Validation of Sleep Measurements of an Actigraphy Watch: Instrument Validation Study

BackgroundThe iAide2 (Tokai) physical activity monitoring system includes diverse measurements and wireless features useful to researchers. The iAide2’s sleep measurement capabilities have not been compared to validated sleep measurement standards in any published work....

Full description

Saved in:
Bibliographic Details
Main Authors: Mari Waki, Ryohei Nakada, Kayo Waki, Yuki Ban, Ryo Suzuki, Toshimasa Yamauchi, Masaomi Nangaku, Kazuhiko Ohe
Format: Article
Language:English
Published: JMIR Publications 2025-01-01
Series:JMIR Formative Research
Online Access:https://formative.jmir.org/2025/1/e63529
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1841557139285344256
author Mari Waki
Ryohei Nakada
Kayo Waki
Yuki Ban
Ryo Suzuki
Toshimasa Yamauchi
Masaomi Nangaku
Kazuhiko Ohe
author_facet Mari Waki
Ryohei Nakada
Kayo Waki
Yuki Ban
Ryo Suzuki
Toshimasa Yamauchi
Masaomi Nangaku
Kazuhiko Ohe
author_sort Mari Waki
collection DOAJ
description BackgroundThe iAide2 (Tokai) physical activity monitoring system includes diverse measurements and wireless features useful to researchers. The iAide2’s sleep measurement capabilities have not been compared to validated sleep measurement standards in any published work. ObjectiveWe aimed to assess the iAide2’s sleep duration and total sleep time (TST) measurement performance and perform calibration if needed. MethodsWe performed free-living sleep monitoring in 6 convenience-sampled participants without known sleep disorders recruited from within the Waki DTx Laboratory at the Graduate School of Medicine, University of Tokyo. To assess free-living sleep, we validated the iAide2 against a second actigraph that was previously validated against polysomnography, the MotionWatch 8 (MW8; CamNtech Ltd). The participants wore both devices on the nondominant arm, with the MW8 closest to the hand, all day except when bathing. The MW8 and iAide2 assessments both used the MW8 EVENT-marker button to record bedtime and risetime. For the MW8, MotionWare Software (version 1.4.20; CamNtech Ltd) provided TST, and we calculated sleep duration from the sleep onset and sleep offset provided by the software. We used a similar process with the iAide2, using iAide2 software (version 7.0). We analyzed 64 nights and evaluated the agreement between the iAide2 and the MW8 for sleep duration and TST based on intraclass correlation coefficients (ICCs). ResultsThe absolute ICCs (2-way mixed effects, absolute agreement, single measurement) for sleep duration (0.69, 95% CI –0.07 to 0.91) and TST (0.56, 95% CI –0.07 to 0.82) were moderate. The consistency ICC (2-way mixed effects, consistency, single measurement) was excellent for sleep duration (0.91, 95% CI 0.86-0.95) and moderate for TST (0.78, 95% CI 0.67-0.86). We determined a simple calibration approach. After calibration, the ICCs improved to 0.96 (95% CI 0.94-0.98) for sleep duration and 0.82 (95% CI 0.71-0.88) for TST. The results were not sensitive to the specific participants included, with an ICC range of 0.96-0.97 for sleep duration and 0.79-0.87 for TST when applying our calibration equation to data removing one participant at a time and 0.96-0.97 for sleep duration and 0.79-0.86 for TST when recalibrating while removing one participant at a time. ConclusionsThe measurement errors of the uncalibrated iAide2 for both sleep duration and TST seem too large for them to be useful as absolute measurements, though they could be useful as relative measurements. The measurement errors after calibration are low, and the calibration approach is general and robust, validating the use of iAide2’s sleep measurement functions alongside its other features in physical activity research.
format Article
id doaj-art-1eee011f0efb4040942fcb84cdae371d
institution Kabale University
issn 2561-326X
language English
publishDate 2025-01-01
publisher JMIR Publications
record_format Article
series JMIR Formative Research
spelling doaj-art-1eee011f0efb4040942fcb84cdae371d2025-01-06T15:30:46ZengJMIR PublicationsJMIR Formative Research2561-326X2025-01-019e6352910.2196/63529Validation of Sleep Measurements of an Actigraphy Watch: Instrument Validation StudyMari Wakihttps://orcid.org/0009-0004-3610-4271Ryohei Nakadahttps://orcid.org/0009-0002-8430-875XKayo Wakihttps://orcid.org/0000-0003-0046-2523Yuki Banhttps://orcid.org/0009-0000-1873-8765Ryo Suzukihttps://orcid.org/0000-0002-2965-6906Toshimasa Yamauchihttps://orcid.org/0000-0003-4827-6404Masaomi Nangakuhttps://orcid.org/0000-0001-7401-2934Kazuhiko Ohehttps://orcid.org/0000-0002-4296-9536 BackgroundThe iAide2 (Tokai) physical activity monitoring system includes diverse measurements and wireless features useful to researchers. The iAide2’s sleep measurement capabilities have not been compared to validated sleep measurement standards in any published work. ObjectiveWe aimed to assess the iAide2’s sleep duration and total sleep time (TST) measurement performance and perform calibration if needed. MethodsWe performed free-living sleep monitoring in 6 convenience-sampled participants without known sleep disorders recruited from within the Waki DTx Laboratory at the Graduate School of Medicine, University of Tokyo. To assess free-living sleep, we validated the iAide2 against a second actigraph that was previously validated against polysomnography, the MotionWatch 8 (MW8; CamNtech Ltd). The participants wore both devices on the nondominant arm, with the MW8 closest to the hand, all day except when bathing. The MW8 and iAide2 assessments both used the MW8 EVENT-marker button to record bedtime and risetime. For the MW8, MotionWare Software (version 1.4.20; CamNtech Ltd) provided TST, and we calculated sleep duration from the sleep onset and sleep offset provided by the software. We used a similar process with the iAide2, using iAide2 software (version 7.0). We analyzed 64 nights and evaluated the agreement between the iAide2 and the MW8 for sleep duration and TST based on intraclass correlation coefficients (ICCs). ResultsThe absolute ICCs (2-way mixed effects, absolute agreement, single measurement) for sleep duration (0.69, 95% CI –0.07 to 0.91) and TST (0.56, 95% CI –0.07 to 0.82) were moderate. The consistency ICC (2-way mixed effects, consistency, single measurement) was excellent for sleep duration (0.91, 95% CI 0.86-0.95) and moderate for TST (0.78, 95% CI 0.67-0.86). We determined a simple calibration approach. After calibration, the ICCs improved to 0.96 (95% CI 0.94-0.98) for sleep duration and 0.82 (95% CI 0.71-0.88) for TST. The results were not sensitive to the specific participants included, with an ICC range of 0.96-0.97 for sleep duration and 0.79-0.87 for TST when applying our calibration equation to data removing one participant at a time and 0.96-0.97 for sleep duration and 0.79-0.86 for TST when recalibrating while removing one participant at a time. ConclusionsThe measurement errors of the uncalibrated iAide2 for both sleep duration and TST seem too large for them to be useful as absolute measurements, though they could be useful as relative measurements. The measurement errors after calibration are low, and the calibration approach is general and robust, validating the use of iAide2’s sleep measurement functions alongside its other features in physical activity research.https://formative.jmir.org/2025/1/e63529
spellingShingle Mari Waki
Ryohei Nakada
Kayo Waki
Yuki Ban
Ryo Suzuki
Toshimasa Yamauchi
Masaomi Nangaku
Kazuhiko Ohe
Validation of Sleep Measurements of an Actigraphy Watch: Instrument Validation Study
JMIR Formative Research
title Validation of Sleep Measurements of an Actigraphy Watch: Instrument Validation Study
title_full Validation of Sleep Measurements of an Actigraphy Watch: Instrument Validation Study
title_fullStr Validation of Sleep Measurements of an Actigraphy Watch: Instrument Validation Study
title_full_unstemmed Validation of Sleep Measurements of an Actigraphy Watch: Instrument Validation Study
title_short Validation of Sleep Measurements of an Actigraphy Watch: Instrument Validation Study
title_sort validation of sleep measurements of an actigraphy watch instrument validation study
url https://formative.jmir.org/2025/1/e63529
work_keys_str_mv AT mariwaki validationofsleepmeasurementsofanactigraphywatchinstrumentvalidationstudy
AT ryoheinakada validationofsleepmeasurementsofanactigraphywatchinstrumentvalidationstudy
AT kayowaki validationofsleepmeasurementsofanactigraphywatchinstrumentvalidationstudy
AT yukiban validationofsleepmeasurementsofanactigraphywatchinstrumentvalidationstudy
AT ryosuzuki validationofsleepmeasurementsofanactigraphywatchinstrumentvalidationstudy
AT toshimasayamauchi validationofsleepmeasurementsofanactigraphywatchinstrumentvalidationstudy
AT masaominangaku validationofsleepmeasurementsofanactigraphywatchinstrumentvalidationstudy
AT kazuhikoohe validationofsleepmeasurementsofanactigraphywatchinstrumentvalidationstudy