Optimization of Aeration for Improving Performance of Hospital Wastewater Treatment Plant

The present descriptive cross-sectional study was conducted by altering the type of blowers in the wastewater treatment system of Abuzar hospital in Ahvaz during the first and second quarters (6 months). In every month, inlet raw wastewater, aeration tank one, and effluent were sampled in one week (...

Full description

Saved in:
Bibliographic Details
Main Authors: Zahra Hezarian, Ehsan Derikvand, Afshin Takdastan
Format: Article
Language:English
Published: OICC Press 2023-07-01
Series:Anthropogenic Pollution
Subjects:
Online Access:http://oiccpress.com/ap/article/view/3494
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1846159311237021696
author Zahra Hezarian
Ehsan Derikvand
Afshin Takdastan
author_facet Zahra Hezarian
Ehsan Derikvand
Afshin Takdastan
author_sort Zahra Hezarian
collection DOAJ
description The present descriptive cross-sectional study was conducted by altering the type of blowers in the wastewater treatment system of Abuzar hospital in Ahvaz during the first and second quarters (6 months). In every month, inlet raw wastewater, aeration tank one, and effluent were sampled in one week (Saturday-Friday), which resulted in harvesting a total of 42 samples. Then, they were assessed based on the techniques provided in the book entitled "standard methods for evaluating water and wastewater", and data were evaluated through employing statistical analyses. The average removal efficiency of total and organic phosphorus, phosphate, and ammonia in the effluent was respectively determined 46.47, 34.45, 18.14, and 68.49 before starting up a new aeration system, which reached 69.36, 76.21, 65.09, and 96.53 during the second period, respectively. In addition, the average concentration of nitrate varied from 21.79 to 44.11 mg/l, while that of nitrite changed from 0.04 to 0.03 mg/l. Further, an increase (39.19 to 67.19%) was observed in the average nitrogen removal efficiency in effluent. Based on the results, EAAS process was efficient in eliminating nitrogen and phosphorus by using the helicoidal pumps of aeration blowers and regulating aeration rate. Thus, aeration plays an effective role in activated sludge systems despite the microorganism diversity in aeration tank sludge. The produced effluent was consistent with Iran national standards in terms of the parameters under study, especially phosphorus and nitrogen, and can be discharged into the environment.
format Article
id doaj-art-284458fd8dcd4f4e94b4d08cec803c6e
institution Kabale University
issn 2783-1736
2588-4646
language English
publishDate 2023-07-01
publisher OICC Press
record_format Article
series Anthropogenic Pollution
spelling doaj-art-284458fd8dcd4f4e94b4d08cec803c6e2024-11-23T11:15:15ZengOICC PressAnthropogenic Pollution2783-17362588-46462023-07-017110.22034/ap.2023.1989523.1158Optimization of Aeration for Improving Performance of Hospital Wastewater Treatment PlantZahra Hezarian0Ehsan Derikvand1Afshin Takdastan2School of Health, Abuzar Hospital, Ahvaz Jundishapur University Of Medical Sciences, Ahvaz,IranAssistant Professor, School of Water Engineering, Islamic Azad University, Shushtar branchDepartment of Environmental Health Engineering, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran; cEnvironmental Technologies Research CenterThe present descriptive cross-sectional study was conducted by altering the type of blowers in the wastewater treatment system of Abuzar hospital in Ahvaz during the first and second quarters (6 months). In every month, inlet raw wastewater, aeration tank one, and effluent were sampled in one week (Saturday-Friday), which resulted in harvesting a total of 42 samples. Then, they were assessed based on the techniques provided in the book entitled "standard methods for evaluating water and wastewater", and data were evaluated through employing statistical analyses. The average removal efficiency of total and organic phosphorus, phosphate, and ammonia in the effluent was respectively determined 46.47, 34.45, 18.14, and 68.49 before starting up a new aeration system, which reached 69.36, 76.21, 65.09, and 96.53 during the second period, respectively. In addition, the average concentration of nitrate varied from 21.79 to 44.11 mg/l, while that of nitrite changed from 0.04 to 0.03 mg/l. Further, an increase (39.19 to 67.19%) was observed in the average nitrogen removal efficiency in effluent. Based on the results, EAAS process was efficient in eliminating nitrogen and phosphorus by using the helicoidal pumps of aeration blowers and regulating aeration rate. Thus, aeration plays an effective role in activated sludge systems despite the microorganism diversity in aeration tank sludge. The produced effluent was consistent with Iran national standards in terms of the parameters under study, especially phosphorus and nitrogen, and can be discharged into the environment.http://oiccpress.com/ap/article/view/3494Activated sludgeEnvironmentExtended aerationNitrogenPhosphorus
spellingShingle Zahra Hezarian
Ehsan Derikvand
Afshin Takdastan
Optimization of Aeration for Improving Performance of Hospital Wastewater Treatment Plant
Anthropogenic Pollution
Activated sludge
Environment
Extended aeration
Nitrogen
Phosphorus
title Optimization of Aeration for Improving Performance of Hospital Wastewater Treatment Plant
title_full Optimization of Aeration for Improving Performance of Hospital Wastewater Treatment Plant
title_fullStr Optimization of Aeration for Improving Performance of Hospital Wastewater Treatment Plant
title_full_unstemmed Optimization of Aeration for Improving Performance of Hospital Wastewater Treatment Plant
title_short Optimization of Aeration for Improving Performance of Hospital Wastewater Treatment Plant
title_sort optimization of aeration for improving performance of hospital wastewater treatment plant
topic Activated sludge
Environment
Extended aeration
Nitrogen
Phosphorus
url http://oiccpress.com/ap/article/view/3494
work_keys_str_mv AT zahrahezarian optimizationofaerationforimprovingperformanceofhospitalwastewatertreatmentplant
AT ehsanderikvand optimizationofaerationforimprovingperformanceofhospitalwastewatertreatmentplant
AT afshintakdastan optimizationofaerationforimprovingperformanceofhospitalwastewatertreatmentplant