Temperature Dependence of Hall Mobility AndCarrier Concentration of pb0.55S0.45 Films

Measurements of Hall effect properties at different of annealing temperature have been made on polycrystalline Pb0.55S0.45 films were prepared at room temperature by thermal evaporation technique under high vacuum 4*10-5 torr . The thickness of the film was 2?m .The carrier concentration (n) was obs...

Full description

Saved in:
Bibliographic Details
Main Author: Baghdad Science Journal
Format: Article
Language:English
Published: University of Baghdad, College of Science for Women 2009-03-01
Series:مجلة بغداد للعلوم
Subjects:
Online Access:http://bsj.uobaghdad.edu.iq/index.php/BSJ/article/view/964
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Measurements of Hall effect properties at different of annealing temperature have been made on polycrystalline Pb0.55S0.45 films were prepared at room temperature by thermal evaporation technique under high vacuum 4*10-5 torr . The thickness of the film was 2?m .The carrier concentration (n) was observed to decrease with increasing the annealing temperature. The Hall measurements showed that the charge carriers are electrons (i.e n-type conduction). From the observed dependence on the temperature, it is found that the Hall mobility (µH), drift velocity ( d) carrier life time ( ), mean free path (?) were increased with increasing annealing temperature
ISSN:2078-8665
2411-7986