Study of STATCOM Used for Governing the Electric Arc Furnaces

The extensive application of EAF in the metallurgical industry has caused a series of power quality problems. According to the characteristics of EAF, combining with the quick response and good voltage and current characteristics of STATCOM device, this paper adopts STATCOM voltage and current doubl...

Full description

Saved in:
Bibliographic Details
Main Authors: 刘华东, 王卫安, 黄燕艳
Format: Article
Language:zho
Published: Editorial Office of Control and Information Technology 2011-01-01
Series:Kongzhi Yu Xinxi Jishu
Subjects:
Online Access:http://ctet.csrzic.com/thesisDetails#10.13889/j.issn.2095-3631.2011.04.007
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849224780715130880
author 刘华东
王卫安
黄燕艳
author_facet 刘华东
王卫安
黄燕艳
author_sort 刘华东
collection DOAJ
description The extensive application of EAF in the metallurgical industry has caused a series of power quality problems. According to the characteristics of EAF, combining with the quick response and good voltage and current characteristics of STATCOM device, this paper adopts STATCOM voltage and current double closed-loop control strategy to restrain the voltage flicker caused by EAF. Simulation and experimental results show that the STATCOM voltage and current double closed-loop strategy used for compensating EAF is feasible and effective.
format Article
id doaj-art-1d16f9fb2a6c40eb811f1d9b0fa6f7cd
institution Kabale University
issn 2096-5427
language zho
publishDate 2011-01-01
publisher Editorial Office of Control and Information Technology
record_format Article
series Kongzhi Yu Xinxi Jishu
spelling doaj-art-1d16f9fb2a6c40eb811f1d9b0fa6f7cd2025-08-25T06:52:37ZzhoEditorial Office of Control and Information TechnologyKongzhi Yu Xinxi Jishu2096-54272011-01-01656982338380Study of STATCOM Used for Governing the Electric Arc Furnaces刘华东王卫安黄燕艳The extensive application of EAF in the metallurgical industry has caused a series of power quality problems. According to the characteristics of EAF, combining with the quick response and good voltage and current characteristics of STATCOM device, this paper adopts STATCOM voltage and current double closed-loop control strategy to restrain the voltage flicker caused by EAF. Simulation and experimental results show that the STATCOM voltage and current double closed-loop strategy used for compensating EAF is feasible and effective.http://ctet.csrzic.com/thesisDetails#10.13889/j.issn.2095-3631.2011.04.007power qualitySTATCOMelectric arc furnace (EAF)flickerdouble closed-loop control
spellingShingle 刘华东
王卫安
黄燕艳
Study of STATCOM Used for Governing the Electric Arc Furnaces
Kongzhi Yu Xinxi Jishu
power quality
STATCOM
electric arc furnace (EAF)
flicker
double closed-loop control
title Study of STATCOM Used for Governing the Electric Arc Furnaces
title_full Study of STATCOM Used for Governing the Electric Arc Furnaces
title_fullStr Study of STATCOM Used for Governing the Electric Arc Furnaces
title_full_unstemmed Study of STATCOM Used for Governing the Electric Arc Furnaces
title_short Study of STATCOM Used for Governing the Electric Arc Furnaces
title_sort study of statcom used for governing the electric arc furnaces
topic power quality
STATCOM
electric arc furnace (EAF)
flicker
double closed-loop control
url http://ctet.csrzic.com/thesisDetails#10.13889/j.issn.2095-3631.2011.04.007
work_keys_str_mv AT liúhuádōng studyofstatcomusedforgoverningtheelectricarcfurnaces
AT wángwèiān studyofstatcomusedforgoverningtheelectricarcfurnaces
AT huángyànyàn studyofstatcomusedforgoverningtheelectricarcfurnaces