Effect of a silicon-based sealing agent (GapSeal) on the reverse torque value of the abutment–implant screw
Objective: One major cause of dental implant failure is screw loosening. Silicone sealants have been introduced to reduce the gap between abutments and implants, potentially reducing screw loosening. This study aimed to investigate the effect of using a sealing agent on the reverse torque value (RTV...
Saved in:
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Mashhad University of Medical Sciences
2024-12-01
|
Series: | Journal of Dental Materials and Techniques |
Subjects: | |
Online Access: | https://jdmt.mums.ac.ir/article_25378_d617c6e8b232a294b6dc23ac38a610ea.pdf |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
_version_ | 1841527874710929408 |
---|---|
author | Talayeh Katebi Soolmaz Heidari Shima Aalaei |
author_facet | Talayeh Katebi Soolmaz Heidari Shima Aalaei |
author_sort | Talayeh Katebi |
collection | DOAJ |
description | Objective: One major cause of dental implant failure is screw loosening. Silicone sealants have been introduced to reduce the gap between abutments and implants, potentially reducing screw loosening. This study aimed to investigate the effect of using a sealing agent on the reverse torque value (RTV) of abutment–implant screws.Methods: Sixteen implants were divided into experimental and control groups (N=8). GapSeal gel was injected into the fixture's intaglio cavity in the experimental group, while the control group received no injection. The abutments were tightened to the fixtures with a torque of 30 N.cm for all samples. Additionally, full-metal crowns were cemented onto each abutment. The implants underwent axial cyclic loading, with 500,000 cycles at a force of 75 N and a frequency of 2 Hz applied along the longitudinal axis of each sample. The detorque value was measured for all samples using a digital torque meter. Data were analyzed using an independent samples t-test, with significance set at P < 0.05.Results: The mean reversed torque of the study group (18.50 ± 0.71 N.cm) was significantly higher than the control group (11.375 ± 0.43 N.cm; P < 0.001). The difference between the initial tightening torque value (TTV) and RTV (11.50 ± 0.56 N.cm) in the study group was significantly lower than that in the control group (18.62 ± 034 N.cm; P=0.001).Conclusions: The GapSeal gel reduced the torque loss value of the abutment–implant screw and may be recommended in clinical settings to reduce the risk of screw loosening. |
format | Article |
id | doaj-art-0ee55b82d0db42ed8f2b71beedf284f2 |
institution | Kabale University |
issn | 2322-4150 2252-0317 |
language | English |
publishDate | 2024-12-01 |
publisher | Mashhad University of Medical Sciences |
record_format | Article |
series | Journal of Dental Materials and Techniques |
spelling | doaj-art-0ee55b82d0db42ed8f2b71beedf284f22025-01-15T05:33:18ZengMashhad University of Medical SciencesJournal of Dental Materials and Techniques2322-41502252-03172024-12-0113416917410.22038/jdmt.2024.79955.164025378Effect of a silicon-based sealing agent (GapSeal) on the reverse torque value of the abutment–implant screwTalayeh Katebi0Soolmaz Heidari1Shima Aalaei2Department of Prosthodontics, Student Research Committee, Qazvin University of Medical Sciences, Qazvin, Iran.Department of Operative Dentistry, Dental Caries Prevention Research Center, Qazvin University of Medical Sciences, Qazvin, Iran.Dental Caries Prevention Research Center, Qazvin University of Medical Sciences, Qazvin, Iran.Objective: One major cause of dental implant failure is screw loosening. Silicone sealants have been introduced to reduce the gap between abutments and implants, potentially reducing screw loosening. This study aimed to investigate the effect of using a sealing agent on the reverse torque value (RTV) of abutment–implant screws.Methods: Sixteen implants were divided into experimental and control groups (N=8). GapSeal gel was injected into the fixture's intaglio cavity in the experimental group, while the control group received no injection. The abutments were tightened to the fixtures with a torque of 30 N.cm for all samples. Additionally, full-metal crowns were cemented onto each abutment. The implants underwent axial cyclic loading, with 500,000 cycles at a force of 75 N and a frequency of 2 Hz applied along the longitudinal axis of each sample. The detorque value was measured for all samples using a digital torque meter. Data were analyzed using an independent samples t-test, with significance set at P < 0.05.Results: The mean reversed torque of the study group (18.50 ± 0.71 N.cm) was significantly higher than the control group (11.375 ± 0.43 N.cm; P < 0.001). The difference between the initial tightening torque value (TTV) and RTV (11.50 ± 0.56 N.cm) in the study group was significantly lower than that in the control group (18.62 ± 034 N.cm; P=0.001).Conclusions: The GapSeal gel reduced the torque loss value of the abutment–implant screw and may be recommended in clinical settings to reduce the risk of screw loosening.https://jdmt.mums.ac.ir/article_25378_d617c6e8b232a294b6dc23ac38a610ea.pdfdental abutmentsdental implantsimplant–abutment connectiontorquesiliconessealing agents |
spellingShingle | Talayeh Katebi Soolmaz Heidari Shima Aalaei Effect of a silicon-based sealing agent (GapSeal) on the reverse torque value of the abutment–implant screw Journal of Dental Materials and Techniques dental abutments dental implants implant–abutment connection torque silicones sealing agents |
title | Effect of a silicon-based sealing agent (GapSeal) on the reverse torque value of the abutment–implant screw |
title_full | Effect of a silicon-based sealing agent (GapSeal) on the reverse torque value of the abutment–implant screw |
title_fullStr | Effect of a silicon-based sealing agent (GapSeal) on the reverse torque value of the abutment–implant screw |
title_full_unstemmed | Effect of a silicon-based sealing agent (GapSeal) on the reverse torque value of the abutment–implant screw |
title_short | Effect of a silicon-based sealing agent (GapSeal) on the reverse torque value of the abutment–implant screw |
title_sort | effect of a silicon based sealing agent gapseal on the reverse torque value of the abutment implant screw |
topic | dental abutments dental implants implant–abutment connection torque silicones sealing agents |
url | https://jdmt.mums.ac.ir/article_25378_d617c6e8b232a294b6dc23ac38a610ea.pdf |
work_keys_str_mv | AT talayehkatebi effectofasiliconbasedsealingagentgapsealonthereversetorquevalueoftheabutmentimplantscrew AT soolmazheidari effectofasiliconbasedsealingagentgapsealonthereversetorquevalueoftheabutmentimplantscrew AT shimaaalaei effectofasiliconbasedsealingagentgapsealonthereversetorquevalueoftheabutmentimplantscrew |