling from the trocar, and the formed pouch is taken out of the abdomen together with the trocar. Difficulty in removing the trocar from within is the only known shortcoming of the technique. Conclusion: Endoprotector is designed to prevent contamination in minimally invasive surgery. It reduces peritonitis and intra-abdominal infections, the need for irrigation, and the use of drains, thus shortening postoperative ileus and hospital stay; and predicted to reduce outcomes such as tumor implantation.https://gazimedj.com/articles/new-method-to-prevent-contamination-in-minimal-invasive-surgery-usage-of-endoprotector/doi/gmj.2024.3939minimally invasive surgeryintra-abdominal contaminationendoprotector |
spellingShingle | Betül Güzelyüz Server Sezgin Uludağ Engin Hatipoğlu Egemen Özdemir Sefa Ergün Kemal Selçuk Şengün New Method To Prevent Contamination In Minimal Invasive Surgery: Usage Of Endoprotector Gazi Medical Journal minimally invasive surgery intra-abdominal contamination endoprotector |
title | New Method To Prevent Contamination In Minimal Invasive Surgery: Usage Of Endoprotector |
title_full | New Method To Prevent Contamination In Minimal Invasive Surgery: Usage Of Endoprotector |
title_fullStr | New Method To Prevent Contamination In Minimal Invasive Surgery: Usage Of Endoprotector |
title_full_unstemmed | New Method To Prevent Contamination In Minimal Invasive Surgery: Usage Of Endoprotector |
title_short | New Method To Prevent Contamination In Minimal Invasive Surgery: Usage Of Endoprotector |
title_sort | new method to prevent contamination in minimal invasive surgery usage of endoprotector |
topic | minimally invasive surgery intra-abdominal contamination endoprotector |
url | https://gazimedj.com/articles/new-method-to-prevent-contamination-in-minimal-invasive-surgery-usage-of-endoprotector/doi/gmj.2024.3939 |
work_keys_str_mv | AT betulguzelyuz newmethodtopreventcontaminationinminimalinvasivesurgeryusageofendoprotector AT serversezginuludag newmethodtopreventcontaminationinminimalinvasivesurgeryusageofendoprotector AT enginhatipoglu newmethodtopreventcontaminationinminimalinvasivesurgeryusageofendoprotector AT egemenozdemir newmethodtopreventcontaminationinminimalinvasivesurgeryusageofendoprotector AT sefaergun newmethodtopreventcontaminationinminimalinvasivesurgeryusageofendoprotector AT kemalselcuksengun newmethodtopreventcontaminationinminimalinvasivesurgeryusageofendoprotector |