Reliability and validity of the hand-held dynamometer “NOD”: a new instrument for assessment of isometric grip strength

Abstract Introduction Hand grip strength (HGS) is an important measure in a physiotherapy assessment and for this purpose it is necessary to have valid and reliable instruments to measure it. In this study we aimed at investigating the reliability, validity, and agreement of the new hand-held dynamo...

Full description

Saved in:
Bibliographic Details
Main Authors: Francesco Sartorio, Lorenzo Lippi, Stefano Vercelli, Federica Gallo, Davide Zanin, Sara Bergesio, Alessandro de Sire, Marco Invernizzi
Format: Article
Language:English
Published: BMC 2025-01-01
Series:BMC Musculoskeletal Disorders
Subjects:
Online Access:https://doi.org/10.1186/s12891-024-08222-2
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1841559868307144704
author Francesco Sartorio
Lorenzo Lippi
Stefano Vercelli
Federica Gallo
Davide Zanin
Sara Bergesio
Alessandro de Sire
Marco Invernizzi
author_facet Francesco Sartorio
Lorenzo Lippi
Stefano Vercelli
Federica Gallo
Davide Zanin
Sara Bergesio
Alessandro de Sire
Marco Invernizzi
author_sort Francesco Sartorio
collection DOAJ
description Abstract Introduction Hand grip strength (HGS) is an important measure in a physiotherapy assessment and for this purpose it is necessary to have valid and reliable instruments to measure it. In this study we aimed at investigating the reliability, validity, and agreement of the new hand-held dynamometer NOD (OT-Bioelettronica, To-Italy) compared to Jamar® hydraulic dynamometer (JD), the gold standard. Methods Fifty healthy subjects were selected; 9 trials for the dominant hand and 9 trials for the non-dominant hand were administrated to each of them: 3 trials of HGS with the JD in rung #3, 3 trials with the JD-adapted-grip (like the NOD one), and 3 trials with NOD. To verify the reliability of NOD, the Intraclass Correlation Coefficient (ICC 3,1) was calculated with a mixed effects model with the addition of adjustment variables (age, gender, dominant / non-dominant limb, trials). The model used single HGS measurements to estimate variance components, so reflecting both degree of correspondence and agreement among devices. To assess concurrent validity NOD was compared to the “gold standard” JD, in terms of ICCs and through Pearson correlation. The agreement between the methods of measurement was calculated with the Limits of Agreement (LoA) and the plots of Bland–Altman. Results All ICCs show high inter-reliability; the results are very similar for both dynamometers. The value of the adjusted ICC of NOD was 0.90. For validity, Pearson correlations of NOD towards JD and JD-adapted-grip were high (r = 0.87 and 0.88). However, the LoA and the plots of Bland–Altman demonstrated that there is no agreement between NOD and JD and between NOD and JD-adapted-grip, with NOD showing lower mean scores than JD. Conclusions NOD is a reliable and valid instrument for HGS. However, even if it cannot be considered interchangeable with JD because there is no agreement between them in free-living adults, NOD is easier to carry than other dynamometers, it has a Bluetooth® connection with a free App and it is a multi-purpose tool that should be considered both in daily practice and in clinical settings.
format Article
id doaj-art-26515b09e90a447f94b8d4eaa6997d30
institution Kabale University
issn 1471-2474
language English
publishDate 2025-01-01
publisher BMC
record_format Article
series BMC Musculoskeletal Disorders
spelling doaj-art-26515b09e90a447f94b8d4eaa6997d302025-01-05T12:05:00ZengBMCBMC Musculoskeletal Disorders1471-24742025-01-0126111110.1186/s12891-024-08222-2Reliability and validity of the hand-held dynamometer “NOD”: a new instrument for assessment of isometric grip strengthFrancesco Sartorio0Lorenzo Lippi1Stefano Vercelli2Federica Gallo3Davide Zanin4Sara Bergesio5Alessandro de Sire6Marco Invernizzi7Division of Physical Medicine and Rehabilitation, ICS Maugeri SPA SB, Institute of Veruno, IRCCSDepartment of Scientific Research, Campus LUdeS, Off-Campus Semmelweis University of BudapestRehabilitation Research Laboratory 2rLab, Department of Business Economics, Health and Social Care, University of Applied Sciences and Arts of SouthernEpidemiology Unit, Local Health Authority 1 of CuneoHand Surgery and Microsurgery Unit, Humanitas - Clinica Fornaca Di SessantExtended Care “Chianoc”Department of Medical and Surgical Sciences, University of Catanzaro “Magna Graecia”Department of Health Sciences, University of Eastern PiedmontAbstract Introduction Hand grip strength (HGS) is an important measure in a physiotherapy assessment and for this purpose it is necessary to have valid and reliable instruments to measure it. In this study we aimed at investigating the reliability, validity, and agreement of the new hand-held dynamometer NOD (OT-Bioelettronica, To-Italy) compared to Jamar® hydraulic dynamometer (JD), the gold standard. Methods Fifty healthy subjects were selected; 9 trials for the dominant hand and 9 trials for the non-dominant hand were administrated to each of them: 3 trials of HGS with the JD in rung #3, 3 trials with the JD-adapted-grip (like the NOD one), and 3 trials with NOD. To verify the reliability of NOD, the Intraclass Correlation Coefficient (ICC 3,1) was calculated with a mixed effects model with the addition of adjustment variables (age, gender, dominant / non-dominant limb, trials). The model used single HGS measurements to estimate variance components, so reflecting both degree of correspondence and agreement among devices. To assess concurrent validity NOD was compared to the “gold standard” JD, in terms of ICCs and through Pearson correlation. The agreement between the methods of measurement was calculated with the Limits of Agreement (LoA) and the plots of Bland–Altman. Results All ICCs show high inter-reliability; the results are very similar for both dynamometers. The value of the adjusted ICC of NOD was 0.90. For validity, Pearson correlations of NOD towards JD and JD-adapted-grip were high (r = 0.87 and 0.88). However, the LoA and the plots of Bland–Altman demonstrated that there is no agreement between NOD and JD and between NOD and JD-adapted-grip, with NOD showing lower mean scores than JD. Conclusions NOD is a reliable and valid instrument for HGS. However, even if it cannot be considered interchangeable with JD because there is no agreement between them in free-living adults, NOD is easier to carry than other dynamometers, it has a Bluetooth® connection with a free App and it is a multi-purpose tool that should be considered both in daily practice and in clinical settings.https://doi.org/10.1186/s12891-024-08222-2Hand grip strengthHealth TechnologyDigital InnovationRehabilitation
spellingShingle Francesco Sartorio
Lorenzo Lippi
Stefano Vercelli
Federica Gallo
Davide Zanin
Sara Bergesio
Alessandro de Sire
Marco Invernizzi
Reliability and validity of the hand-held dynamometer “NOD”: a new instrument for assessment of isometric grip strength
BMC Musculoskeletal Disorders
Hand grip strength
Health Technology
Digital Innovation
Rehabilitation
title Reliability and validity of the hand-held dynamometer “NOD”: a new instrument for assessment of isometric grip strength
title_full Reliability and validity of the hand-held dynamometer “NOD”: a new instrument for assessment of isometric grip strength
title_fullStr Reliability and validity of the hand-held dynamometer “NOD”: a new instrument for assessment of isometric grip strength
title_full_unstemmed Reliability and validity of the hand-held dynamometer “NOD”: a new instrument for assessment of isometric grip strength
title_short Reliability and validity of the hand-held dynamometer “NOD”: a new instrument for assessment of isometric grip strength
title_sort reliability and validity of the hand held dynamometer nod a new instrument for assessment of isometric grip strength
topic Hand grip strength
Health Technology
Digital Innovation
Rehabilitation
url https://doi.org/10.1186/s12891-024-08222-2
work_keys_str_mv AT francescosartorio reliabilityandvalidityofthehandhelddynamometernodanewinstrumentforassessmentofisometricgripstrength
AT lorenzolippi reliabilityandvalidityofthehandhelddynamometernodanewinstrumentforassessmentofisometricgripstrength
AT stefanovercelli reliabilityandvalidityofthehandhelddynamometernodanewinstrumentforassessmentofisometricgripstrength
AT federicagallo reliabilityandvalidityofthehandhelddynamometernodanewinstrumentforassessmentofisometricgripstrength
AT davidezanin reliabilityandvalidityofthehandhelddynamometernodanewinstrumentforassessmentofisometricgripstrength
AT sarabergesio reliabilityandvalidityofthehandhelddynamometernodanewinstrumentforassessmentofisometricgripstrength
AT alessandrodesire reliabilityandvalidityofthehandhelddynamometernodanewinstrumentforassessmentofisometricgripstrength
AT marcoinvernizzi reliabilityandvalidityofthehandhelddynamometernodanewinstrumentforassessmentofisometricgripstrength