A Carbon Monoxide Poisoning Case in Which Hyperbaric Oxygen Therapy Was Not Possible Due to Iatrogenic Pneumothorax after Unnecessary Central Catheterization

Hyperbaric oxygen therapy (HBOT) is used to treat carbon monoxide (CO) poisoning. However, untreated pneumothorax is an absolute contraindication for HBOT. More caution is needed with regard to monoplace hyperbaric chambers, as patient monitoring and life-saving procedures are impossible inside thes...

Full description

Saved in:
Bibliographic Details
Main Authors: Hyung Il Kim, Seong Beom Oh
Format: Article
Language:English
Published: Korean Society of Traumatology 2019-12-01
Series:Journal of Trauma and Injury
Subjects:
Online Access:http://www.jtraumainj.org/upload/pdf/jti-2019-040.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Hyperbaric oxygen therapy (HBOT) is used to treat carbon monoxide (CO) poisoning. However, untreated pneumothorax is an absolute contraindication for HBOT. More caution is needed with regard to monoplace hyperbaric chambers, as patient monitoring and life-saving procedures are impossible inside these chambers. Central catheterization is frequently used for various conditions, but unnecessary catheterization must be avoided because of the risk of infection and mechanical complications. Herein, we describe a case of CO poisoning in which iatrogenic pneumothorax developed after unnecessary subclavian central catheterization. The patient did not need to be catheterized, and HBOT could not be performed because of the pneumothorax. Hence, this case reminds us of basic—but nonetheless important—principles of catheterization.