IN VITRO EVALUATION OF THE RESISTANCE OF THREE DIFFERENT POST SYSTEMS AGAINST FUNCTIONAL FORCES

Background: In order to ensure sufficient resistance against functional forces for dentin, which is severely weakened by excessive material loss in single-root single-canal teeth with previous root canal treatment, maximum retention and resistance must be the target. The main purpose of this study...

Full description

Saved in:
Bibliographic Details
Main Author: Mustafa Kocacıklı
Format: Article
Language:English
Published: Selcuk University Press 2023-04-01
Series:Selcuk Dental Journal
Subjects:
Online Access:https://dergipark.org.tr/tr/download/article-file/2902810
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1841561979256307712
author Mustafa Kocacıklı
author_facet Mustafa Kocacıklı
author_sort Mustafa Kocacıklı
collection DOAJ
description Background: In order to ensure sufficient resistance against functional forces for dentin, which is severely weakened by excessive material loss in single-root single-canal teeth with previous root canal treatment, maximum retention and resistance must be the target. The main purpose of this study is to evaluate the shear rupture resistance of the chosen three kinds of posts placed in the teeth roots, against forces that could occur in the replicated mouth. Methods: Freshly extracted 45 teeth -maxillary canin and maxillary central- have been used in our study. Crown portion of the tooth was removed by cutting away 1 mm over the enamel cement junction. Root canals were obturated with a lateral condensation technique using AH-26 and gutta percha sealer. In the study, 15 specimens each from Flexi-Post, Cosmopost, and FRC Postec post systems have been placed in sockets opened down through teeth by using specific burs for each system. A dual cured composite cement (Variolink II low viscosity) was used to bind posts. Prepared specimens were put in steel hose by using acrylic resin. Standardized core material (Coradent) was applied onto top side of posts, and steel hoses were connected to Lloyd test instrument with an angle of 45 degrees. A force with a speed of 1 mm/min was applied to the specimens. Compression shear rupture values were recorded and One Way ANOVA and Kruskall-Wallis variance analyses were conducted for statistical evaluation. Results and Conclusion: Highest values were obtained in Flexi-Post group. FRC Postec was the second, and Cosmopost had the lowest strength values. However, all the systems provided adequate resistance against forces that could occur in the mouth, hence it was concluded that they can be utilized clinically. Key words: posts and cores, post system, prefabricated post systems
format Article
id doaj-art-1319bf347fba455ba705dfcc50f66316
institution Kabale University
issn 2148-7529
language English
publishDate 2023-04-01
publisher Selcuk University Press
record_format Article
series Selcuk Dental Journal
spelling doaj-art-1319bf347fba455ba705dfcc50f663162025-01-03T01:13:46ZengSelcuk University PressSelcuk Dental Journal2148-75292023-04-01101485610.15311/selcukdentj.1238859154IN VITRO EVALUATION OF THE RESISTANCE OF THREE DIFFERENT POST SYSTEMS AGAINST FUNCTIONAL FORCESMustafa Kocacıklı0GAZİ ÜNİVERSİTESİ, DİŞ HEKİMLİĞİ FAKÜLTESİ, DİŞ HEKİMLİĞİ PR.Background: In order to ensure sufficient resistance against functional forces for dentin, which is severely weakened by excessive material loss in single-root single-canal teeth with previous root canal treatment, maximum retention and resistance must be the target. The main purpose of this study is to evaluate the shear rupture resistance of the chosen three kinds of posts placed in the teeth roots, against forces that could occur in the replicated mouth. Methods: Freshly extracted 45 teeth -maxillary canin and maxillary central- have been used in our study. Crown portion of the tooth was removed by cutting away 1 mm over the enamel cement junction. Root canals were obturated with a lateral condensation technique using AH-26 and gutta percha sealer. In the study, 15 specimens each from Flexi-Post, Cosmopost, and FRC Postec post systems have been placed in sockets opened down through teeth by using specific burs for each system. A dual cured composite cement (Variolink II low viscosity) was used to bind posts. Prepared specimens were put in steel hose by using acrylic resin. Standardized core material (Coradent) was applied onto top side of posts, and steel hoses were connected to Lloyd test instrument with an angle of 45 degrees. A force with a speed of 1 mm/min was applied to the specimens. Compression shear rupture values were recorded and One Way ANOVA and Kruskall-Wallis variance analyses were conducted for statistical evaluation. Results and Conclusion: Highest values were obtained in Flexi-Post group. FRC Postec was the second, and Cosmopost had the lowest strength values. However, all the systems provided adequate resistance against forces that could occur in the mouth, hence it was concluded that they can be utilized clinically. Key words: posts and cores, post system, prefabricated post systemshttps://dergipark.org.tr/tr/download/article-file/2902810posts and corespost systemprefabricated post systemspost sistemipost ve corelarprefabrike post sistemleri
spellingShingle Mustafa Kocacıklı
IN VITRO EVALUATION OF THE RESISTANCE OF THREE DIFFERENT POST SYSTEMS AGAINST FUNCTIONAL FORCES
Selcuk Dental Journal
posts and cores
post system
prefabricated post systems
post sistemi
post ve corelar
prefabrike post sistemleri
title IN VITRO EVALUATION OF THE RESISTANCE OF THREE DIFFERENT POST SYSTEMS AGAINST FUNCTIONAL FORCES
title_full IN VITRO EVALUATION OF THE RESISTANCE OF THREE DIFFERENT POST SYSTEMS AGAINST FUNCTIONAL FORCES
title_fullStr IN VITRO EVALUATION OF THE RESISTANCE OF THREE DIFFERENT POST SYSTEMS AGAINST FUNCTIONAL FORCES
title_full_unstemmed IN VITRO EVALUATION OF THE RESISTANCE OF THREE DIFFERENT POST SYSTEMS AGAINST FUNCTIONAL FORCES
title_short IN VITRO EVALUATION OF THE RESISTANCE OF THREE DIFFERENT POST SYSTEMS AGAINST FUNCTIONAL FORCES
title_sort in vitro evaluation of the resistance of three different post systems against functional forces
topic posts and cores
post system
prefabricated post systems
post sistemi
post ve corelar
prefabrike post sistemleri
url https://dergipark.org.tr/tr/download/article-file/2902810
work_keys_str_mv AT mustafakocacıklı invitroevaluationoftheresistanceofthreedifferentpostsystemsagainstfunctionalforces