X射线衍射法残余应力检测的误差影响因素分析

The errors of DST-17 stress meter were analyzed by using compared with standard sample.The experimental results indicated that the number of angles has little influence on the fluctuation of measurement errors,but the measurement errors decrease slightly and finally tend to be stable with the increa...

Full description

Saved in:
Bibliographic Details
Main Authors: 王贺权, 张艳聪, 刘元元
Format: Article
Language:zho
Published: Editorial Office of Journal of Mechanical Strength 2021-01-01
Series:Jixie qiangdu
Online Access:http://www.jxqd.net.cn/thesisDetails#10.16579/j.issn.1001.9669.2021.01.013
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1841535838114021376
author 王贺权
张艳聪
刘元元
author_facet 王贺权
张艳聪
刘元元
author_sort 王贺权
collection DOAJ
description The errors of DST-17 stress meter were analyzed by using compared with standard sample.The experimental results indicated that the number of angles has little influence on the fluctuation of measurement errors,but the measurement errors decrease slightly and finally tend to be stable with the increase of the number of angles.However,the diameter of collimating tube has obvious influence on measurement error of residual stress.The measurement error and error fluctuation of 1 mm diameter collimating tube are large.The measurement error of 2 mm diameter collimating tube is basically the same as that of 3 mm diameter collimating tube.The measurement error of SDD detector is smaller than that of linear array detector.The type of detector has little effect on the error fluctuation.
format Article
id doaj-art-1d61fd6a5b9e4cc38b1d95ecb1c55773
institution Kabale University
issn 1001-9669
language zho
publishDate 2021-01-01
publisher Editorial Office of Journal of Mechanical Strength
record_format Article
series Jixie qiangdu
spelling doaj-art-1d61fd6a5b9e4cc38b1d95ecb1c557732025-01-15T02:26:34ZzhoEditorial Office of Journal of Mechanical StrengthJixie qiangdu1001-96692021-01-01909430609811X射线衍射法残余应力检测的误差影响因素分析王贺权张艳聪刘元元The errors of DST-17 stress meter were analyzed by using compared with standard sample.The experimental results indicated that the number of angles has little influence on the fluctuation of measurement errors,but the measurement errors decrease slightly and finally tend to be stable with the increase of the number of angles.However,the diameter of collimating tube has obvious influence on measurement error of residual stress.The measurement error and error fluctuation of 1 mm diameter collimating tube are large.The measurement error of 2 mm diameter collimating tube is basically the same as that of 3 mm diameter collimating tube.The measurement error of SDD detector is smaller than that of linear array detector.The type of detector has little effect on the error fluctuation.http://www.jxqd.net.cn/thesisDetails#10.16579/j.issn.1001.9669.2021.01.013
spellingShingle 王贺权
张艳聪
刘元元
X射线衍射法残余应力检测的误差影响因素分析
Jixie qiangdu
title X射线衍射法残余应力检测的误差影响因素分析
title_full X射线衍射法残余应力检测的误差影响因素分析
title_fullStr X射线衍射法残余应力检测的误差影响因素分析
title_full_unstemmed X射线衍射法残余应力检测的误差影响因素分析
title_short X射线衍射法残余应力检测的误差影响因素分析
title_sort x射线衍射法残余应力检测的误差影响因素分析
url http://www.jxqd.net.cn/thesisDetails#10.16579/j.issn.1001.9669.2021.01.013
work_keys_str_mv AT wánghèquán xshèxiànyǎnshèfǎcányúyīnglìjiǎncèdewùchàyǐngxiǎngyīnsùfēnxī
AT zhāngyàncōng xshèxiànyǎnshèfǎcányúyīnglìjiǎncèdewùchàyǐngxiǎngyīnsùfēnxī
AT liúyuányuán xshèxiànyǎnshèfǎcányúyīnglìjiǎncèdewùchàyǐngxiǎngyīnsùfēnxī