Experimental Analysis of Bending Stiffness Characteristics of Grouted Double Mortise-Tenon Joint for Prefabricated Metro Station Structure
The grouted mortise-tenon joint, invented as the connection between the large prefabricated components, is the key to the prefabricated underground structures, and the double-tenon joint is most widely used in the prefabricated metro station structure. This paper conducts characteristic analysis of...
Saved in:
| Main Authors: | , , |
|---|---|
| Format: | Article |
| Language: | English |
| Published: |
Wiley
2021-01-01
|
| Series: | Advances in Civil Engineering |
| Online Access: | http://dx.doi.org/10.1155/2021/9958436 |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
| Summary: | The grouted mortise-tenon joint, invented as the connection between the large prefabricated components, is the key to the prefabricated underground structures, and the double-tenon joint is most widely used in the prefabricated metro station structure. This paper conducts characteristic analysis of bending stiffness with a 1 : 1 prototype test in key working direction of different joint types for grouted double mortise-tenon joint. The results show that the double-tenon joint is characteristic of variable stiffness under different loads. Change laws of double-tenon joint bending stiffness without and with auxiliary pretightening device in tension side and compression side are also discussed. The correlations for calculating double-tenon joint bending stiffness with various axial loads and bending moments are derived at last, which offers the theory foreshadowing of similar joints. |
|---|---|
| ISSN: | 1687-8086 1687-8094 |