Effect of a silicon-based sealing agent (GapSeal) on the reverse torque value of the abutment–implant screw

Objective: One major cause of dental implant failure is screw loosening. Silicone sealants have been introduced to reduce the gap between abutments and implants, potentially reducing screw loosening. This study aimed to investigate the effect of using a sealing agent on the reverse torque value (RTV...

Full description

Saved in:
Bibliographic Details
Main Authors: Talayeh Katebi, Soolmaz Heidari, Shima Aalaei
Format: Article
Language:English
Published: Mashhad University of Medical Sciences 2024-12-01
Series:Journal of Dental Materials and Techniques
Subjects:
Online Access:https://jdmt.mums.ac.ir/article_25378_d617c6e8b232a294b6dc23ac38a610ea.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1841527874710929408
author Talayeh Katebi
Soolmaz Heidari
Shima Aalaei
author_facet Talayeh Katebi
Soolmaz Heidari
Shima Aalaei
author_sort Talayeh Katebi
collection DOAJ
description Objective: One major cause of dental implant failure is screw loosening. Silicone sealants have been introduced to reduce the gap between abutments and implants, potentially reducing screw loosening. This study aimed to investigate the effect of using a sealing agent on the reverse torque value (RTV) of abutment–implant screws.Methods: Sixteen implants were divided into experimental and control groups (N=8). GapSeal gel was injected into the fixture's intaglio cavity in the experimental group, while the control group received no injection. The abutments were tightened to the fixtures with a torque of 30 N.cm for all samples. Additionally, full-metal crowns were cemented onto each abutment. The implants underwent axial cyclic loading, with 500,000 cycles at a force of 75 N and a frequency of 2 Hz applied along the longitudinal axis of each sample. The detorque value was measured for all samples using a digital torque meter. Data were analyzed using an independent samples t-test, with significance set at P < 0.05.Results: The mean reversed torque of the study group (18.50 ± 0.71 N.cm) was significantly higher than the control group (11.375 ± 0.43 N.cm; P < 0.001). The difference between the initial tightening torque value (TTV) and RTV (11.50 ± 0.56 N.cm) in the study group was significantly lower than that in the control group (18.62 ± 034 N.cm; P=0.001).Conclusions: The GapSeal gel reduced the torque loss value of the abutment–implant screw and may be recommended in clinical settings to reduce the risk of screw loosening.
format Article
id doaj-art-0ee55b82d0db42ed8f2b71beedf284f2
institution Kabale University
issn 2322-4150
2252-0317
language English
publishDate 2024-12-01
publisher Mashhad University of Medical Sciences
record_format Article
series Journal of Dental Materials and Techniques
spelling doaj-art-0ee55b82d0db42ed8f2b71beedf284f22025-01-15T05:33:18ZengMashhad University of Medical SciencesJournal of Dental Materials and Techniques2322-41502252-03172024-12-0113416917410.22038/jdmt.2024.79955.164025378Effect of a silicon-based sealing agent (GapSeal) on the reverse torque value of the abutment–implant screwTalayeh Katebi0Soolmaz Heidari1Shima Aalaei2Department of Prosthodontics, Student Research Committee, Qazvin University of Medical Sciences, Qazvin, Iran.Department of Operative Dentistry, Dental Caries Prevention Research Center, Qazvin University of Medical Sciences, Qazvin, Iran.Dental Caries Prevention Research Center, Qazvin University of Medical Sciences, Qazvin, Iran.Objective: One major cause of dental implant failure is screw loosening. Silicone sealants have been introduced to reduce the gap between abutments and implants, potentially reducing screw loosening. This study aimed to investigate the effect of using a sealing agent on the reverse torque value (RTV) of abutment–implant screws.Methods: Sixteen implants were divided into experimental and control groups (N=8). GapSeal gel was injected into the fixture's intaglio cavity in the experimental group, while the control group received no injection. The abutments were tightened to the fixtures with a torque of 30 N.cm for all samples. Additionally, full-metal crowns were cemented onto each abutment. The implants underwent axial cyclic loading, with 500,000 cycles at a force of 75 N and a frequency of 2 Hz applied along the longitudinal axis of each sample. The detorque value was measured for all samples using a digital torque meter. Data were analyzed using an independent samples t-test, with significance set at P < 0.05.Results: The mean reversed torque of the study group (18.50 ± 0.71 N.cm) was significantly higher than the control group (11.375 ± 0.43 N.cm; P < 0.001). The difference between the initial tightening torque value (TTV) and RTV (11.50 ± 0.56 N.cm) in the study group was significantly lower than that in the control group (18.62 ± 034 N.cm; P=0.001).Conclusions: The GapSeal gel reduced the torque loss value of the abutment–implant screw and may be recommended in clinical settings to reduce the risk of screw loosening.https://jdmt.mums.ac.ir/article_25378_d617c6e8b232a294b6dc23ac38a610ea.pdfdental abutmentsdental implantsimplant–abutment connectiontorquesiliconessealing agents
spellingShingle Talayeh Katebi
Soolmaz Heidari
Shima Aalaei
Effect of a silicon-based sealing agent (GapSeal) on the reverse torque value of the abutment–implant screw
Journal of Dental Materials and Techniques
dental abutments
dental implants
implant–abutment connection
torque
silicones
sealing agents
title Effect of a silicon-based sealing agent (GapSeal) on the reverse torque value of the abutment–implant screw
title_full Effect of a silicon-based sealing agent (GapSeal) on the reverse torque value of the abutment–implant screw
title_fullStr Effect of a silicon-based sealing agent (GapSeal) on the reverse torque value of the abutment–implant screw
title_full_unstemmed Effect of a silicon-based sealing agent (GapSeal) on the reverse torque value of the abutment–implant screw
title_short Effect of a silicon-based sealing agent (GapSeal) on the reverse torque value of the abutment–implant screw
title_sort effect of a silicon based sealing agent gapseal on the reverse torque value of the abutment implant screw
topic dental abutments
dental implants
implant–abutment connection
torque
silicones
sealing agents
url https://jdmt.mums.ac.ir/article_25378_d617c6e8b232a294b6dc23ac38a610ea.pdf
work_keys_str_mv AT talayehkatebi effectofasiliconbasedsealingagentgapsealonthereversetorquevalueoftheabutmentimplantscrew
AT soolmazheidari effectofasiliconbasedsealingagentgapsealonthereversetorquevalueoftheabutmentimplantscrew
AT shimaaalaei effectofasiliconbasedsealingagentgapsealonthereversetorquevalueoftheabutmentimplantscrew