Study of STATCOM Used for Governing the Electric Arc Furnaces
The extensive application of EAF in the metallurgical industry has caused a series of power quality problems. According to the characteristics of EAF, combining with the quick response and good voltage and current characteristics of STATCOM device, this paper adopts STATCOM voltage and current doubl...
Saved in:
| Main Authors: | , , |
|---|---|
| Format: | Article |
| Language: | zho |
| Published: |
Editorial Office of Control and Information Technology
2011-01-01
|
| Series: | Kongzhi Yu Xinxi Jishu |
| Subjects: | |
| Online Access: | http://ctet.csrzic.com/thesisDetails#10.13889/j.issn.2095-3631.2011.04.007 |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
| _version_ | 1849224780715130880 |
|---|---|
| author | 刘华东 王卫安 黄燕艳 |
| author_facet | 刘华东 王卫安 黄燕艳 |
| author_sort | 刘华东 |
| collection | DOAJ |
| description | The extensive application of EAF in the metallurgical industry has caused a series of power quality problems. According to the characteristics of EAF, combining with the quick response and good voltage and current characteristics of STATCOM device, this paper adopts STATCOM voltage and current double closed-loop control strategy to restrain the voltage flicker caused by EAF. Simulation and experimental results show that the STATCOM voltage and current double closed-loop strategy used for compensating EAF is feasible and effective. |
| format | Article |
| id | doaj-art-1d16f9fb2a6c40eb811f1d9b0fa6f7cd |
| institution | Kabale University |
| issn | 2096-5427 |
| language | zho |
| publishDate | 2011-01-01 |
| publisher | Editorial Office of Control and Information Technology |
| record_format | Article |
| series | Kongzhi Yu Xinxi Jishu |
| spelling | doaj-art-1d16f9fb2a6c40eb811f1d9b0fa6f7cd2025-08-25T06:52:37ZzhoEditorial Office of Control and Information TechnologyKongzhi Yu Xinxi Jishu2096-54272011-01-01656982338380Study of STATCOM Used for Governing the Electric Arc Furnaces刘华东王卫安黄燕艳The extensive application of EAF in the metallurgical industry has caused a series of power quality problems. According to the characteristics of EAF, combining with the quick response and good voltage and current characteristics of STATCOM device, this paper adopts STATCOM voltage and current double closed-loop control strategy to restrain the voltage flicker caused by EAF. Simulation and experimental results show that the STATCOM voltage and current double closed-loop strategy used for compensating EAF is feasible and effective.http://ctet.csrzic.com/thesisDetails#10.13889/j.issn.2095-3631.2011.04.007power qualitySTATCOMelectric arc furnace (EAF)flickerdouble closed-loop control |
| spellingShingle | 刘华东 王卫安 黄燕艳 Study of STATCOM Used for Governing the Electric Arc Furnaces Kongzhi Yu Xinxi Jishu power quality STATCOM electric arc furnace (EAF) flicker double closed-loop control |
| title | Study of STATCOM Used for Governing the Electric Arc Furnaces |
| title_full | Study of STATCOM Used for Governing the Electric Arc Furnaces |
| title_fullStr | Study of STATCOM Used for Governing the Electric Arc Furnaces |
| title_full_unstemmed | Study of STATCOM Used for Governing the Electric Arc Furnaces |
| title_short | Study of STATCOM Used for Governing the Electric Arc Furnaces |
| title_sort | study of statcom used for governing the electric arc furnaces |
| topic | power quality STATCOM electric arc furnace (EAF) flicker double closed-loop control |
| url | http://ctet.csrzic.com/thesisDetails#10.13889/j.issn.2095-3631.2011.04.007 |
| work_keys_str_mv | AT liúhuádōng studyofstatcomusedforgoverningtheelectricarcfurnaces AT wángwèiān studyofstatcomusedforgoverningtheelectricarcfurnaces AT huángyànyàn studyofstatcomusedforgoverningtheelectricarcfurnaces |