Experimental Research on the Control Method of Suction Refrigerant Quality for Wet Compression Refrigeration System

Incomplete wet compression can sharply reduce the discharge temperature of compressors. However, the challenge of the application is how to control the real-time suction refrigerant quality of compressor within the appropriate range. A method using quasi saturation isentropic compression discharge...

Full description

Saved in:
Bibliographic Details
Main Authors: Wang Chao, Tao Leren, Yang Lihui, Yu Zhongyang, Shen Bingjie
Format: Article
Language:zho
Published: Journal of Refrigeration Magazines Agency Co., Ltd. 2017-01-01
Series:Zhileng xuebao
Subjects:
Online Access:http://www.zhilengxuebao.com/thesisDetails#10.3969/j.issn.0253-4339.2017.02.034
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1850027132780019712
author Wang Chao
Tao Leren
Yang Lihui
Yu Zhongyang
Shen Bingjie
author_facet Wang Chao
Tao Leren
Yang Lihui
Yu Zhongyang
Shen Bingjie
author_sort Wang Chao
collection DOAJ
description Incomplete wet compression can sharply reduce the discharge temperature of compressors. However, the challenge of the application is how to control the real-time suction refrigerant quality of compressor within the appropriate range. A method using quasi saturation isentropic compression discharge temperature (QSICDT) to control suction refrigerant quality of compressor was proposed in the paper. The performance change of refrigeration system with R22, R32, R134a and R410A is theoretically analyzed under AHRI (air-conditioning heating and refrigeration institute) air conditioning and refrigeration applications when this method is used to control the suction refrigerant with a small liquid, and the method is verified by R32 experimental data. The results show that using QSICDT can control compressor suction with a small amount of liquid refrigerant; the capacity and COP all can reach the maximum for wet compression refrigeration system with R32 by using QSICDT to control suction refrigerant quality at 0.96 to 1.
format Article
id doaj-art-1ea541e9c1bc4f2c9fe6ebcfff4a8d8f
institution DOAJ
issn 0253-4339
language zho
publishDate 2017-01-01
publisher Journal of Refrigeration Magazines Agency Co., Ltd.
record_format Article
series Zhileng xuebao
spelling doaj-art-1ea541e9c1bc4f2c9fe6ebcfff4a8d8f2025-08-20T03:00:19ZzhoJournal of Refrigeration Magazines Agency Co., Ltd.Zhileng xuebao0253-43392017-01-013866515345Experimental Research on the Control Method of Suction Refrigerant Quality for Wet Compression Refrigeration SystemWang ChaoTao LerenYang LihuiYu ZhongyangShen BingjieIncomplete wet compression can sharply reduce the discharge temperature of compressors. However, the challenge of the application is how to control the real-time suction refrigerant quality of compressor within the appropriate range. A method using quasi saturation isentropic compression discharge temperature (QSICDT) to control suction refrigerant quality of compressor was proposed in the paper. The performance change of refrigeration system with R22, R32, R134a and R410A is theoretically analyzed under AHRI (air-conditioning heating and refrigeration institute) air conditioning and refrigeration applications when this method is used to control the suction refrigerant with a small liquid, and the method is verified by R32 experimental data. The results show that using QSICDT can control compressor suction with a small amount of liquid refrigerant; the capacity and COP all can reach the maximum for wet compression refrigeration system with R32 by using QSICDT to control suction refrigerant quality at 0.96 to 1.http://www.zhilengxuebao.com/thesisDetails#10.3969/j.issn.0253-4339.2017.02.034wet compressionsuction refrigerant qualitydischarge temperatureexperimental research
spellingShingle Wang Chao
Tao Leren
Yang Lihui
Yu Zhongyang
Shen Bingjie
Experimental Research on the Control Method of Suction Refrigerant Quality for Wet Compression Refrigeration System
Zhileng xuebao
wet compression
suction refrigerant quality
discharge temperature
experimental research
title Experimental Research on the Control Method of Suction Refrigerant Quality for Wet Compression Refrigeration System
title_full Experimental Research on the Control Method of Suction Refrigerant Quality for Wet Compression Refrigeration System
title_fullStr Experimental Research on the Control Method of Suction Refrigerant Quality for Wet Compression Refrigeration System
title_full_unstemmed Experimental Research on the Control Method of Suction Refrigerant Quality for Wet Compression Refrigeration System
title_short Experimental Research on the Control Method of Suction Refrigerant Quality for Wet Compression Refrigeration System
title_sort experimental research on the control method of suction refrigerant quality for wet compression refrigeration system
topic wet compression
suction refrigerant quality
discharge temperature
experimental research
url http://www.zhilengxuebao.com/thesisDetails#10.3969/j.issn.0253-4339.2017.02.034
work_keys_str_mv AT wangchao experimentalresearchonthecontrolmethodofsuctionrefrigerantqualityforwetcompressionrefrigerationsystem
AT taoleren experimentalresearchonthecontrolmethodofsuctionrefrigerantqualityforwetcompressionrefrigerationsystem
AT yanglihui experimentalresearchonthecontrolmethodofsuctionrefrigerantqualityforwetcompressionrefrigerationsystem
AT yuzhongyang experimentalresearchonthecontrolmethodofsuctionrefrigerantqualityforwetcompressionrefrigerationsystem
AT shenbingjie experimentalresearchonthecontrolmethodofsuctionrefrigerantqualityforwetcompressionrefrigerationsystem