Creation and Preclinical Testing of a Spirometer with Extended Functionality

RELEVANCE. We present the results of preclinical testing of an upgraded portable AR­1 gas flow analyzer produced by JSC Krasnogvardeets (Saint Petersburg) in order to create import-substituting technologies and develop practical and scientific spheres of healthcare.THE AIM OF THE STUDY. was to subst...

Full description

Saved in:
Bibliographic Details
Main Authors: V. S. Shabaev, V. A. Onoshko, A. S. Galushko, V. A. Mazurok, I. V. Orazmagomedova, L. G. Vasilyeva, D. A. Aleksandrova
Format: Article
Language:Russian
Published: Sklifosovsky Research Institute for Emergency Medicine, Public Healthcare Institution of Moscow Healthcare Department 2024-10-01
Series:Неотложная медицинская помощь
Subjects:
Online Access:https://www.jnmp.ru/jour/article/view/1940
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849252592509517824
author V. S. Shabaev
V. A. Onoshko
A. S. Galushko
V. A. Mazurok
I. V. Orazmagomedova
L. G. Vasilyeva
D. A. Aleksandrova
author_facet V. S. Shabaev
V. A. Onoshko
A. S. Galushko
V. A. Mazurok
I. V. Orazmagomedova
L. G. Vasilyeva
D. A. Aleksandrova
author_sort V. S. Shabaev
collection DOAJ
description RELEVANCE. We present the results of preclinical testing of an upgraded portable AR­1 gas flow analyzer produced by JSC Krasnogvardeets (Saint Petersburg) in order to create import-substituting technologies and develop practical and scientific spheres of healthcare.THE AIM OF THE STUDY. was to substantiate the possibility of clinical use of the upgraded device, originally intended for testing ventilators and inhalation anesthesia devices, as a monitor of the external respiration apparatus function.MATERIAL AND METHODS. The preclinical study of the upgraded gas flow analyzer was conducted at the V.A. Almazov National Medical Research Center in comparison with devices for conventional (Bellavista 950, Berner Ross Medical, Russia) and high-frequency (IPV-2C, Intrapulmonary Percussive Ventilation, Percussionaire Corporation, USA) mechanical ventilation in volume- and pressure-controlled modes using an artificial lung. The following reflected spirometry parameters were compared: tidal and minute volume under inhalation and exhalation, respiratory rate, maximum and minimum flows, peak and positive end expiratory pressure, fraction of inspired oxygen.RESULTS. A high accuracy of parameter matching shown by the gas flow analyzer and ventilators was demonstrated.CONCLUSION. The upgraded model of the gas flow analyzer can be used clinically as a portable spirometer at the prehospital and hospital stages.
format Article
id doaj-art-0e0c8ded5e5c445ab1eec1012eeec2df
institution Kabale University
issn 2223-9022
2541-8017
language Russian
publishDate 2024-10-01
publisher Sklifosovsky Research Institute for Emergency Medicine, Public Healthcare Institution of Moscow Healthcare Department
record_format Article
series Неотложная медицинская помощь
spelling doaj-art-0e0c8ded5e5c445ab1eec1012eeec2df2025-08-20T03:56:36ZrusSklifosovsky Research Institute for Emergency Medicine, Public Healthcare Institution of Moscow Healthcare DepartmentНеотложная медицинская помощь2223-90222541-80172024-10-0113351452110.23934/2223-9022-2024-13-3-514-521972Creation and Preclinical Testing of a Spirometer with Extended FunctionalityV. S. Shabaev0V. A. Onoshko1A. S. Galushko2V. A. Mazurok3I. V. Orazmagomedova4L. G. Vasilyeva5D. A. Aleksandrova6V.A. Almazov National Medical Research CenterKrasnogvardeetsKrasnogvardeetsV.A. Almazov National Medical Research CenterV.A. Almazov National Medical Research CenterV.A. Almazov National Medical Research CenterV.A. Almazov National Medical Research CenterRELEVANCE. We present the results of preclinical testing of an upgraded portable AR­1 gas flow analyzer produced by JSC Krasnogvardeets (Saint Petersburg) in order to create import-substituting technologies and develop practical and scientific spheres of healthcare.THE AIM OF THE STUDY. was to substantiate the possibility of clinical use of the upgraded device, originally intended for testing ventilators and inhalation anesthesia devices, as a monitor of the external respiration apparatus function.MATERIAL AND METHODS. The preclinical study of the upgraded gas flow analyzer was conducted at the V.A. Almazov National Medical Research Center in comparison with devices for conventional (Bellavista 950, Berner Ross Medical, Russia) and high-frequency (IPV-2C, Intrapulmonary Percussive Ventilation, Percussionaire Corporation, USA) mechanical ventilation in volume- and pressure-controlled modes using an artificial lung. The following reflected spirometry parameters were compared: tidal and minute volume under inhalation and exhalation, respiratory rate, maximum and minimum flows, peak and positive end expiratory pressure, fraction of inspired oxygen.RESULTS. A high accuracy of parameter matching shown by the gas flow analyzer and ventilators was demonstrated.CONCLUSION. The upgraded model of the gas flow analyzer can be used clinically as a portable spirometer at the prehospital and hospital stages.https://www.jnmp.ru/jour/article/view/1940spirometerventilatorverificationgas flow rate
spellingShingle V. S. Shabaev
V. A. Onoshko
A. S. Galushko
V. A. Mazurok
I. V. Orazmagomedova
L. G. Vasilyeva
D. A. Aleksandrova
Creation and Preclinical Testing of a Spirometer with Extended Functionality
Неотложная медицинская помощь
spirometer
ventilator
verification
gas flow rate
title Creation and Preclinical Testing of a Spirometer with Extended Functionality
title_full Creation and Preclinical Testing of a Spirometer with Extended Functionality
title_fullStr Creation and Preclinical Testing of a Spirometer with Extended Functionality
title_full_unstemmed Creation and Preclinical Testing of a Spirometer with Extended Functionality
title_short Creation and Preclinical Testing of a Spirometer with Extended Functionality
title_sort creation and preclinical testing of a spirometer with extended functionality
topic spirometer
ventilator
verification
gas flow rate
url https://www.jnmp.ru/jour/article/view/1940
work_keys_str_mv AT vsshabaev creationandpreclinicaltestingofaspirometerwithextendedfunctionality
AT vaonoshko creationandpreclinicaltestingofaspirometerwithextendedfunctionality
AT asgalushko creationandpreclinicaltestingofaspirometerwithextendedfunctionality
AT vamazurok creationandpreclinicaltestingofaspirometerwithextendedfunctionality
AT ivorazmagomedova creationandpreclinicaltestingofaspirometerwithextendedfunctionality
AT lgvasilyeva creationandpreclinicaltestingofaspirometerwithextendedfunctionality
AT daaleksandrova creationandpreclinicaltestingofaspirometerwithextendedfunctionality