Effect of curing temperature freeze-thaw failure mechanism and damage model of equal-strength air-entrained concrete.

The Belt and Road strategy has significantly advanced the scale of infrastructure construction in the Qinghai-Tibet Plateau permafrost area. Consequently, this demands higher requirements on the strength and frost resistance of concrete (FRC) cured under low-temperature and negative-temperature cond...

Full description

Saved in:
Bibliographic Details
Main Authors: YongHe Liu, Bo Yang, Aojun Guo
Format: Article
Language:English
Published: Public Library of Science (PLoS) 2024-01-01
Series:PLoS ONE
Online Access:https://doi.org/10.1371/journal.pone.0312890
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1841555506156535808
author YongHe Liu
Bo Yang
Aojun Guo
author_facet YongHe Liu
Bo Yang
Aojun Guo
author_sort YongHe Liu
collection DOAJ
description The Belt and Road strategy has significantly advanced the scale of infrastructure construction in the Qinghai-Tibet Plateau permafrost area. Consequently, this demands higher requirements on the strength and frost resistance of concrete (FRC) cured under low-temperature and negative-temperature conditions. Accordingly, in this study, tests on the mechanical properties and FRC were conducted under standard curing, 5 °C curing, and -3 °C curing conditions. The pore structure characteristics of concrete subjected to freeze-thaw (F-T) damage (FTD) under different curing methods were analyzed using nuclear magnetic resonance. The study results show that when the air content is constant, the compressive strength of concrete (CSC) tends to decrease with the curing temperature. Moreover, the occurrence of an age lag phenomenon is evident. The compressive strength of concrete cured under standard curing for 28-d was comparable to that achieved by concrete cured at 5 °C curing for 56-d and at -3 °C curing for 84-d. Under the same curing conditions, the CSC decreases with increasing air content. Observations revealed that with the air content in the concrete set at 0.08%, the material's compressive strength was at its minimum. As the number of F-T cycles increases, the concrete transverse relaxation time (T2) curve shifts to the right, and the proportion of both harmful and multi-harmful pores increases. Based on the same CSC under different curing methods, the FRC under 5 °C curing and -3 °C curing conditions is considerably lower than that under standard curing conditions. Moreover, the FRC exhibits an increasing and then a decreasing trend with increasing air content. Concrete exhibits the best frost resistance when the air content is 3.6%. It was established that an optimal range exists for air content in concrete. If the air content is too low, there is only a slight improvement in the FRC. Conversely, if the air content was excessively high, it leads to a significant decrease in frost resistance. Further, this study establishes an FTD model for concrete under 5 °C curing and -3 °C curing conditions considering the compressive strength factors of concrete under standard curing conditions for 28-d. This study is anticipated to be used as reference for determining the FRC cured under different temperatures.
format Article
id doaj-art-16cfd92e07b442ccbd85f21c23ec14a3
institution Kabale University
issn 1932-6203
language English
publishDate 2024-01-01
publisher Public Library of Science (PLoS)
record_format Article
series PLoS ONE
spelling doaj-art-16cfd92e07b442ccbd85f21c23ec14a32025-01-08T05:32:30ZengPublic Library of Science (PLoS)PLoS ONE1932-62032024-01-011912e031289010.1371/journal.pone.0312890Effect of curing temperature freeze-thaw failure mechanism and damage model of equal-strength air-entrained concrete.YongHe LiuBo YangAojun GuoThe Belt and Road strategy has significantly advanced the scale of infrastructure construction in the Qinghai-Tibet Plateau permafrost area. Consequently, this demands higher requirements on the strength and frost resistance of concrete (FRC) cured under low-temperature and negative-temperature conditions. Accordingly, in this study, tests on the mechanical properties and FRC were conducted under standard curing, 5 °C curing, and -3 °C curing conditions. The pore structure characteristics of concrete subjected to freeze-thaw (F-T) damage (FTD) under different curing methods were analyzed using nuclear magnetic resonance. The study results show that when the air content is constant, the compressive strength of concrete (CSC) tends to decrease with the curing temperature. Moreover, the occurrence of an age lag phenomenon is evident. The compressive strength of concrete cured under standard curing for 28-d was comparable to that achieved by concrete cured at 5 °C curing for 56-d and at -3 °C curing for 84-d. Under the same curing conditions, the CSC decreases with increasing air content. Observations revealed that with the air content in the concrete set at 0.08%, the material's compressive strength was at its minimum. As the number of F-T cycles increases, the concrete transverse relaxation time (T2) curve shifts to the right, and the proportion of both harmful and multi-harmful pores increases. Based on the same CSC under different curing methods, the FRC under 5 °C curing and -3 °C curing conditions is considerably lower than that under standard curing conditions. Moreover, the FRC exhibits an increasing and then a decreasing trend with increasing air content. Concrete exhibits the best frost resistance when the air content is 3.6%. It was established that an optimal range exists for air content in concrete. If the air content is too low, there is only a slight improvement in the FRC. Conversely, if the air content was excessively high, it leads to a significant decrease in frost resistance. Further, this study establishes an FTD model for concrete under 5 °C curing and -3 °C curing conditions considering the compressive strength factors of concrete under standard curing conditions for 28-d. This study is anticipated to be used as reference for determining the FRC cured under different temperatures.https://doi.org/10.1371/journal.pone.0312890
spellingShingle YongHe Liu
Bo Yang
Aojun Guo
Effect of curing temperature freeze-thaw failure mechanism and damage model of equal-strength air-entrained concrete.
PLoS ONE
title Effect of curing temperature freeze-thaw failure mechanism and damage model of equal-strength air-entrained concrete.
title_full Effect of curing temperature freeze-thaw failure mechanism and damage model of equal-strength air-entrained concrete.
title_fullStr Effect of curing temperature freeze-thaw failure mechanism and damage model of equal-strength air-entrained concrete.
title_full_unstemmed Effect of curing temperature freeze-thaw failure mechanism and damage model of equal-strength air-entrained concrete.
title_short Effect of curing temperature freeze-thaw failure mechanism and damage model of equal-strength air-entrained concrete.
title_sort effect of curing temperature freeze thaw failure mechanism and damage model of equal strength air entrained concrete
url https://doi.org/10.1371/journal.pone.0312890
work_keys_str_mv AT yongheliu effectofcuringtemperaturefreezethawfailuremechanismanddamagemodelofequalstrengthairentrainedconcrete
AT boyang effectofcuringtemperaturefreezethawfailuremechanismanddamagemodelofequalstrengthairentrainedconcrete
AT aojunguo effectofcuringtemperaturefreezethawfailuremechanismanddamagemodelofequalstrengthairentrainedconcrete